Library › Valvular heart disease › Cardiac auscultation
Cardiac auscultation: heart sounds, murmurs, and maneuvers
The bedside cardiovascular examination in adults: heart sounds, murmurs, dynamic auscultation and its accuracy, the jugular venous pulse, the arterial pulse, and the guideline indications for echocardiography in a patient with a murmur.
Auscultation places a sound in the cardiac cycle and explains it by pressure, flow, and valve motion. Bedside maneuvers that change preload and afterload identify the origin of most systolic murmurs: inspiratory augmentation marks right-sided murmurs, and louder intensity with the Valsalva strain or on standing from a squat marks obstructive hypertrophic cardiomyopathy. Transthoracic echocardiography is the standard initial test for known or suspected valvular heart disease. In the 2020 American College of Cardiology/American Heart Association (ACC/AHA) guideline, the history and examination are correlated with the electrocardiogram, the chest radiograph, and the transthoracic echocardiogram. The 2017 multimodality appropriate use criteria list an unexplained murmur or abnormal heart sounds among the indications for initial imaging of an asymptomatic patient.
Stethoscope technique, auscultatory areas, and patient positions
The diaphragm of the stethoscope, applied firmly, filters low frequencies and transmits high-pitched events: S1, S2, ejection and midsystolic clicks, the opening snap, the murmurs of aortic and mitral regurgitation, and the pericardial friction rub. The bell, applied with just enough pressure to seal the skin, transmits low-pitched events: S3, S4, and the diastolic rumbles of mitral and tricuspid stenosis. Pressing the bell firmly stretches the skin into a diaphragm, and a sound that fades with firm pressure is low pitched. The examination takes place in a quiet room with the chest exposed, because clothing adds friction noise and attenuates soft diastolic murmurs.
The four classic areas describe where valve events are best heard, which is downstream of the valve along the direction of flow and is distinct from the anatomic position of the valve. The aortic area is the right second intercostal space at the sternal border. The pulmonic area is the left second intercostal space. The tricuspid area is the left lower sternal border, in the fourth and fifth spaces. The mitral area is the apex, usually the fifth intercostal space at the midclavicular line. A complete examination also covers the third left intercostal space (Erb point, where aortic regurgitation is often loudest), the right sternal border, both carotid arteries, the axilla, the left infraclavicular area, and the interscapular back. Auscultation proceeds in an inching sequence from base to apex or apex to base, attending first to S1 and S2, then to systole, then to diastole, so that soft extra sounds are not masked by a murmur.
| Position or maneuver | Effect | Findings accentuated |
|---|---|---|
| Supine, torso at 30° to 45° | Standard position for the precordium and the jugular venous pulse | S1, S2 splitting, systolic murmurs, jugular waveform |
| Left lateral decubitus, bell at the apex | Brings the left ventricular apex against the chest wall | Mitral stenosis rumble and opening snap, left-sided S3 and S4, Austin Flint murmur |
| Sitting, leaning forward, breath held in expiration | Brings the base of the heart forward | Aortic regurgitation, pulmonic regurgitation, pericardial friction rub |
| Quiet inspiration | Increases systemic venous return to the right heart | Right-sided murmurs and gallops, physiologic S2 splitting |
| Standing (from squatting or supine) | Reduces venous return and ventricular volume | Obstructive hypertrophic cardiomyopathy murmur; earlier mitral prolapse click |
| Squatting or passive leg raising | Increases venous return; squatting also raises afterload | Most murmurs, including aortic stenosis and regurgitant murmurs; later mitral prolapse click |
| Brief exercise (sit-ups, walking) | Raises heart rate and transmitral flow | Soft mitral stenosis rumble |
Positions and simple maneuvers used to accentuate auscultatory findings.
Timing sounds and murmurs in the cardiac cycle
A sound is timed by its relation to S1 and S2, and S1 and S2 are identified by palpating the carotid artery while listening: S1 immediately precedes the carotid upstroke, and S2 follows its peak. At normal heart rates systole is shorter than diastole, so the shorter interval between two sounds is systole. At rates above about 100 beats/min the two intervals become similar, and timing depends on the carotid pulse. The apical impulse can be used in the same way, because its outward movement begins with S1.
Systole is divided into early, mid, and late thirds, and diastole into the early (protodiastolic) phase of rapid filling, diastasis, and the late (presystolic) phase of atrial contraction. Isovolumic contraction, between mitral closure and aortic opening, is the interval in which an ejection click cannot yet occur. Isovolumic relaxation, between aortic closure and mitral opening, explains why an opening snap, a pericardial knock, a tumor plop, and an S3 all follow A2 by a measurable interval.
The first heart sound: mitral and tricuspid components
S1 is generated by closure of the mitral valve (M1) and, a few milliseconds later, the tricuspid valve (T1), with contributions from the sudden tensing of the chordae and the deceleration of blood. The mitral component is louder and is best heard at the apex; the tricuspid component is heard at the left lower sternal border. Splitting of S1 is normally narrow and is audible in some healthy people at the left lower sternal border.
The intensity of S1 depends mainly on the position of the leaflets at the onset of ventricular contraction. When the leaflets are still widely open at the start of systole, they travel a long distance and close forcefully. A short PR interval, a high left atrial pressure holding the leaflets open in mobile mitral stenosis, and a hyperdynamic circulation therefore produce a loud S1. A long PR interval allows the leaflets to drift toward closure before ventricular systole and softens S1. A calcified immobile mitral valve, poor left ventricular contractility, and acute severe aortic regurgitation also soften S1; in acute aortic regurgitation, high diastolic ventricular pressure closes the mitral valve before systole. Variable intensity from beat to beat indicates a variable atrioventricular relation and occurs in atrial fibrillation and in atrioventricular dissociation, including complete heart block and ventricular tachycardia.
| S1 finding | Mechanism | Causes |
|---|---|---|
| Loud | Leaflets widely open at the onset of systole; forceful contraction | Short PR interval; mobile mitral or tricuspid stenosis; hyperdynamic states (exercise, fever, anemia, thyrotoxicosis); left atrial myxoma |
| Soft | Leaflets partly closed before systole; reduced closing force; poor transmission | Long PR interval; calcified immobile mitral stenosis; severe mitral regurgitation; reduced left ventricular contractility; acute severe aortic regurgitation; obesity, emphysema, pericardial effusion |
| Variable | Changing atrioventricular relation | Atrial fibrillation; complete heart block; ventricular tachycardia with atrioventricular dissociation |
| Widely split | Delayed tricuspid closure | Right bundle branch block; left ventricular pacing; Ebstein anomaly, in which a large late T1 has a "sail" quality |
| Reversed split | Delayed mitral closure | Left bundle branch block; mitral stenosis; left atrial myxoma |
Intensity and splitting of the first heart sound.
An S1 that seems split can be an S4 followed by S1, or S1 followed by an ejection click. An S4 is low pitched, heard with the bell, and fades with firm pressure; an aortic ejection click is high pitched and is heard at both the apex and the base.
The second heart sound: A2, P2, and splitting
S2 consists of aortic closure (A2) followed by pulmonic closure (P2). A2 is heard throughout the precordium. P2 is softer and is normally confined to the left second and third intercostal spaces. A P2 heard at the apex, or a P2 louder than A2 at the base, indicates pulmonary hypertension or a dilated pulmonary artery close to the chest wall, and a palpable P2 accompanies severe pulmonary hypertension. The disease-level findings of pulmonary hypertension, including the right ventricular lift and tricuspid and pulmonic regurgitant murmurs, are described with pulmonary hypertension.
Physiologic splitting. During inspiration, the fall in intrathoracic pressure increases venous return to the right ventricle and lengthens right ventricular ejection. The capacitance of the pulmonary vascular bed also rises. This lengthens the hangout interval, the lag between the fall in right ventricular pressure and the fall in pulmonary artery pressure, and further delays P2. At the same time, pooling of blood in the lungs slightly reduces left ventricular filling and advances A2. The two components separate in inspiration and fuse or nearly fuse in expiration. Splitting is best heard at the left second intercostal space and is often absent in older adults, in whom P2 may be inaudible.
| Pattern | Respiratory behavior | Mechanism | Causes |
|---|---|---|---|
| Physiologic | Split in inspiration, single in expiration | Inspiratory delay of P2 and earlier A2 | Normal |
| Wide (persistent) | Split in both phases, wider in inspiration | Delayed P2 or early A2 | Right bundle branch block; pulmonic stenosis; left ventricular pacing; acute pulmonary embolism; severe mitral regurgitation and ventricular septal defect (early A2 from a shortened left ventricular ejection); idiopathic dilation of the pulmonary artery |
| Fixed | Wide split with little or no respiratory change | Atrial shunt equalizes the respiratory changes in right and left filling; large right ventricular stroke volume lengthens ejection | Atrial septal defect; severe right ventricular failure |
| Paradoxical (reversed) | Split in expiration, single in inspiration | A2 delayed beyond P2 | Left bundle branch block; right ventricular pacing; severe aortic stenosis; obstructive hypertrophic cardiomyopathy; preexcitation through a right-sided accessory pathway |
| Single | No audible split | One component inaudible or the two coincide | Older age; severe aortic stenosis with absent A2; pulmonary atresia or severe pulmonic stenosis with absent P2; Eisenmenger physiology; tetralogy of Fallot |
Splitting of the second heart sound.
Fixed splitting is the auscultatory hallmark of atrial septal defect. Paradoxical splitting reflects delayed left ventricular activation or prolonged ejection; in aortic stenosis a soft or absent A2 producing a single S2 is one of the features that indicate severe obstruction. The electrocardiographic causes of wide and reversed splitting are covered with bundle branch and fascicular blocks.
The intensity of A2 follows the aortic diastolic pressure and the mobility of the leaflets: it is loud in systemic hypertension and with a dilated aortic root, and soft when the aortic leaflets are calcified or immobile. In aortic regurgitation, A2 may be soft from incomplete coaptation.
Third and fourth heart sounds and gallop rhythms
Third heart sound. S3 is a low-pitched sound in early diastole, at the end of the rapid filling phase. It arises when rapid inflow decelerates abruptly as it meets a ventricle that resists further expansion. Two conditions produce it: a large volume of early diastolic inflow, as in mitral regurgitation, a left-to-right shunt, or a high-output state; and a high atrial pressure driving blood into a dilated, noncompliant ventricle, as in systolic heart failure. An S3 is physiologic in children, in young adults up to about 40 years of age, in trained athletes, and in pregnancy. After middle age, a new S3 indicates a pathologic filling pattern. A left ventricular S3 is heard with the bell at the apex in the left lateral decubitus position; a right ventricular S3 is heard at the left lower sternal border or in the subxiphoid area and increases with inspiration.
Fourth heart sound. S4 is a low-pitched presystolic sound produced by a forceful atrial contraction into a ventricle with reduced compliance. It follows the P wave and precedes S1. It occurs with left ventricular hypertrophy from hypertension, aortic stenosis, or hypertrophic cardiomyopathy; during acute ischemia; and with a stiff ventricle in infiltrative disease. Advanced cardiac amyloidosis often lacks an S4 because atrial mechanical function fails. An S4 requires organized atrial contraction and is absent in atrial fibrillation. A palpable presystolic impulse at the apex corresponds to a loud S4. A right ventricular S4 accompanies right ventricular hypertrophy from pulmonic stenosis or pulmonary hypertension.
Summation gallop and quadruple rhythm. At heart rates above about 100 beats/min, diastole shortens. At these rates, or with a long PR interval that moves atrial contraction earlier, the rapid-filling phase overlaps atrial contraction. An S3 and an S4 then fuse into a single loud mid-diastolic summation gallop, which can be louder than either sound alone and separates into two sounds as the rate slows. When both sounds are heard separately, the four sounds produce a quadruple rhythm.
Accuracy and prognostic value. In 90 adults undergoing left heart catheterization, a computer-detected phonocardiographic S3 had a sensitivity of 41% and a specificity of 92% for an elevated left ventricular end-diastolic pressure, and a sensitivity of 52% and a specificity of 87% for a reduced ejection fraction. The S4 was less specific, with specificities of 72% to 80% for the same markers (Marcus 2005). In a retrospective analysis of the Studies of Left Ventricular Dysfunction (SOLVD) treatment trial, an S3, like an elevated jugular venous pressure, was independently associated with heart failure hospitalization, the composite of death or hospitalization for heart failure, and death from pump failure (Drazner 2001). Agreement between examiners on the presence of a gallop is poor. The heart failure with reduced ejection fraction and acute decompensated heart failure pages place the S3 within the assessment of congestion.
Ejection clicks and the midsystolic click of mitral valve prolapse
Ejection clicks. An ejection click is a high-pitched sound in early systole, shortly after S1, produced by the abrupt doming of a stenotic but mobile semilunar valve or by sudden distension of a dilated great artery. An aortic ejection click from a bicuspid valve is heard at both the apex and the base, does not vary with respiration, and precedes the murmur. It disappears as the valve calcifies and loses mobility, so it is characteristic of the younger adult with a bicuspid valve.
A pulmonic ejection click is heard at the left second intercostal space and is the only right-sided event that softens or disappears with inspiration. Inspiration raises right ventricular end-diastolic pressure, and atrial contraction partially domes the pliable pulmonary valve before systole, so less excursion is left for systole. The click is louder with milder valve stenosis and moves closer to S1 as stenosis becomes more severe. Vascular ejection clicks, without valve disease, arise from a dilated aortic root in hypertension or a dilated pulmonary artery in pulmonary hypertension. An ejection click with a systolic murmur in an athlete raises the possibility of a bicuspid aortic valve, a finding sought in the preparticipation examination.
Midsystolic click. In mitral valve prolapse, a redundant leaflet billows into the left atrium during systole and produces a click when the leaflet and its chordae become suddenly taut. The click occurs in mid or late systole, often followed by a late systolic murmur of regurgitation, and multiple clicks can occur. Its timing depends on left ventricular volume: maneuvers that reduce ventricular size (standing, Valsalva strain) bring prolapse earlier in systole, moving the click toward S1 and lengthening the murmur. Maneuvers that enlarge the ventricle (squatting, leg raising, handgrip) delay the click and shorten the murmur. The mitral regurgitation page lists these responses alongside those of chronic mitral regurgitation and hypertrophic cardiomyopathy.
Early diastolic sounds: opening snap, pericardial knock, and tumor plop
Opening snap. In mitral stenosis, the thickened but still mobile anterior leaflet domes abruptly when the high left atrial pressure opens it, producing a high-pitched sound shortly after A2. It is heard best between the apex and the left lower sternal border and radiates widely to the base, where it can be mistaken for a split S2. The interval between A2 and the opening snap varies inversely with left atrial pressure: a higher left atrial pressure reaches left ventricular pressure sooner during isovolumic relaxation, so a short interval indicates more severe stenosis, other factors being equal. Tachycardia and a low aortic pressure also shorten the interval, whereas slow left ventricular relaxation or a raised left ventricular diastolic pressure, as with coexisting aortic regurgitation, lengthens it. Heavy calcification abolishes the snap and softens S1. A tricuspid opening snap, much less common, occurs in rheumatic tricuspid stenosis and increases with inspiration.
Pericardial knock. In constrictive pericarditis, early diastolic filling stops abruptly when the ventricles reach the limit set by the rigid pericardium. The resulting sound occurs earlier and is higher pitched than an S3 and coincides with the nadir of the y descent of the jugular venous pulse. It is present in a minority of patients.
Tumor plop. A pedunculated left atrial myxoma that prolapses into the mitral orifice produces a low-pitched sound in early diastole as it reaches the end of its excursion. In the Lyon series of 112 left atrial myxomas, a plop was heard in 15% of patients and auscultatory findings mimicking mitral valve disease in 53.5% (Pinede 2001). The plop occurs later than an opening snap, and the murmur and plop vary with position. The presentation of cardiac tumors is described with cardiac tumors and masses.
| Sound | Timing after A2 | Pitch and site | Distinguishing features |
|---|---|---|---|
| Split S2 (P2) | Very short | High; left second intercostal space | Varies with respiration; P2 confined to the base unless loud |
| Opening snap | Short; shortens as stenosis worsens | High; apex to left lower sternal border, radiating to the base | Loud S1; mid-diastolic rumble follows; disappears with calcification |
| Pericardial knock | Slightly later than a snap, earlier than S3 | High; left sternal border or apex | Markedly raised jugular venous pressure with a steep y descent; Kussmaul sign |
| Third heart sound | At the end of rapid filling | Low; bell at the apex (left) or lower sternal border (right) | Fades with firm bell pressure; displaced apex in heart failure; normal in the young |
| Tumor plop | Later than an opening snap | Low; apex | Varies with position; may be accompanied by a rumble that mimics mitral stenosis; constitutional symptoms |
Differential diagnosis of sounds in early diastole.
Prosthetic valve sounds
Mechanical valves produce crisp, high-pitched closing clicks, and caged-ball and some tilting-disc valves also produce prominent opening clicks. A soft early systolic ejection murmur across a normally functioning aortic prosthesis is expected. Muffled or absent closing clicks indicate impaired occluder motion. A new diastolic murmur with an aortic prosthesis or a holosystolic apical murmur with a mitral prosthesis indicates regurgitation until shown otherwise. These findings and the imaging that follows them are described under prosthetic valve examination.
Pericardial friction rub
The rub is a high-pitched, scratching or grating sound produced by friction between the inflamed visceral and parietal pericardium. In sinus rhythm it has up to three components, corresponding to atrial systole, ventricular systole, and rapid early diastolic filling; the ventricular systolic component is present in almost all rubs, and a one-component rub can be mistaken for a murmur. It is heard best with the diaphragm at the left lower sternal border while the patient sits forward at end-expiration. It changes from hour to hour, so serial examination raises the yield. A rub that persists while the patient holds the breath is pericardial, which separates it from a pleural rub. A rub can persist with a large effusion. Its clinical context and diagnostic weight are described under acute pericarditis.
Description and grading of murmurs
A murmur is a series of audible vibrations produced by turbulent or high-velocity flow. Turbulence arises from flow through a narrowed orifice, flow into a dilated chamber or vessel, regurgitant flow through an incompetent valve, flow through an abnormal communication, and high flow through a normal valve. The complete description of a murmur specifies seven features:
- Timing: systolic, diastolic, or continuous, and within systole or diastole (early, mid, late, or holo-).
- Shape: crescendo, decrescendo, crescendo-decrescendo (diamond-shaped), or plateau.
- Location: the site of maximal intensity.
- Radiation: the direction of spread, which follows the direction of the jet (carotids in aortic stenosis, axilla in mitral regurgitation from a posterior jet, base and neck from an anteriorly directed jet).
- Pitch: high-pitched murmurs reflect a large pressure gradient (aortic and mitral regurgitation); low-pitched murmurs reflect a small gradient (mitral stenosis rumble).
- Quality: harsh, blowing, rumbling, or musical. A musical (cooing, honking) quality comes from periodic vibration of a structure such as an everted aortic cusp or a calcified leaflet.
- Intensity and response to maneuvers: graded on the scales below, with the change during respiration and loading.
| Grade | Systolic murmur (Levine scale) | Thrill |
|---|---|---|
| 1/6 | Faint; heard only with concentration in a quiet room | No |
| 2/6 | Soft but heard immediately | No |
| 3/6 | Moderately loud | No |
| 4/6 | Loud | Present |
| 5/6 | Very loud; heard with the stethoscope partly off the chest | Present |
| 6/6 | Heard with the stethoscope entirely off the chest | Present |
Grading of systolic murmur intensity. The six-grade scale derives from the 1933 study of systolic murmurs (Freeman 1933); the thrill criterion at grade 4 was added in later teaching. Diastolic murmurs are graded from 1 to 4.
Intensity depends on the velocity and volume of flow, the distance from the stethoscope, and the transmitting tissues. Loudness therefore grades severity poorly. Severe aortic stenosis with low flow, acute severe mitral regurgitation, a large nonrestrictive ventricular septal defect, and torrential tricuspid regurgitation all produce soft or absent murmurs, and obesity, emphysema, and pericardial effusion attenuate all sounds. A grade of 4/6 or louder implies a thrill and is almost always pathologic.
Innocent and flow murmurs in adults
An innocent (functional) murmur arises from flow across normal semilunar valves into the great arteries. In adults it has these features:
- A soft (grade 1/6 or 2/6), short, early-peaking midsystolic ejection murmur at the left sternal border or base.
- Normal S1 and normal physiologic splitting of S2.
- No ejection click, thrill, or diastolic component.
- No change suggesting obstruction with standing or Valsalva strain.
- A normal remainder of the examination, electrocardiogram, and chest radiograph.
Flow murmurs become louder with increased cardiac output in pregnancy, fever, anemia, thyrotoxicosis, exercise, and arteriovenous fistula, and they fade when the high-output state resolves. A narrow anteroposterior chest diameter (straight back syndrome) or pectus excavatum brings the pulmonary outflow closer to the chest wall and produces a louder pulmonic flow murmur.
In older adults, the most common soft early-peaking ejection murmur is aortic sclerosis (leaflet thickening without significant obstruction). It carries a normal S2 and a normal carotid upstroke and is distinguished from stenosis on the aortic stenosis page. Two continuous sounds are also innocent: the cervical venous hum and the mammary souffle, described with the continuous murmurs.
Systolic ejection murmurs
An ejection murmur begins after S1, once the semilunar valve opens, rises to a peak, and ends before the closure sound of the same side. Its crescendo-decrescendo shape follows the ejection velocity curve. Left-sided ejection murmurs are heard at the right upper sternal border and radiate to the neck; right-sided murmurs are heard at the left upper sternal border and increase with inspiration.
Aortic stenosis. The murmur is harsh, crescendo-decrescendo, loudest at the right upper sternal border, and radiates to both carotid arteries. Features that indicate severe obstruction are a murmur that peaks late in systole, a soft or absent A2, and a delayed, small-volume carotid upstroke. In the Gallavardin phenomenon, the high-frequency components radiate to the apex, where the murmur can sound musical and holosystolic and mimic mitral regurgitation. The disease-level examination, including the differential diagnosis of a systolic ejection murmur, is on the aortic stenosis page.
In a systematic review of systolic murmur studies, the most useful findings for ruling in aortic stenosis were a slow rate of rise of the carotid pulse (positive likelihood ratio 2.8 to 130), a mid to late peak of the murmur (8.0 to 101), and a decreased intensity of S2 (3.1 to 50). The absence of radiation to the right carotid artery was the most useful finding for ruling it out (negative likelihood ratio 0.05 to 0.10) (Etchells 1997).
Subvalvular and supravalvular aortic stenosis. A discrete subaortic membrane produces an ejection murmur without an ejection click and often an early diastolic murmur of associated aortic regurgitation. Supravalvular stenosis produces a thrill and a murmur loudest high in the right second intercostal space, with radiation to the right carotid and a higher right arm pressure.
Pulmonic stenosis. The murmur is crescendo-decrescendo at the left second intercostal space, radiates toward the left shoulder and neck, and increases with inspiration. In mild to moderate valvular stenosis it is preceded by a pulmonic ejection click that softens with inspiration. As stenosis becomes more severe, the murmur lengthens, peaks later, and extends beyond A2. P2 becomes softer and later, so S2 splitting widens, and the click moves toward S1. A right ventricular S4, a prominent jugular a wave, and a left parasternal lift then appear. Pulmonic stenosis in adults is most often congenital and may occur with Noonan syndrome. After repair of tetralogy of Fallot, residual right ventricular outflow obstruction and pulmonic regurgitation produce a to-and-fro murmur.
Obstructive hypertrophic cardiomyopathy. The murmur is harsh, crescendo-decrescendo, loudest at the left lower sternal border and apex, and does not radiate to the carotids. A holosystolic apical murmur of mitral regurgitation from systolic anterior motion often accompanies it. It becomes louder with maneuvers that reduce ventricular volume and softer with maneuvers that increase volume or afterload. The carotid pulse is brisk and may be bifid. The disease-level examination and its maneuver table are on the hypertrophic cardiomyopathy page, and the echocardiographic provocation of outflow gradients is described under dynamic outflow obstruction.
Dynamic outflow obstruction outside hypertrophic cardiomyopathy. A small, hyperdynamic left ventricle produces a late-peaking outflow murmur in volume depletion, catecholamine excess, sepsis, Takotsubo syndrome with basal hyperkinesis, and after anterior infarction with a hypercontractile base. The murmur appears or intensifies with inotropes and vasodilators and softens with volume loading.
Aortic stenosis versus hypertrophic cardiomyopathy at the bedside
Valvular aortic stenosis is a fixed obstruction: the murmur follows transvalvular flow, so any maneuver that increases stroke volume makes it louder and any maneuver that reduces stroke volume makes it softer. Obstruction in hypertrophic cardiomyopathy is dynamic: it depends on the size of the left ventricular cavity and the outflow tract. A smaller cavity (less preload, less afterload, more contractility) brings the septum and the mitral leaflet closer and increases obstruction; a larger cavity reduces it. The two lesions therefore respond in opposite directions to preload maneuvers. Afterload maneuvers move both murmurs in the same direction or change them little. A premature beat makes both louder, and the arterial pulse after the premature beat separates them.
| Feature | Valvular aortic stenosis | Obstructive hypertrophic cardiomyopathy | Chronic mitral regurgitation |
|---|---|---|---|
| Site and radiation | Right upper sternal border; carotids | Left lower sternal border and apex; carotids spared | Apex; axilla |
| Shape | Crescendo-decrescendo; peaks later as severity increases | Crescendo-decrescendo; late peaking | Holosystolic plateau |
| Carotid pulse | Slow-rising, small volume (parvus et tardus) in severe disease | Brisk upstroke; may be bifid | Brisk, normal volume |
| S2 | Soft or single; paradoxical split with prolonged ejection | Normal or paradoxical split | Soft S1; S2 may split widely |
| Ejection click | Present with a pliable bicuspid valve | Absent | Absent |
| Valsalva strain | Softer | Louder | Softer |
| Squat to stand | Softer | Louder | Softer or unchanged |
| Stand to squat; passive leg raising | Louder or unchanged | Softer | Louder or unchanged |
| Isometric handgrip | Unchanged or softer | Softer | Louder |
| Beat after a premature contraction | Louder, with a rise in arterial pulse pressure | Louder, with a fall in arterial pulse pressure | Little change |
Bedside comparison of the three common left-sided systolic murmurs.
The post-extrasystolic response is explained by two effects of the long pause: greater filling and potentiated contractility. In fixed stenosis, both increase flow across the valve, so the murmur and the arterial pulse pressure rise together. In dynamic obstruction, the increased contractility narrows the outflow tract further, so the gradient and murmur rise while the stroke volume reaching the aorta, and therefore the pulse pressure, falls. Mitral regurgitation changes little, because the extra forward and regurgitant volumes are distributed between two outlets.
The Valsalva response in hypertrophic cardiomyopathy has an echocardiographic counterpart in the 2024 AHA/ACC guideline: provocation with Valsalva, standing, or exercise is used when the resting gradient is below 50 mm Hg (Ommen 2024).
Holosystolic and late systolic murmurs
A holosystolic murmur begins with S1 and continues to or through S2, because the pressure difference driving the flow exists from the onset of contraction to the end of ejection. Three lesions produce it: mitral regurgitation, tricuspid regurgitation, and ventricular septal defect.
Chronic mitral regurgitation. The murmur is blowing, high pitched, loudest at the apex, and radiates to the axilla and left infrascapular area. A flail posterior leaflet directs the jet anteriorly, so the murmur radiates to the base and neck and can mimic aortic stenosis. It is louder with handgrip and transient arterial occlusion, which raise afterload. A third heart sound in mitral regurgitation reflects a large early diastolic inflow and does not by itself indicate ventricular failure. A short diastolic flow rumble without an opening snap indicates large transmitral flow. Lesion-specific signs and severity clues are on the mitral regurgitation page.
Acute severe mitral regurgitation. When regurgitation enters a small, noncompliant left atrium, atrial pressure rises rapidly toward left ventricular pressure during systole and the gradient collapses in late systole. The murmur is early, decrescendo, often soft, and sometimes absent. A quiet precordium in a patient with pulmonary edema and a hyperdynamic ventricle points to acute mitral regurgitation.
Tricuspid regurgitation. The murmur is holosystolic, is heard at the left lower sternal border and sometimes in the subxiphoid area, and increases during inspiration (the Carvallo sign), because inspiration increases right ventricular volume and regurgitant flow. A large right ventricle can displace the murmur to the apex, where inspiratory augmentation separates it from mitral regurgitation. Associated findings are large jugular v waves, a pulsatile liver, and a right ventricular lift. In torrential regurgitation with near-equal right atrial and ventricular pressures, the murmur may be soft, short, or absent, and the jugular pulse becomes the main sign. In the bedside maneuver study, augmentation with inspiration identified right-sided murmurs with a sensitivity of 100% and a specificity of 88% (Lembo 1988). Disease-level findings are on the right ventricular failure and pulmonary hypertension pages.
Ventricular septal defect. The murmur is harsh and holosystolic at the left lower sternal border, usually with a thrill. Its intensity varies inversely with defect size. A small restrictive defect preserves a large systolic gradient between the ventricles and produces a loud murmur (maladie de Roger), whereas a large nonrestrictive defect with near-equal ventricular pressures produces a softer murmur. A muscular defect that closes during late systole produces a murmur that ends before S2. As pulmonary vascular resistance rises toward Eisenmenger physiology, the left-to-right gradient and the murmur diminish while P2 becomes loud. Mitral regurgitation and ventricular septal defect respond in parallel to all maneuvers (Lembo 1988).
Mitral valve prolapse. A midsystolic click is followed by a late systolic crescendo murmur at the apex. Reduced ventricular volume brings the click and murmur earlier and lengthens the murmur; increased volume delays and shortens them. The murmur becomes holosystolic as regurgitation progresses or a chord ruptures.
| Lesion | Site and radiation | Response to inspiration | Response to handgrip | Associated findings |
|---|---|---|---|---|
| Chronic mitral regurgitation | Apex; axilla (posterior jet) or base and neck (anterior jet) | None or softer | Louder | Soft S1; S3; displaced hyperdynamic apex |
| Acute severe mitral regurgitation | Apex or widely transmitted; often soft | None | Variable | Pulmonary edema; hyperdynamic normal-sized ventricle; early decrescendo murmur |
| Tricuspid regurgitation | Left lower sternal border; subxiphoid | Louder (Carvallo sign) | None | Large v waves; pulsatile liver; right ventricular lift |
| Ventricular septal defect | Left lower sternal border; widely heard | None | Louder | Thrill; louder when small; soft with Eisenmenger physiology |
| Mitral valve prolapse | Apex | None | Click later; murmur shorter | Midsystolic click that moves with volume |
Holosystolic and late systolic murmurs in adults.
Diastolic murmurs
A diastolic murmur indicates heart disease and warrants echocardiography. The two exceptions, the venous hum and the mammary souffle, are continuous murmurs with a diastolic component. Diastolic murmurs fall into two groups. Early diastolic murmurs begin with S2 and arise from semilunar valve regurgitation. Mid-diastolic and presystolic murmurs begin after an interval and arise from atrioventricular valve inflow.
Aortic regurgitation. The murmur is high pitched, blowing, and decrescendo, beginning immediately after A2. It is heard best with the diaphragm at the third or fourth left intercostal space while the patient sits forward at end-expiration. A murmur louder at the right sternal border than at the left suggests dilation of the aortic root as the cause. In chronic severe regurgitation, the murmur lengthens with severity, and a wide pulse pressure, a hyperdynamic displaced apex, and an accompanying systolic flow murmur reflect the large stroke volume. In acute severe aortic regurgitation, left ventricular diastolic pressure rises quickly to aortic pressure, so the murmur is short and soft, the pulse pressure is normal or narrow, and S1 is soft from early mitral closure. Handgrip and transient arterial occlusion make the murmur louder.
The eponymous peripheral signs of chronic aortic regurgitation (the collapsing pulse with its Corrigan, de Musset, Quincke, Müller, Duroziez, Traube, and Hill signs) reflect a large stroke volume with rapid diastolic runoff and are described with the aortic regurgitation examination.
Austin Flint murmur. In severe aortic regurgitation, a low-pitched mid-diastolic or presystolic rumble at the apex is produced by the regurgitant jet impinging on the anterior mitral leaflet and limiting its opening, and by the jet's own turbulence. It mimics mitral stenosis but has no loud S1 and no opening snap. Amyl nitrite, by lowering afterload and the regurgitant volume, softens an Austin Flint murmur and intensifies the rumble of true mitral stenosis.
Pulmonic regurgitation. With pulmonary hypertension, the high pulmonary diastolic pressure produces a high-pitched, blowing, early diastolic decrescendo murmur at the left upper sternal border (the Graham Steell murmur), accompanied by a loud P2. This murmur can be difficult to distinguish from aortic regurgitation; inspiratory augmentation and the absence of peripheral signs favor a pulmonic origin. With normal pulmonary pressure, as after repair of tetralogy of Fallot or pulmonary valvotomy, the murmur is low pitched, begins after a short gap following P2, and is shorter. With severe free regurgitation, it can be short and soft because pulmonary and right ventricular diastolic pressures equalize early.
Mitral stenosis. The murmur is a low-pitched rumble at the apex, heard with the bell in the left lateral decubitus position, after an opening snap and a loud S1. In sinus rhythm, atrial contraction produces presystolic accentuation; atrial fibrillation abolishes it. The duration of the rumble and the persistence of flow throughout diastole reflect severity better than loudness, and a short interval between A2 and the opening snap indicates a high left atrial pressure. A soft rumble becomes audible after brief exercise. The disease is described in full on the mitral stenosis page, including its echocardiographic grading.
Tricuspid stenosis. The rumble is heard at the left lower sternal border, is higher pitched and shorter than that of mitral stenosis, and increases with inspiration. It is almost always rheumatic and accompanies mitral stenosis, so the mitral murmur often masks it. The jugular pulse shows a large a wave and a slow y descent.
Flow rumbles and functional diastolic murmurs. Increased flow across a normal atrioventricular valve produces a short mid-diastolic rumble without an opening snap: across the mitral valve in severe mitral regurgitation, ventricular septal defect, and patent ductus arteriosus, and across the tricuspid valve in atrial septal defect and severe tricuspid regurgitation. The Carey Coombs murmur is a soft mid-diastolic apical murmur of acute rheumatic mitral valvulitis that comes and goes with the carditis. A left atrial myxoma can reproduce the rumble of mitral stenosis.
| Murmur | Timing and shape | Site and position | Distinguishing features |
|---|---|---|---|
| Aortic regurgitation | Early diastolic decrescendo from A2 | Third or fourth left intercostal space (right sternal border with root disease); sitting forward, expiration | Wide pulse pressure in chronic disease; louder with handgrip; short and soft when acute |
| Pulmonic regurgitation with pulmonary hypertension (Graham Steell) | Early diastolic decrescendo from P2 | Left upper sternal border | Loud P2; right ventricular lift; louder with inspiration; no peripheral signs |
| Pulmonic regurgitation with normal pressure | Low-pitched, delayed after P2, short | Left upper sternal border | Repaired tetralogy of Fallot or valvotomy; to-and-fro with outflow murmur |
| Mitral stenosis | Mid-diastolic rumble after an opening snap; presystolic accentuation in sinus rhythm | Apex; bell; left lateral decubitus | Loud S1; duration tracks severity; louder after exercise |
| Austin Flint murmur | Mid-diastolic or presystolic rumble | Apex | Severe aortic regurgitation; no opening snap; softer with amyl nitrite |
| Tricuspid stenosis | Mid-diastolic rumble | Left lower sternal border | Louder with inspiration; large a wave; coexisting mitral stenosis |
| Flow rumble | Short mid-diastolic, no snap | Apex (mitral) or left lower sternal border (tricuspid) | Large shunt or severe regurgitation upstream of the valve |
| Left atrial myxoma | Mid-diastolic rumble with or without a plop | Apex | Changes with position; constitutional symptoms; embolism |
Differential diagnosis of diastolic murmurs in adults.
Continuous and to-and-fro murmurs
A continuous murmur begins in systole and continues through S2 into part or all of diastole. It indicates flow from a higher-pressure to a lower-pressure region throughout the cardiac cycle, usually from an artery to a vein, a cardiac chamber, or the pulmonary artery. A to-and-fro murmur is a different finding: a systolic ejection murmur and a diastolic regurgitant murmur at the same valve, with a pause or change in character at S2, as in combined aortic stenosis and regurgitation.
Patent ductus arteriosus. The murmur is a continuous "machinery" murmur at the left infraclavicular area and left second intercostal space, rising to a peak around S2 and fading in diastole. A large ductus in an adult may produce a wide pulse pressure and an apical flow rumble. As pulmonary vascular resistance rises, the diastolic component shortens and disappears, and in Eisenmenger physiology the murmur may vanish, leaving a loud P2 and differential cyanosis of the feet.
Venous hum. A soft continuous murmur, louder in diastole, is heard above the medial end of the right clavicle with the patient sitting. It is abolished by light pressure over the ipsilateral internal jugular vein, by lying supine, or by turning the head toward the side of the hum. It is common in pregnancy, thyrotoxicosis, and anemia and in patients with dialysis access, and it is innocent.
Mammary souffle. A continuous or systolic murmur over the breast in late pregnancy and lactation arises from increased arterial flow and disappears with firm pressure of the stethoscope.
Arteriovenous fistula. Hemodialysis access and traumatic or iatrogenic fistulas produce a continuous murmur over the site. Large fistulas increase cardiac output and can cause high-output heart failure.
Ruptured sinus of Valsalva aneurysm. Rupture of an aneurysmal aortic sinus, usually into the right ventricle or right atrium, produces the sudden onset of a loud continuous murmur at the lower sternal border, often with a thrill, accompanied by chest pain and acute heart failure. The murmur is louder in diastole than a ductus murmur and is located lower on the precordium.
Coronary arteriovenous fistula. A fistula draining into the right heart or pulmonary artery produces a continuous murmur at an unusual precordial site, often accentuated in diastole when coronary flow is greatest.
Other causes. Aortopulmonary window, collateral arteries in coarctation (heard over the back), pulmonary arteriovenous malformations, and severe peripheral pulmonary artery stenosis produce continuous murmurs.
| Cause | Location | Distinguishing features |
|---|---|---|
| Patent ductus arteriosus | Left infraclavicular, left second intercostal space | Machinery quality; peaks around S2; wide pulse pressure with a large shunt |
| Venous hum | Right supraclavicular | Sitting; abolished by jugular compression or lying supine; innocent |
| Mammary souffle | Over the breast | Late pregnancy and lactation; abolished by firm stethoscope pressure |
| Ruptured sinus of Valsalva aneurysm | Lower left or right sternal border | Sudden onset with chest pain and heart failure; thrill |
| Coronary arteriovenous fistula | Variable; often lower sternal border | Diastolic accentuation; unusual site |
| Systemic arteriovenous fistula | Over the fistula | Dialysis access or prior trauma; high-output state |
| Coarctation collaterals | Interscapular back | Upper-limb hypertension; weak, delayed femoral pulses |
Causes of continuous murmurs in adults.
Dynamic auscultation: physiology of the maneuvers
Bedside maneuvers change preload, afterload, or contractility in predictable directions. Murmurs whose intensity follows flow (aortic and pulmonic stenosis, regurgitant murmurs) move with the change in flow; murmurs of dynamic obstruction move opposite to ventricular size; and the timing of prolapse moves with ventricular volume. The response is judged by comparing several beats before and during the maneuver.
Respiration. Inspiration lowers intrathoracic pressure, increases systemic venous return, and increases right ventricular stroke volume, while left-sided return falls slightly as blood pools in the lungs. Right-sided murmurs and gallops become louder during inspiration and left-sided events become slightly softer or stay unchanged. The pulmonic ejection click is the exception, softening with inspiration. Normal quiet breathing is used, because breath holding at deep inspiration can produce a Valsalva effect that abolishes the inspiratory increase.
Valsalva maneuver. The patient exhales forcefully against a closed glottis, generating an expiratory pressure of about 40 mm Hg for 10 to 15 seconds, or bears down as if straining. In phase I, the rise in intrathoracic pressure transiently raises arterial pressure. In phase II, the strain phase, venous return falls, both ventricles shrink, stroke volume and pulse pressure fall, and heart rate rises. Most murmurs soften during the strain; the murmur of obstructive hypertrophic cardiomyopathy becomes louder, and the click and murmur of mitral prolapse move earlier and lengthen. In phase III, release produces a brief further fall in pressure. In phase IV, venous return recovers and is ejected into a constricted arterial bed, which produces an overshoot of arterial pressure with reflex slowing of the heart.
After release, right-sided murmurs return to baseline within the first few beats, before left-sided murmurs, because venous return reaches the right heart first. A normal arterial pressure response during Valsalva confirms that the maneuver was performed adequately; in heart failure with high filling pressure, the pressure remains elevated during the strain (square-wave response).
Squatting and standing. Rapid squatting from standing compresses the leg veins and increases venous return, and kinking of the femoral and popliteal arteries raises systemic vascular resistance. Both enlarge the left ventricle: the obstructive cardiomyopathy murmur softens, the prolapse click moves later, and murmurs of aortic stenosis and regurgitation become louder or stay unchanged. Standing abruptly from the squat reverses these changes within a few beats. In the bedside study, the squat-to-stand transition was more sensitive for hypertrophic cardiomyopathy than the Valsalva strain (Lembo 1988). Older patients and those with arthritis can perform passive leg raising in place of squatting.
Passive leg raising. Raising both legs to about 45° in a supine patient increases venous return without changing afterload and softens the murmur of obstructive hypertrophic cardiomyopathy.
Isometric handgrip. Sustained gripping raises systemic vascular resistance, arterial pressure, heart rate, and cardiac output. The higher afterload increases the regurgitant fraction across the mitral and aortic valves and the left-to-right shunt across a ventricular septal defect, so those murmurs become louder. The obstructive cardiomyopathy murmur softens, the aortic stenosis murmur is unchanged or softer, and the prolapse click is delayed. The maneuver is unsuitable in patients with myocardial ischemia or uncontrolled hypertension.
Transient arterial occlusion. Blood pressure cuffs on both upper arms are inflated above systolic pressure to raise afterload without the reflex tachycardia of handgrip. Left-sided regurgitant murmurs and ventricular septal defect murmurs become louder.
Amyl nitrite. Inhaled amyl nitrite, a vasodilator, lowers arterial pressure within seconds, followed by reflex tachycardia and increased venous return. Murmurs of aortic stenosis, pulmonic stenosis, obstructive cardiomyopathy, and mitral stenosis become louder, whereas murmurs of mitral regurgitation, ventricular septal defect, aortic regurgitation, and the Austin Flint murmur become softer. It is now seldom used at the bedside.
Post-extrasystolic beat. After a premature beat and compensatory pause, the increased filling and potentiated contractility make ejection murmurs louder, while the murmur of mitral regurgitation changes little. A long cycle in atrial fibrillation produces the same response without provocation.
| Maneuver | Main hemodynamic change | Louder | Softer | Mitral prolapse click |
|---|---|---|---|---|
| Inspiration | Right-sided venous return rises | Right-sided murmurs and gallops | Pulmonic ejection click; left-sided events slightly | No consistent change |
| Valsalva strain | Preload falls in both ventricles | Obstructive hypertrophic cardiomyopathy | Most other murmurs | Earlier; murmur longer |
| Squat to stand | Preload falls abruptly | Obstructive hypertrophic cardiomyopathy | Aortic stenosis; most other murmurs | Earlier; murmur longer |
| Stand to squat | Preload and afterload rise | Aortic stenosis; regurgitant murmurs | Obstructive hypertrophic cardiomyopathy | Later; murmur shorter |
| Passive leg raising | Preload rises | Most murmurs | Obstructive hypertrophic cardiomyopathy | Later; murmur shorter |
| Isometric handgrip | Afterload rises | Mitral and aortic regurgitation; ventricular septal defect | Obstructive hypertrophic cardiomyopathy; aortic stenosis unchanged or softer | Later; murmur shorter |
| Transient arterial occlusion | Afterload rises without tachycardia | Mitral and aortic regurgitation; ventricular septal defect | None characteristic | Later |
| Amyl nitrite | Afterload falls; reflex tachycardia and increased venous return | Aortic and pulmonic stenosis; obstructive hypertrophic cardiomyopathy; mitral stenosis | Mitral and aortic regurgitation; ventricular septal defect; Austin Flint murmur | Earlier; murmur longer |
| Beat after a premature contraction | Filling and contractility rise | Aortic stenosis; obstructive hypertrophic cardiomyopathy | None; mitral regurgitation changes little | Variable |
Physiology and expected responses of the bedside maneuvers used in dynamic auscultation.
Diagnostic accuracy of auscultation and bedside maneuvers
A study of 50 patients with documented systolic murmurs compared all standard bedside maneuvers against an independent diagnosis (Lembo 1988). No single maneuver identified aortic stenosis, which was diagnosed by exclusion; the combination of maneuvers established the origin of most murmurs.
| Target and maneuver response | Sensitivity | Specificity | Positive LR | Negative LR |
|---|---|---|---|---|
| Right-sided murmur: louder with inspiration | 100% | 88% | 8.3 | 0.0 |
| Right-sided murmur: softer with expiration | 100% | 88% | 8.3 | 0.0 |
| Hypertrophic cardiomyopathy: louder with Valsalva strain | 65% | 96% | 16.3 | 0.36 |
| Hypertrophic cardiomyopathy: louder on squat to stand | 95% | 84% | 5.9 | 0.06 |
| Hypertrophic cardiomyopathy: softer on stand to squat | 95% | 85% | 6.3 | 0.06 |
| Hypertrophic cardiomyopathy: softer with passive leg raising | 85% | 91% | 9.4 | 0.16 |
| Hypertrophic cardiomyopathy: softer with handgrip | 85% | 75% | 3.4 | 0.20 |
| Mitral regurgitation or ventricular septal defect: louder with handgrip | 68% | 92% | 8.5 | 0.35 |
| Mitral regurgitation or ventricular septal defect: louder with transient arterial occlusion | 78% | 100% | Not calculable (no false positives) | 0.22 |
| Mitral regurgitation or ventricular septal defect: softer with amyl nitrite | 80% | 90% | 8.0 | 0.22 |
Accuracy of bedside maneuvers for the origin of a systolic murmur in 50 patients with documented systolic murmurs (Lembo 1988). LR, likelihood ratio. Positive LR is sensitivity ÷ (1 − specificity), and negative LR is (1 − sensitivity) ÷ specificity.
Most accuracy studies used cardiologist examiners, and reliability is lower among generalists and trainees. Detection of a systolic murmur had only fair agreement between examiners (kappa 0.30 to 0.48) (Etchells 1997). In a multicenter study of 453 physicians in training, residents recognized 20% of 12 recorded cardiac events, and the number recognized improved little with year of training (Mangione 1997).
| Finding or comparison | Population and reference standard | Result |
|---|---|---|
| Slow rate of rise of the carotid pulse for aortic stenosis | Systematic review of systolic murmur studies | Positive LR 2.8–130 (Etchells 1997) |
| Mid to late peak of the murmur for aortic stenosis | Same review | Positive LR 8.0–101 |
| Decreased S2 for aortic stenosis | Same review | Positive LR 3.1–50 |
| No radiation to the right carotid for aortic stenosis | Same review | Negative LR 0.05–0.10 |
| Phonocardiographic S3 for elevated left ventricular end-diastolic pressure (LVEDP) | 90 adults at left heart catheterization | Sensitivity 41%, specificity 92% (Marcus 2005) |
| Phonocardiographic S4 for elevated LVEDP | Same study | Sensitivity 46%, specificity 80% |
| Auscultation for significant valve disease | 251 asymptomatic adults older than 65 years in primary care; echocardiography | Sensitivity 44%, specificity 69% for at least moderate regurgitation or any stenosis (Gardezi 2018) |
| Cardiologist examination versus hand-carried ultrasound by trained students | 61 patients with cardiac disease; standard echocardiography | Abnormal findings detected: 49% by examination, 75% by ultrasound; lesions causing a diastolic murmur: 16% and 75% (Kobal 2005) |
| Deep-learning digital stethoscope for murmur detection | 962 patients; echocardiography and expert annotation | Sensitivity 76.3%, specificity 91.4% (Chorba 2021) |
| Jugular venous distension at rest or inducible for wedge pressure 18 mm Hg or higher | 52 patients with advanced chronic heart failure | Sensitivity 81%, specificity 80% (Butman 1993) |
| Pulsus paradoxus above 10 mm Hg for tamponade | Patients with a known effusion | Positive LR 3.3; negative LR 0.03 for 10 mm Hg or less (Roy 2007) |
Accuracy of selected findings of the cardiovascular examination. LVEDP, left ventricular end-diastolic pressure; LR, likelihood ratio.
Specific findings in the hands of experienced examiners (a late-peaking murmur with a slow carotid upstroke, an inspiratory increase, a louder murmur on standing) carry high positive likelihood ratios. The presence or absence of a murmur alone has limited value as a screening test, particularly in obese patients and when the examiner is inexperienced.
Post-test probability from bedside maneuvers for systolic murmurs
The calculator applies the likelihood ratios of the maneuver accuracy table to a pretest probability for one lesion group: a right-sided murmur; hypertrophic cardiomyopathy; or mitral regurgitation or ventricular septal defect. Post-test odds equal pretest odds multiplied by the likelihood ratio. A maneuver recorded as not done is left out. The default pretest probability of 50% is illustrative; the pretest probability for a patient comes from the history, the examination, and the clinical setting. A louder murmur with transient arterial occlusion had no false positives in the study, so its positive likelihood ratio is not calculable. The calculator reports that response without a number and leaves it out of the product.
Likelihood ratios from 50 patients with documented systolic murmurs (Lembo 1988), as printed in the accuracy table. Pretest odds = p ÷ (1 − p); post-test odds = pretest odds × LR; post-test probability = odds ÷ (1 + odds). Multiplying several LRs assumes that the maneuver responses are independent. Maneuvers that alter the same loading conditions give correlated responses, so the combined figure is an upper bound on the strength of the evidence, and the single strongest maneuver gives the safer estimate. A negative LR of 0.0 reflects no false negatives in 50 patients. With the default values (hypertrophic cardiomyopathy, pretest probability 50%, louder with Valsalva strain, and louder on squat to stand), the Valsalva response alone gives 94%, and the product of the two LRs (96.2) gives 99%. LR, likelihood ratio.
When a murmur needs echocardiography: guideline indications
The valve guidelines specify when a murmur leads to an echocardiogram. In the 2020 ACC/AHA valvular heart disease guideline, the history and physical findings are correlated with the electrocardiogram, the chest radiograph, and the transthoracic echocardiogram. When the examination and these initial tests are discordant, further testing determines the treatment strategy. The noninvasive options are computed tomography (CT), cardiac magnetic resonance, and stress testing; the invasive options are transesophageal echocardiography and cardiac catheterization (Otto 2021). In patients with a bicuspid aortic valve, the guideline recommends transthoracic echocardiography to assess valve morphology, the severity of stenosis and regurgitation, the aortic root and ascending aorta, and the presence of coarctation.
The 2017 multimodality appropriate use criteria for valvular heart disease list an unexplained murmur or abnormal heart sounds, and a reasonable suspicion of valvular heart disease, among the indications for the initial evaluation of an asymptomatic patient. The criteria map both indications to the 2014 AHA/ACC recommendation for transthoracic echocardiography in the initial evaluation of known or suspected valvular heart disease (Class I, Level of Evidence B) (Doherty 2017; Nishimura 2014). The examination confirms the diagnosis, establishes the cause, determines severity, assesses hemodynamic consequences and prognosis, and informs the timing of intervention. In the asymptomatic older adult, the low sensitivity of auscultation for significant valve disease (Gardezi 2018) supports a low threshold for echocardiography when symptoms, an abnormal electrocardiogram, or an ambiguous examination are present. Once a lesion is found, surveillance intervals follow the stage-based tables of the 2020 guideline described on the aortic stenosis and mitral regurgitation pages.
Point-of-care ultrasound, digital stethoscopes, and phonocardiography
Focused cardiac ultrasound. The 2013 American Society of Echocardiography (ASE) recommendations defined focused cardiac ultrasound as a bedside adjunct to the physical examination that answers a limited set of questions, such as left ventricular size and function, pericardial effusion, and right ventricular enlargement (Spencer 2013). The 2024 ASE nomenclature recommendations defined basic and advanced cardiac point-of-care ultrasound by the scope of the examination and the training of the clinician (Kirkpatrick 2024). In one study, medical students with 18 hours of training using a hand-carried device identified 75% of abnormal findings, compared with 49% for cardiologists performing a physical examination. The students recognized 93% of lesions producing a systolic murmur, compared with 62% for the cardiologists (Kobal 2005). A focused study does not grade valve disease, because severity requires spectral Doppler; a murmur with an abnormal valve on a focused scan leads to a comprehensive echocardiogram. Definitions, devices, and limitations are described under point-of-care cardiac ultrasound.
Digital stethoscopes with artificial intelligence. Electronic stethoscopes amplify and filter sound, record it, and transmit it for remote review; some also record a single-lead electrocardiogram. In a validation study of a deep-learning algorithm applied to recordings from a commercial digital stethoscope in 962 patients, murmur detection had a sensitivity of 76.3% and a specificity of 91.4%, rising to a sensitivity of 90.0% when grade 1 murmurs were excluded. At the appropriate auscultation site, the algorithm detected moderate-to-severe or greater aortic stenosis with a sensitivity of 93.2% and a specificity of 86.0%, and moderate-to-severe or greater mitral regurgitation with a sensitivity of 66.2% and a specificity of 94.6% (Chorba 2021). These tools function as screening aids that lead to echocardiography; their effect on outcomes has not been established in randomized trials.
Phonocardiography. Recording heart sounds with a simultaneous electrocardiogram, carotid pulse, or jugular pulse tracing established the timing relations of the heart sounds and murmurs, including the intervals between A2 and the opening snap and between S1 and ejection clicks. Phonocardiography has left routine clinical practice. Recorded sounds and digital stethoscope recordings are now the standard means of teaching and assessing auscultation, and repeated listening to annotated recordings improves recognition.
Murmurs in pregnancy, athletes, endocarditis, and after myocardial infarction
Pregnancy. Plasma volume and cardiac output rise, so a soft systolic flow murmur, a physiologic S3, a venous hum, and a mammary souffle are common, while stenotic murmurs become louder for the same valve area. Diastolic murmurs, a systolic murmur of grade 3/6 or louder, and an S4 lead to evaluation (normal pregnancy findings).
Athletes. Training increases stroke volume and slows the heart, and soft flow murmurs and a physiologic S3 are common. The AHA 14-element preparticipation examination includes auscultation supine and standing, or with Valsalva, to detect dynamic outflow obstruction, and palpation of the femoral pulses to exclude coarctation (Maron 2015). A murmur that becomes louder on standing, a harsh ejection murmur with a click, and any diastolic murmur lead to echocardiography (athlete screening).
Infective endocarditis. A new or changed regurgitant murmur is a central finding. Many patients have preexisting murmurs, and a murmur may be absent early, in right-sided disease, and in device infection (endocarditis presentation). A new diastolic murmur of aortic regurgitation with heart failure in a febrile patient indicates valve destruction.
After myocardial infarction. A new murmur with hemodynamic deterioration in the first week indicates a mechanical complication until echocardiography excludes it. A loud holosystolic murmur with a thrill favors ventricular septal rupture; a soft or absent murmur with abrupt pulmonary edema favors papillary muscle rupture; and a late-peaking ejection murmur with a hyperdynamic base indicates dynamic outflow obstruction (mechanical complications). A pericardial friction rub in the first days reflects infarct-associated pericarditis.
Precordial inspection and palpation
Inspection identifies chest wall deformity, prior sternotomy or thoracotomy, device pockets, and visible pulsations. Palpation uses the fingertips for the apical impulse and the heel of the hand for parasternal lifts and thrills.
The apical impulse is normally a brief outward tap in early systole, located in the fifth intercostal space at or inside the midclavicular line and occupying an area no larger than one intercostal space. It is examined supine and, if not felt, in the left lateral decubitus position, which displaces it leftward. Its location, size, duration, and contour distinguish pressure from volume loading.
| Finding | Mechanism | Associated conditions |
|---|---|---|
| Sustained, nondisplaced apical heave | Concentric hypertrophy; prolonged ejection against pressure load | Aortic stenosis; hypertension; hypertrophic cardiomyopathy |
| Hyperdynamic, displaced, diffuse apex | Volume load with eccentric dilation | Aortic or mitral regurgitation; large left-to-right shunt |
| Diffuse, displaced, weak apex | Dilated, poorly contracting ventricle | Dilated cardiomyopathy; ischemic cardiomyopathy |
| Double or triple apical impulse | Palpable atrial contraction (S4) with or without a midsystolic dip | Hypertrophic cardiomyopathy |
| Tapping apex | Palpable loud S1 | Mitral stenosis |
| Ectopic paradoxical impulse above the apex | Dyskinetic segment | Left ventricular aneurysm after anterior infarction |
| Left parasternal lift | Right ventricular pressure or volume load; also systolic left atrial expansion in severe mitral regurgitation | Pulmonary hypertension; atrial septal defect; pulmonic stenosis; severe mitral regurgitation |
| Palpable P2 at the left second intercostal space | Forceful pulmonic closure | Pulmonary hypertension |
| Thrill | Palpable murmur of grade 4/6 or louder | Aortic or pulmonic stenosis at the base; ventricular septal defect at the left lower sternal border; severe mitral regurgitation at the apex |
Findings on precordial palpation.
Jugular venous pressure: technique and measurement
The internal jugular vein connects to the right atrium through the superior vena cava without valves, so its pulsation reflects right atrial pressure and waveform. The right internal jugular is preferred because it runs a straight course to the atrium. The external jugular vein can be used for pressure when the internal jugular is not visible; it is less reliable because of its valves and angulated course.
Technique. The patient reclines with the head supported and turned slightly to the left, in tangential light. The internal jugular pulsation is sought between the two heads of the sternocleidomastoid muscle and behind it, at the height of the venous column. The trunk is elevated to whatever angle brings the top of the column into view: about 30° to 45° for most patients, upright for a markedly raised pressure (which may otherwise be hidden at the angle of the jaw), and flat for a low pressure.
The vertical height of the column above the sternal angle is measured by extending a horizontal straightedge from the top of the column to a vertical ruler held at the sternal angle. With the conventional assumption that the right atrium lies about 5 cm below the sternal angle, adding 5 cm to the measured height gives the estimated right atrial pressure in centimeters of water. A height of more than 3 cm above the sternal angle, corresponding to an estimated right atrial pressure above 8 cm of water, is conventionally regarded as elevated. Dividing by 1.36 converts centimeters of water to millimeters of mercury.
Limits of the 5-cm convention. In 160 patients undergoing chest CT, the median distance from the sternal angle to the mid-right atrium was 5.4 cm supine, and calculated distances were 8 cm at 30°, 9.7 cm at 45°, and 9.8 cm at 60° elevation, with wide variation between patients (Seth 2002). The 5-cm correction therefore underestimates right atrial pressure in the semi-upright positions used for examination. For serial assessment, the same position and reference point are used and the measured height is recorded with the angle of elevation.
| Feature | Internal jugular venous pulse | Carotid arterial pulse |
|---|---|---|
| Palpation | Rarely palpable; soft and undulating | Palpable, firm single outward thrust |
| Waveform | Two or three peaks per beat (a, v) with inward descents | Single brisk outward upstroke |
| Light pressure at the base of the neck | Obliterates the pulsation; the column fills from above | No effect |
| Position | Level changes with elevation of the trunk | Unchanged by position |
| Respiration | Level falls with inspiration (except in Kussmaul sign) | Unchanged |
| Abdominal pressure | Level rises transiently, or in a sustained way when filling pressure is high | Unchanged |
| Dominant motion | Inward (x and y descents) | Outward |
Distinction between the jugular venous and carotid arterial pulsations in the neck.
Point-of-care ultrasound of the internal jugular vein and the inferior vena cava locates the top of the venous column when the neck is difficult to examine. The point-of-care ultrasound page describes inferior vena cava assessment of right atrial pressure.
Jugular venous waveform: a, c, and v waves and the x and y descents
The normal jugular pulse has two visible positive waves and two descents per cycle. The a wave is produced by right atrial contraction and follows the P wave, just before S1. The c wave, rarely seen at the bedside, reflects bulging of the tricuspid valve toward the atrium at the onset of ventricular systole and transmission from the adjacent carotid artery. The x descent reflects atrial relaxation and the descent of the tricuspid annulus during ventricular ejection; it is the dominant inward motion in sinus rhythm and coincides with the carotid upstroke. The v wave reflects atrial filling against a closed tricuspid valve and peaks at the end of systole, just after S2. The y descent reflects tricuspid opening and rapid emptying of the atrium into the ventricle in early diastole. The same waves appear on the right atrial pressure tracing, described with right heart catheterization.
| Waveform abnormality | Mechanism | Causes |
|---|---|---|
| Large a wave | Atrial contraction against resistance to right atrial emptying | Tricuspid stenosis; right ventricular hypertrophy from pulmonic stenosis or pulmonary hypertension; reduced right ventricular compliance |
| Cannon a waves (intermittent) | Atrial contraction against a closed tricuspid valve | Atrioventricular dissociation: complete heart block, ventricular tachycardia, ventricular pacing with retrograde or dissociated atrial activity |
| Cannon a waves (regular) | Atrial and ventricular contraction simultaneous on all beats | Junctional rhythm; atrioventricular nodal reentrant tachycardia; VVI pacing with 1:1 retrograde conduction |
| Absent a wave | No organized atrial contraction | Atrial fibrillation |
| Large v wave (c-v wave) with loss of the x descent | Systolic regurgitation into the right atrium | Severe tricuspid regurgitation; the earlobe may move with systole and the liver pulsates |
| Steep, deep y descent (Friedreich sign); M or W contour | Unimpeded early diastolic filling followed by an abrupt halt | Constrictive pericarditis; restrictive cardiomyopathy; severe right ventricular failure; severe tricuspid regurgitation |
| Blunted or absent y descent with a preserved x descent | Pericardial pressure limits filling throughout diastole | Cardiac tamponade |
| Slow y descent | Obstruction to right ventricular inflow | Tricuspid stenosis; right atrial myxoma |
| Raised, nonpulsatile venous pressure | Obstruction of the superior vena cava | Superior vena cava syndrome; facial and arm swelling, distended chest wall veins |
Abnormalities of the jugular venous waveform.
Cannon a waves are a bedside sign of atrioventricular dissociation and help separate ventricular tachycardia from supraventricular tachycardia with aberrancy; they also produce the neck pulsations and hypotension of pacemaker syndrome. In tamponade, a blunted y descent with pulsus paradoxus contrasts with the steep y descent and Kussmaul sign of constriction. When the bedside findings overlap, the invasive respiratory pattern separates the two (constrictive pericarditis; tamponade).
Abdominojugular test and Kussmaul sign
Abdominojugular test. The patient reclines at the angle at which the top of the venous column is visible. Firm, steady pressure is applied with the palm over the midabdomen for 10 to 15 seconds while the patient breathes normally and avoids a Valsalva maneuver. In a normal person, the jugular pressure rises briefly and returns to baseline within a few seconds despite continued pressure. A positive test is a sustained rise during compression, with an abrupt fall on release. The test reflects a central blood volume that the right heart cannot accommodate.
In a standardized catheterization study, a positive test was defined as an abrupt fall of at least 3 mm Hg (4 cm of blood) on release of 10 seconds of compression. Patients with a positive test had a mean pulmonary artery wedge pressure of 19 mm Hg, compared with 10.5 mm Hg in those with a negative response. In the absence of isolated right ventricular failure, a positive test suggests a wedge pressure of 15 mm Hg or greater (Ewy 1988).
In 65 patients without heart failure, the response stabilized by 15 seconds in 62, and bedside and catheterization results agreed (kappa 0.74). A sustained rise of 1 cm or more predicted a right atrial pressure above 9 mm Hg with a sensitivity of 100% and a specificity of 85% (Sochowski 1990). The older term hepatojugular reflux reflects the original practice of compressing the liver; midabdominal compression is less painful and equally informative.
Kussmaul sign. Normally, inspiration lowers intrathoracic and right atrial pressure, and the jugular pressure falls. In Kussmaul sign the jugular pressure fails to fall or rises with inspiration, because the right heart cannot accept the inspiratory increase in venous return. It occurs in constrictive pericarditis, restrictive cardiomyopathy, right ventricular infarction, severe right ventricular failure, severe tricuspid regurgitation, tricuspid stenosis, and massive pulmonary embolism. It therefore indicates impaired right heart filling without identifying the cause. Classic tamponade does not produce it, because pericardial pressure falls with inspiration; its presence in a patient with tamponade raises the possibility of an effusive-constrictive process (constrictive pericarditis; restrictive cardiomyopathy; right ventricular failure).
Accuracy and prognostic value of the jugular venous pressure in heart failure
The jugular venous pressure is the most useful bedside sign of congestion. In most patients with chronic heart failure with reduced ejection fraction, right and left filling pressures rise together, so an elevated jugular pressure also predicts a raised wedge pressure. The minority with a mismatch, most often with severe tricuspid regurgitation or right ventricular disease, is described on the acute decompensated heart failure page.
In 52 patients with advanced chronic heart failure evaluated for transplantation, jugular venous distension at rest or induced by the abdominojugular test had a sensitivity of 81%, a specificity of 80%, and a predictive accuracy of 81% for a wedge pressure of 18 mm Hg or higher. The probability of an elevated wedge pressure was 0.86 when either finding was present (Butman 1993). Crackles and edema were often absent despite high filling pressures in chronic heart failure (Stevenson 1989).
In a retrospective analysis of the SOLVD treatment trial, an elevated jugular venous pressure was independently associated with hospitalization for heart failure (relative risk 1.32), death or hospitalization for heart failure (1.30), and death from pump failure (1.37), after adjustment for other markers of severity (Drazner 2001). The 2022 AHA/ACC/Heart Failure Society of America (HFSA) guideline recommends assessment of vital signs and evidence of clinical congestion at all encounters to guide overall management, including adjustment of diuretics and other medications (Class 1, Level B-NR) (Heidenreich 2022).
The bedside hemodynamic profile combines congestion (wet or dry) with perfusion (warm or cold) to classify decompensated heart failure into four profiles. The profile, the proportional pulse pressure as a marker of low cardiac index, and their prognostic value are described on the acute decompensated heart failure and cardiogenic shock pages.
Arterial pulse patterns
The arterial pulse is assessed for rate, rhythm, amplitude, contour, and symmetry. Contour is judged at the carotid artery, closest to the aortic root and least distorted by peripheral reflection; the carotids are palpated one at a time, low in the neck. The radial and femoral pulses are compared for timing, and both arms are compared for amplitude and pressure.
Pulsus parvus et tardus. A small-volume pulse with a slow, delayed upstroke and a late peak reflects fixed left ventricular outflow obstruction and is a feature of severe aortic stenosis. In older patients with stiff arteries, the upstroke can feel normal despite severe stenosis (aortic stenosis examination).
Bounding (collapsing, water-hammer) pulse. A large-volume pulse with a rapid upstroke and an abrupt collapse reflects a large stroke volume ejected into an arterial tree that empties rapidly. It occurs in chronic severe aortic regurgitation and in high-output states: arteriovenous fistula, patent ductus arteriosus, thyrotoxicosis, anemia, pregnancy, fever, and sepsis.
Pulsus bisferiens. Two systolic peaks within one beat occur when a large stroke volume is ejected rapidly: in significant aortic regurgitation, alone or with aortic stenosis, and in high-output states. In obstructive hypertrophic cardiomyopathy, a brisk early upstroke, a midsystolic dip as obstruction develops, and a secondary rise produce a related bifid "spike-and-dome" pulse.
Dicrotic pulse. Two palpable peaks, one in systole and one in diastole after the dicrotic notch, occur with a markedly reduced stroke volume in a compliant arterial tree, as in dilated cardiomyopathy with low output in younger patients, and in low-resistance febrile states. The diastolic timing of the second peak distinguishes it from a bisferiens pulse.
Pulsus alternans. Strong and weak beats alternate with a regular rhythm. It indicates severe left ventricular systolic dysfunction and carries a poor prognosis. It is detected more sensitively with a sphygmomanometer: during slow deflation, Korotkoff sounds are first heard on alternate beats only, and the rate of audible sounds doubles at a lower pressure. Pulsus bigeminus also alternates strong and weak beats, but the rhythm is irregular, because the weak beats are premature contractions with reduced filling. Total electrical alternans on the electrocardiogram is a separate sign, associated with a large pericardial effusion.
Pulsus paradoxus. An inspiratory fall in systolic pressure of more than 10 mm Hg during quiet breathing reflects exaggerated ventricular interdependence. It is characteristic of cardiac tamponade and also occurs with severe asthma or obstructive lung disease, massive pulmonary embolism, right ventricular infarction, and tension pneumothorax. Its measurement with a sphygmomanometer and the conditions that mask it are on the tamponade page, with a Doppler and pulsus paradoxus calculator.
Radiofemoral delay and the arm-leg gradient. In coarctation of the aorta, the femoral pulse is weak and delayed relative to the radial pulse, and the arm pressure exceeds the leg pressure. Leg pressures are normally equal to or higher than arm pressures. An arm-leg gradient of more than 20 mm Hg is a criterion for significant coarctation in the adult congenital guideline cited on the hypertension page. Interscapular collateral murmurs and rib notching on the chest radiograph are associated findings.
Pulse asymmetry. A difference in amplitude or systolic pressure between the arms indicates subclavian or brachiocephalic stenosis, and, in a patient with acute chest pain, raises the possibility of aortic dissection.
| Pulse pattern | Contour | Mechanism | Causes |
|---|---|---|---|
| Parvus et tardus | Small, slow-rising, late peak | Fixed outflow obstruction | Severe aortic stenosis |
| Bounding (water-hammer) | Large, rapid rise, abrupt collapse | Large stroke volume with rapid runoff | Chronic aortic regurgitation; high-output states |
| Bisferiens | Two systolic peaks | Rapid ejection of a large stroke volume | Aortic regurgitation with or without stenosis |
| Spike and dome | Brisk spike, midsystolic dip, secondary rise | Dynamic midsystolic outflow obstruction | Obstructive hypertrophic cardiomyopathy |
| Dicrotic | Systolic peak and a second diastolic peak | Low stroke volume with a compliant arterial tree | Dilated cardiomyopathy with low output; low-resistance febrile states |
| Alternans | Alternating strong and weak beats, regular rhythm | Alternating contractile strength of a failing ventricle | Severe left ventricular dysfunction |
| Bigeminus | Alternating strong and weak beats, irregular rhythm | Premature beats with reduced filling | Ventricular or atrial bigeminy |
| Paradoxus | Inspiratory fall in systolic pressure >10 mm Hg | Exaggerated ventricular interdependence | Tamponade; severe asthma; massive pulmonary embolism |
| Radiofemoral delay | Femoral pulse weak and later than radial | Obstruction of the descending aorta | Coarctation of the aorta |
Arterial pulse patterns and their causes.
Pulse pressure. A wide pulse pressure reflects a large stroke volume, rapid diastolic runoff, or a stiff aorta: aortic regurgitation, high-output states, and the aortic stiffening of age. A narrow pulse pressure reflects a small stroke volume: severe aortic stenosis, tamponade, and low-output heart failure. In 50 patients with chronic heart failure, a proportional pulse pressure, defined as (systolic − diastolic) ÷ systolic pressure, below 25% had a sensitivity of 91% and a specificity of 83% for a cardiac index below 2.2 L/min/m² (Stevenson 1989).
Orthostatic vital signs
Blood pressure and heart rate are measured supine and again at 1 and 3 minutes after standing. Classic orthostatic hypotension is a sustained fall in systolic pressure of 20 mm Hg or more or in diastolic pressure of 10 mm Hg or more within 3 minutes of standing or head-up tilt (Freeman 2011). In patients with supine hypertension, a systolic fall of 30 mm Hg is the preferred threshold. A small heart-rate rise with a large pressure fall suggests neurogenic orthostatic hypotension. A sustained heart-rate rise of 30 beats/min or more within 10 minutes of standing, with chronic orthostatic symptoms and without orthostatic hypotension, defines the postural orthostatic tachycardia syndrome in adults. These definitions and the active stand test are described under orthostatic hypotension and autonomic disorders.
Sources of error in auscultation and the bedside examination
- Equating loudness with severity. Severe low-flow aortic stenosis, acute severe mitral or aortic regurgitation, a large ventricular septal defect, and torrential tricuspid regurgitation can produce soft or absent murmurs; a small restrictive ventricular septal defect is loud.
- Mistaking the Gallavardin murmur for mitral regurgitation. An apical musical systolic murmur in an older patient with a soft A2 and a slow carotid upstroke is transmitted aortic stenosis until echocardiography shows otherwise.
- Relying on the carotid upstroke in older adults. Stiff arteries can preserve a brisk upstroke despite severe aortic stenosis.
- Mistaking an S4 followed by S1, or S1 followed by an ejection click, for a split S1. Pitch, response to bell pressure, and site separate them.
- Mistaking an opening snap for a split S2. The snap is heard best toward the apex, does not vary with respiration in the way P2 does, and is followed by a rumble.
- Missing a diastolic murmur. Aortic regurgitation needs the sitting, forward-leaning, end-expiratory position, and mitral stenosis needs the bell at the apex in the left lateral decubitus position.
- Assuming inspiration augments all right-sided events. The pulmonic ejection click softens with inspiration, and torrential tricuspid regurgitation may not change.
- Performing the Valsalva maneuver inadequately. Without a sustained strain and a fall in pulse pressure, a negative response does not exclude dynamic obstruction; the squat-to-stand transition is the more sensitive maneuver.
- Confusing the carotid and jugular pulsations. The jugular pulse is rarely palpable, is obliterated by light pressure, changes with position and respiration, and has a dominant inward motion.
- Examining a high venous pressure in the semi-recumbent position. A column at the angle of the jaw is invisible unless the patient sits upright, and a low pressure is invisible unless the patient lies flat.
- Treating the 5-cm correction as fixed. The sternal angle lies farther above the right atrium at 45° than supine, so a reading without the angle of elevation cannot be compared over time.
- Mistaking pulsus bigeminus for alternans. Alternans has a regular rhythm; bigeminus has an irregular one.
- Accepting a normal focused ultrasound as excluding valve disease. Grayscale imaging does not grade stenosis or regurgitation; a murmur with an abnormal valve leads to a comprehensive echocardiogram.
- Labeling a murmur innocent in the presence of other abnormalities. An ejection click, an abnormal S2, a thrill, a diastolic component, symptoms, or an abnormal electrocardiogram removes the murmur from the innocent category.
References
- Otto CM, Nishimura RA, Bonow RO, et al. 2020 ACC/AHA guideline for the management of patients with valvular heart disease: a report of the American College of Cardiology/American Heart Association Joint Committee on Clinical Practice Guidelines. Circulation. 2021;143:e72–e227. doi:10.1161/CIR.0000000000000923
- Doherty JU, Kort S, Mehran R, et al. ACC/AATS/AHA/ASE/ASNC/HRS/SCAI/SCCT/SCMR/STS 2017 appropriate use criteria for multimodality imaging in valvular heart disease. J Am Coll Cardiol. 2017;70:1647–1672. doi:10.1016/j.jacc.2017.07.732
- Heidenreich PA, Bozkurt B, Aguilar D, et al. 2022 AHA/ACC/HFSA guideline for the management of heart failure. Circulation. 2022;145:e895–e1032. doi:10.1161/CIR.0000000000001063
- Ommen SR, Ho CY, Asif IM, et al. 2024 AHA/ACC/AMSSM/HRS/PACES/SCMR guideline for the management of hypertrophic cardiomyopathy. Circulation. 2024;149:e1239–e1311. doi:10.1161/CIR.0000000000001250
- Spencer KT, Kimura BJ, Korcarz CE, et al. Focused cardiac ultrasound: recommendations from the American Society of Echocardiography. J Am Soc Echocardiogr. 2013;26:567–581. doi:10.1016/j.echo.2013.04.001
- Kirkpatrick JN, Panebianco N, Díaz-Gómez JL, et al. Recommendations for cardiac point-of-care ultrasound nomenclature. J Am Soc Echocardiogr. 2024;37:809–819. doi:10.1016/j.echo.2024.05.001
- Maron BJ, Levine BD, Washington RL, et al. Eligibility and disqualification recommendations for competitive athletes with cardiovascular abnormalities: Task Force 2: preparticipation screening for cardiovascular disease in competitive athletes: a scientific statement from the American Heart Association and American College of Cardiology. Circulation. 2015;132:e267–e272. doi:10.1161/CIR.0000000000000238
- Freeman R, Wieling W, Axelrod FB, et al. Consensus statement on the definition of orthostatic hypotension, neurally mediated syncope and the postural tachycardia syndrome. Clin Auton Res. 2011;21:69–72. doi:10.1007/s10286-011-0119-5
- Lembo NJ, Dell'Italia LJ, Crawford MH, O'Rourke RA. Bedside diagnosis of systolic murmurs. N Engl J Med. 1988;318:1572–1578. doi:10.1056/NEJM198806163182404
- Etchells E, Bell C, Robb K. Does this patient have an abnormal systolic murmur? JAMA. 1997;277:564–571. doi:10.1001/jama.1997.03540310062036
- Freeman AR, Levine SA. The clinical significance of the systolic murmur: a study of 1000 consecutive “non-cardiac” cases. Ann Intern Med. 1933;6:1371–1385. doi:10.7326/0003-4819-6-11-1371
- Mangione S, Nieman LZ. Cardiac auscultatory skills of internal medicine and family practice trainees: a comparison of diagnostic proficiency. JAMA. 1997;278:717–722. doi:10.1001/jama.1997.03550090041030
- Gardezi SKM, Myerson SG, Chambers J, et al. Cardiac auscultation poorly predicts the presence of valvular heart disease in asymptomatic primary care patients. Heart. 2018;104:1832–1835. doi:10.1136/heartjnl-2018-313082
- Kobal SL, Trento L, Baharami S, et al. Comparison of effectiveness of hand-carried ultrasound to bedside cardiovascular physical examination. Am J Cardiol. 2005;96:1002–1006. doi:10.1016/j.amjcard.2005.05.060
- Chorba JS, Shapiro AM, Le L, et al. Deep learning algorithm for automated cardiac murmur detection via a digital stethoscope platform. J Am Heart Assoc. 2021;10:e019905. doi:10.1161/JAHA.120.019905
- Marcus GM, Gerber IL, McKeown BH, et al. Association between phonocardiographic third and fourth heart sounds and objective measures of left ventricular function. JAMA. 2005;293:2238–2244. doi:10.1001/jama.293.18.2238
- Drazner MH, Rame JE, Stevenson LW, Dries DL. Prognostic importance of elevated jugular venous pressure and a third heart sound in patients with heart failure. N Engl J Med. 2001;345:574–581. doi:10.1056/NEJMoa010641
- Butman SM, Ewy GA, Standen JR, Kern KB, Hahn E. Bedside cardiovascular examination in patients with severe chronic heart failure: importance of rest or inducible jugular venous distension. J Am Coll Cardiol. 1993;22:968–974. doi:10.1016/0735-1097(93)90405-P
- Ewy GA. The abdominojugular test: technique and hemodynamic correlates. Ann Intern Med. 1988;109:456–460. doi:10.7326/0003-4819-109-6-456
- Sochowski RA, Dubbin JD, Naqvi SZ. Clinical and hemodynamic assessment of the hepatojugular reflux. Am J Cardiol. 1990;66:1002–1006. doi:10.1016/0002-9149(90)90940-3
- Seth R, Magner P, Matzinger F, van Walraven C. How far is the sternal angle from the mid-right atrium? J Gen Intern Med. 2002;17:852–856. doi:10.1046/j.1525-1497.2002.20101.x
- Stevenson LW, Perloff JK. The limited reliability of physical signs for estimating hemodynamics in chronic heart failure. JAMA. 1989;261:884–888. doi:10.1001/jama.1989.03420060100040
- Roy CL, Minor MA, Brookhart MA, Choudhry NK. Does this patient with a pericardial effusion have cardiac tamponade? JAMA. 2007;297:1810–1818. doi:10.1001/jama.297.16.1810
- Pinede L, Duhaut P, Loire R. Clinical presentation of left atrial cardiac myxoma: a series of 112 consecutive cases. Medicine (Baltimore). 2001;80:159–172. doi:10.1097/00005792-200105000-00002
- Nishimura RA, Otto CM, Bonow RO, et al. 2014 AHA/ACC guideline for the management of patients with valvular heart disease. J Am Coll Cardiol. 2014;63:e57–e185. doi:10.1016/j.jacc.2014.02.536