CardioBoardExam.com

Library › Imaging › Doppler hemodynamics

Doppler hemodynamics: pressures, gradients, stroke volume and shunts

How Doppler echocardiography measures velocity and converts it into pressure gradients, intracardiac and pulmonary pressures, stroke volume, cardiac output, shunt ratios, and resistance, with the assumptions and errors of the individual methods.

Doppler echocardiography measures blood velocity, and the simplified Bernoulli equation converts a peak velocity into a pressure difference of 4v². Adding right atrial pressure to the tricuspid regurgitant gradient gives right ventricular systolic pressure, and subtracting a jet gradient from cuff pressure gives left atrial or left ventricular diastolic pressure. The product of flow area and velocity-time integral gives stroke volume, and stroke volumes at two sites give the shunt ratio, the regurgitant volume, and the valve area. All derived values inherit the errors of their inputs, and the squared terms double them.

The Doppler equation and angle dependence

Ultrasound reflected from moving red cells returns at a frequency different from the transmitted frequency. Cells moving toward the transducer return a higher frequency and cells moving away a lower one, and the difference is the Doppler shift. By convention, flow toward the transducer is displayed above the baseline and flow away from it below. The position of a signal relative to the baseline shows only direction relative to the transducer. It does not identify the phase of the cardiac cycle, and from a different window the same flow appears on the opposite side.

The Doppler equation relates the shift (Δf) to blood velocity (v): Δf = 2 × f₀ × v × cos θ ÷ c, where f₀ is the transmitted frequency, θ is the angle between the beam and the direction of flow, and c is the speed of sound in soft tissue, 1,540 m/s. The factor of 2 reflects the round trip of the signal. Solved for velocity, v = c × Δf ÷ (2 × f₀ × cos θ). The instrument measures Δf, uses the known f₀ and c, and assumes an angle of 0°. A 2.5-MHz beam meeting blood that moves along the beam toward the transducer at 1.0 m/s returns a shift of about 3.2 kHz. This is in the audible range, which is why Doppler signals can be played as sound. Doubling the transmitted frequency doubles the shift for the same velocity, so a lower transmitted frequency is used for high-velocity flow.

The cosine term makes all Doppler velocities angle dependent, and misalignment can only lower the measured velocity. The recorded velocity equals the true velocity × cos θ. The underestimate is about 6% at 20°, 13% at 30°, and 50% at 60°, and flow perpendicular to the beam produces no shift. Because the gradient depends on the square of velocity, a 13% velocity error becomes about a 25% gradient error. Angle correction is not applied to intracardiac jets, because the three-dimensional direction of a jet cannot be judged from a two-dimensional image. The 2002 American Society of Echocardiography (ASE) Doppler quantification recommendations and the 2019 ASE comprehensive transthoracic examination guideline therefore recommend recording stenotic and regurgitant jets from all windows that might align with them. The highest velocity from a dense, well-defined envelope is reported. A small nonimaging continuous-wave transducer (pencil probe) fits between ribs and in the suprasternal notch, is more sensitive than an imaging transducer, and often records a higher, better-aligned velocity.

Pulsed-wave, high pulse repetition frequency, continuous-wave, and color Doppler

Pulsed-wave Doppler transmits a short burst and opens a receive gate only at the time corresponding to a chosen depth. The sample volume gives range resolution, the ability to measure velocity at a known site. Pulsed-wave Doppler measures left ventricular outflow tract (LVOT) velocity, mitral and tricuspid inflow, pulmonary venous and hepatic venous flow, and tissue velocities. Its limit is aliasing. A sampled signal is reconstructed unambiguously only if it is sampled more than twice per cycle, so the highest measurable shift, the Nyquist limit, is half the pulse repetition frequency (PRF). A pulse must wait for the echo from the sample depth, so the maximum PRF falls with depth, approximately 77,000 ÷ depth in centimeters (Hz). In soft tissue, the highest velocity measurable without aliasing is about 29.6 ÷ [f₀ (MHz) × depth (cm)] m/s; at 2.5 MHz and 16 cm it is about 0.74 m/s. Above the limit, the spectral peak is cut off and wraps to the opposite side of the baseline.

High pulse repetition frequency Doppler sends the next pulse before the echo from the intended depth has returned. With two pulses in flight the Nyquist limit doubles, but echoes from the intended depth and from half that depth arrive together, so the velocity may arise at either gate. It is used for moderately high velocities when the extra gates can be placed where no competing flow exists, for example to localize the level of a subaortic gradient.

Continuous-wave Doppler uses separate transmitting and receiving elements that operate continuously, so very high velocities are recorded without aliasing. All moving scatterers along the beam contribute, and range resolution is lost: the site of the peak velocity is inferred from anatomy, timing, and envelope shape. Continuous-wave Doppler is the modality for stenotic, regurgitant, and shunt jets. When dynamic outflow tract obstruction and aortic stenosis coexist, a single continuous-wave recording through both levels cannot show which produced the peak; pulsed-wave or high-PRF sampling along the path resolves it.

Color Doppler is a multigate pulsed-wave technique that estimates mean velocity in many sample volumes and encodes it in color. It displays the location and direction of flow, aliases at a low Nyquist limit, and is the basis of the proximal isovelocity surface area (PISA) method and vena contracta measurements. The ASE recommends the smallest color sector and depth that include the structure, a color scale set to the maximum allowed for the depth when high-velocity flow is analyzed, and color gain just below the threshold for noise.

ModalitySamplingRange resolutionAliasingPrincipal uses
Pulsed-waveOne gate at a chosen depth, sampled at the PRFYesAbove the Nyquist limit, which falls with depth and with higher transmitted frequencyLVOT and RVOT velocity and VTI; mitral, tricuspid, pulmonary venous, and hepatic venous flow; tissue Doppler
High PRFTwo or more gates at a multiple of the conventional PRFAmbiguous among the gatesAt a proportionally higher limitModerately high velocity at a known site, such as the level of a subaortic gradient
Continuous-waveContinuous transmission and receptionNoneNot in clinical practiceStenotic, regurgitant, and shunt jets; dynamic obstruction; coarctation
Color flowMany pulsed gates with mean-velocity estimatesYes, spatial mapAt a low Nyquist limit, set by depth and color box sizeJet origin and direction, flow convergence (PISA), vena contracta, shunt detection
Tissue DopplerPulsed-wave with low gain, low scale, minimal wall filterYesRarely, at low velocitiesMitral and tricuspid annular e′, a′, s′; annular velocities in constriction

Spectral and color Doppler modalities. PRF, pulse repetition frequency; VTI, velocity-time integral; LVOT and RVOT, left and right ventricular outflow tract.

Aliasing in pulsed-wave Doppler is managed by changes that raise the sampling capacity. A baseline shift reallocates the displayed range toward the dominant direction and rescues a signal only when the peak lies within the total span. A velocity beyond the span requires a shallower sample or window, a lower transmitted frequency, high-PRF Doppler, or continuous-wave Doppler.

The spectral envelope: modal velocity, peak velocity, and velocity-time integral

Red cells within a sample move at different velocities, and a fast Fourier transform decomposes the returning signal into its component frequencies at intervals of a few milliseconds. A single column of the spectral display represents one analysis. Brightness reflects the number of cells moving at that velocity; the brightest band is the modal velocity. Laminar flow produces a narrow envelope with a clear spectral window beneath it, and disturbed flow beyond a stenosis or regurgitant orifice fills the window. Technical broadening arises from a large sample volume, a sample in the zone of flow acceleration, excessive gain, and the transit-time effect, which adds fine linear signals above the dense envelope at high velocity.

By ASE convention, the outer edge of the dense (modal) portion of the spectrum is traced, and the faint dispersion near peak velocity is ignored. The velocity-time integral (VTI) is the area under the traced envelope over one flow period. Because velocity multiplied by time is distance, the VTI, in centimeters, is the distance a column of blood travels during one ejection, sometimes called stroke distance.

The controls of the spectral display change the measurement independently of physiology. Excessive gain adds noise above the true peak and overestimates velocity; insufficient gain erases the edges and the onset and end of flow. A high wall filter removes low-velocity signals and is used for high-velocity jets, whereas pulmonary venous flow, the onset of mitral inflow, and tissue Doppler require a low filter. A fast sweep speed resolves time intervals and slopes (pressure half-time, acceleration time, dP/dt), and a slow sweep displays respiratory variation and the beats averaged in atrial fibrillation.

FlowModality and windowTypical adult valueValue that indicates disease
Aortic valve peak velocityCW; apical, right parasternal, suprasternal<2.0 m/s2.0–2.9 m/s mild, 3.0–3.9 m/s moderate, ≥4.0 m/s severe stenosis (with normal flow)
LVOT VTIPW; apical five-chamber or three-chamberAbout 17–23 cm at a normal heart rate<10 cm in acute decompensated heart failure and <15 cm in acute pulmonary embolism are associated with an adverse prognosis
Tricuspid regurgitant peak velocityCW; apical, RV inflow, parasternal short-axis, subcostal<2.8 m/s2.8–3.1 m/s mild, 3.2–3.5 m/s moderate, ≥3.6 m/s severe increase (ASE 2025)
RVOT VTIPW; parasternal short-axis, just proximal to the pulmonic valve>18 cmLow values indicate reduced right ventricular stroke volume
RVOT acceleration timePW; same site>105 ms80–105 ms mild, 60 to <80 ms moderate, <60 ms severe abnormality (ASE 2025)
Pulmonary regurgitant velocityCW; parasternal short-axisLow early and end-diastolic velocitiesEarly diastolic >2.2 m/s (ESC/ERS pulmonary artery sign); end-diastolic ≥2.0 m/s supports raised left atrial pressure (ASE 2025)
Mitral E/e′ (average)PW inflow and tissue Doppler<14≥14 average (septal ≥15, lateral ≥13) is a primary marker of raised left atrial pressure
Pulmonary venous flowPW; right upper pulmonary vein from apical four-chamberSystolic-dominant in adults (S ≥ D)S/D ≤0.67 supports raised left atrial pressure; systolic reversal supports severe MR
Mitral stenosis pressure half-timeCW across the mitral valve20–60 ms in normal subjects≥150 ms with valve area ≤1.5 cm² in severe stenosis

Reference Doppler velocities and time intervals in adults. Aortic grading from the 2020 American College of Cardiology/American Heart Association (ACC/AHA) valve guideline; right heart grades from the 2025 ASE right heart guideline; diastolic values from the 2025 ASE diastolic guideline; LVOT VTI from point-of-care data; normal pressure half-time from the original Doppler series. CW, continuous-wave; PW, pulsed-wave; MR, mitral regurgitation; RV, right ventricular; ESC/ERS, European Society of Cardiology/European Respiratory Society.

Chamber dimensions, volumes, and the full set of normal echocardiographic values are covered on the transthoracic echocardiography normal values page.

The Bernoulli equation: simplified and expanded forms

As blood accelerates into a narrowing, pressure energy converts into kinetic energy. The complete Bernoulli equation has three terms: convective acceleration, flow acceleration (inertia), and viscous friction. At the peak of a jet through a restrictive orifice, flow acceleration is zero and viscous losses are small, so only the convective term remains. With blood density and the conversion to millimeters of mercury combined into a constant, the expanded form is ΔP = 4(v₂² − v₁²), where v₂ is the jet velocity and v₁ the velocity proximal to the narrowing, both in m/s. When v₁ is small relative to v₂, the simplified form ΔP = 4v² follows.

The 2002 ASE recommendations state that the simplified equation is accurate across a restrictive orifice under most physiologic conditions. They list three exceptions: a proximal velocity above 1.5 m/s, two stenoses in series close together (for example, subpulmonic and valvular pulmonic stenosis), and a long, tunnel-like narrowing in which viscous losses are no longer negligible. The proximal term is retained in four common settings: septal hypertrophy below a stenotic aortic valve, high-output states such as anemia, coexisting aortic regurgitation that raises outflow velocity, and coarctation with a high arch velocity proximal to the narrowing.

In a patient with aortic stenosis and a hypertrophied basal septum, an outflow velocity of 2.0 m/s and an aortic velocity of 4.5 m/s give a simplified gradient of 81 mm Hg and an expanded gradient of 4 × (20.25 − 4.00) = 65 mm Hg. The simplified form overstates the valve gradient by the 16 mm Hg of kinetic energy already present below the valve. Subtracting the velocities before squaring, 4 × (4.5 − 2.0)², gives 25 mm Hg and is an arithmetic error; the velocities are squared first.

The Bernoulli equation describes a pressure difference across an orifice. It does not measure flow volume. A small, restrictive ventricular septal defect has a fast jet because left and right ventricular pressures differ widely, and its volume is small. A large, nonrestrictive defect has a slow jet because the pressures converge, and its volume can be large. A high velocity indicates a large pressure difference, and volume requires an area and a VTI.

Peak instantaneous, mean, and peak-to-peak gradients

The peak instantaneous gradient is 4v² at the highest point of the continuous-wave envelope. The mean gradient is the average of all instantaneous gradients over the flow period, computed by the instrument from the traced envelope. The mean gradient is not 4 × (mean velocity)². For a velocity that rises and falls linearly, the mean of the squared velocities is one-third of the peak squared, and the square of the mean velocity is one-quarter of it, so squaring the mean velocity underestimates the mean gradient by about a quarter. The 2002 ASE recommendations require heart rate and rhythm to be reported with all valve gradients, because flow and ejection time change both.

At catheterization, the peak-to-peak gradient is the difference between peak left ventricular and peak aortic pressure, which do not occur at the same instant. It is therefore smaller than the Doppler peak instantaneous gradient and has no physiologic counterpart; it persists in catheterization reports because it was historically read from pullback tracings. In a simultaneous Doppler and catheter study of 100 adults with calcific aortic stenosis, the Doppler gradient correlated with the maximum instantaneous catheter gradient (r = 0.92) and the mean catheter gradient (r = 0.93, standard error 10 mm Hg). It also correlated with the peak-to-peak gradient (r = 0.91) despite the different definitions, and nonsimultaneous measurements agreed less well (r = 0.79). Doppler and catheter mean gradients are the appropriate pair to compare.

GradientDefinitionSourceUse
Peak instantaneousLargest pressure difference at any instant, 4v²maxCW Doppler; catheter with simultaneous pressuresValve and outflow obstruction; dynamic LVOT gradient thresholds in HCM
MeanAverage of instantaneous gradients over the flow periodTraced CW envelope; planimetered catheter tracingsGrading of aortic, mitral, tricuspid, and prosthetic stenosis; Doppler–catheter comparison
Peak-to-peakPeak LV pressure minus peak aortic pressure, nonsimultaneousCatheter pullback onlyHistorical catheter reporting; lower than the Doppler peak instantaneous gradient
Net (recovered)Doppler gradient minus pressure recoveryCalculatedExplains Doppler–catheter differences in a small aorta and with bileaflet mechanical valves

Gradients reported by Doppler and by catheterization. HCM, hypertrophic cardiomyopathy; LV, left ventricular.

Pressure recovery and the energy loss index

Pressure is lowest at the vena contracta, the narrowest part of the jet, where Doppler records the peak velocity. Downstream, the jet decelerates and part of its kinetic energy reconverts to pressure. A catheter placed several centimeters beyond the valve therefore records a smaller gradient than Doppler, even when both are accurate. The pressure recovery is estimated as 4v² × 2 × (EOA ÷ AA) × (1 − EOA ÷ AA), where EOA is the effective orifice area and AA the cross-sectional area of the ascending aorta at the sinotubular junction. In 23 patients with aortic stenosis studied within 24 hours by both methods, this equation predicted Doppler–catheter differences that averaged 19 ± 16 mm Hg for peak and 12 ± 11 mm Hg for mean gradients, closely matching the observed differences. Recovery is greatest when the aorta is small relative to the orifice; it becomes clinically relevant mainly when the sinotubular junction is less than 30 mm in diameter. Recovery is also magnified across bileaflet mechanical prostheses, where a narrow central orifice produces a localized high velocity.

The energy loss coefficient, ELCo = (EOA × AA) ÷ (AA − EOA), corrects the valve area for recovery. When indexed to body surface area, an energy loss index of 0.5 cm²/m² or less indicates severe aortic stenosis in the 2017 European Association of Cardiovascular Imaging (EACVI)/ASE update. Its derivation, its prognostic data, and its place in grading are covered under pressure recovery and energy loss in aortic stenosis.

Velocity-time integral, stroke volume, and cardiac output

Blood ejected in systole forms a column whose base is the cross-sectional area (CSA) of the conduit and whose height is the VTI. Stroke volume (SV) = CSA × VTI, and with the conduit treated as a circle, CSA = π × (D ÷ 2)² = 0.785 × D². Square centimeters multiplied by centimeters give milliliters. Cardiac output (L/min) = SV (mL) × heart rate ÷ 1,000, and both are indexed to body surface area. The method assumes a circular area, a flat velocity profile, and a diameter and VTI measured at the same level, and it is most accurate where flow is laminar and the area changes little during the flow period.

The 2002 ASE recommendations list three sites in descending order of preference: the LVOT or aortic annulus, the mitral annulus, and the pulmonic annulus. The LVOT is used most widely. The diameter is measured on a zoomed parasternal long-axis view, inner edge to inner edge. The 2002 document measured it in early systole at the annulus and took the largest of several measurements, because a tomographic plane tends to miss the true diameter. The 2017 EACVI/ASE aortic stenosis update measures it in mid-systole at the annulus or at the level of the pulsed-wave sample, the convention now used. The pulsed-wave sample volume is placed in the apical five-chamber or three-chamber view about 5 mm proximal to the aortic valve. Spectral broadening in mid-systole or a recorded opening click indicates that the sample is in the zone of proximal acceleration; a crisp closing click often marks the correct position. The LVOT method is not applied when the annulus cannot be measured or when outflow obstruction is present, because the velocity no longer corresponds to the measured area. The mitral annulus is measured in the apical four-chamber view in early diastole with the sample at the annular level, and the pulmonic annulus in early systole in the parasternal short-axis view. The pulmonic annulus is the least reproducible of the three. The serial variability of the VTI is small, so the VTI alone tracks changes in stroke volume when the area is fixed, and the baseline diameter is reused on follow-up studies.

Parasternal long-axis image with a left ventricular outflow tract diameter of 20.6 mm, and an apical pulsed-wave Doppler recording of outflow tract velocity with a traced velocity-time integral of 19.02 cm at a heart rate of 92 beats per minute; annotations calculate an outflow area of 3.3 cm², a stroke volume of 63 mL, and a cardiac output of 5.8 L/min.
Doppler stroke volume and cardiac output. The outflow tract diameter (20.6 mm) gives an area of 0.785 × 2.06² = 3.3 cm²; multiplied by the pulsed-wave VTI of 19 cm, it gives a stroke volume of 63 mL and, at 92 beats/min, a cardiac output of 5.8 L/min. The on-screen labels are Spanish (TSVI, outflow tract; FC, heart rate). Credit: Blanco P, Ultrasound J 2020;12:21, Figure 2, PubMed Central, CC BY 4.0.

The outflow diameter is the dominant error. Because it is squared, a 1-mm error in a 2.0-cm outflow tract changes the calculated area and stroke volume by about 10%, and a 0.2-cm error (9% of a 2.2-cm diameter) changes them by about 17%. The pulsed-wave sample position is the second source: a sample 5 mm too close to the valve, in the zone of acceleration, can raise the VTI from 20 to 26 cm and overestimate stroke volume by 30%. Other errors are a diameter and VTI taken at different levels, a VTI recorded at an angle to flow, and a heart rate taken from beats other than those measured. The 2002 ASE recommendations estimate that flow ratios calculated from two sites carry an error of up to 20% even in experienced hands.

Doppler stroke volume measures forward flow through the sampled site. Volumetric stroke volume, end-diastolic minus end-systolic volume, measures total ejection. In the absence of a shunt, the difference between them is the mitral regurgitant volume. In aortic regurgitation the LVOT Doppler stroke volume already contains the regurgitant volume, so the LVOT VTI is high. The aortic regurgitant volume is estimated as the LVOT stroke volume minus the mitral inflow stroke volume or the RVOT stroke volume.

Stroke volume, cardiac output, and Qp/Qs calculator

The calculator applies the CSA × VTI method at the left and right ventricular outflow tracts. Indexed values require body surface area, and the pulmonary-to-systemic flow ratio (Qp/Qs) requires both outflow tracts measured on beats of similar cycle length.

Stroke volume, cardiac output, and Qp/Qs

CSA × VTI
Stroke volume—
Stroke volume index—
Cardiac output—
Cardiac index—
Qp/Qs—
—

SV = 0.785 × D² × VTI; cardiac output = SV × heart rate ÷ 1,000; Qp/Qs = (RVOT D² × RVOT VTI) ÷ (LVOT D² × LVOT VTI). The example (LVOT 2.0 cm and 22 cm; RVOT 2.8 cm and 20 cm; heart rate 70; body surface area 1.9 m²) gives a stroke volume of 69 mL, a stroke volume index of 36 mL/m², a cardiac output of 4.8 L/min, and a Qp/Qs of 1.8. An RVOT diameter of 2.6 cm instead of 2.8 cm lowers the ratio to 1.5.

Low flow, high flow, and their effect on gradients

All pressure gradients depend on flow. A stroke volume index below 35 mL/m² defines low flow in the grading of aortic stenosis (2017 EACVI/ASE update and 2020 ACC/AHA guideline). Low flow lowers the velocity and gradient across a severely narrowed valve and produces low-gradient severe stenosis, with or without a reduced ejection fraction. The reference transvalvular flow rate for a projected valve area at normal flow is 250 mL/s. Low-flow, low-gradient aortic stenosis, dobutamine stress, and CT calcium scoring are covered under discordant grading and low-flow aortic stenosis and stress echocardiography in low-flow aortic stenosis.

High flow has the opposite effect. Anemia, fever, sepsis, thyrotoxicosis, pregnancy, an arteriovenous fistula or dialysis access, and regurgitation through the same valve raise velocity and gradient across a moderately narrowed orifice while the valve area and dimensionless index stay in the moderate range. A patient with severe anemia has a peak aortic velocity of 4.1 m/s, a mean gradient of 42 mm Hg, a stroke volume index of 60 mL/m², a valve area of 1.30 cm², and a dimensionless index of 0.34. These values indicate moderate stenosis with high flow, and grading by velocity alone overestimates severity. The cause of high flow is reported, and the study is repeated after it resolves.

On the right side, high-output states and left-to-right shunts raise pulmonary artery pressure without a proportional rise in pulmonary vascular resistance. A high tricuspid velocity with a high RVOT VTI points to flow, and a high velocity with a low VTI points to resistance. Prosthetic valves show the same flow dependence; the Doppler velocity index changes little with flow because both velocities rise in proportion, which is why it separates high flow from obstruction.

FindingHigh-flow stateFixed obstruction or high resistance
Stroke volume indexHigh (often >50 mL/m²)Normal or low
Aortic valve area and dimensionless indexAbove the severe rangeSevere range (≤1.0 cm²; ≤0.25)
LVOT velocityRaised; expanded Bernoulli may be needed above 1.5 m/sNormal
Tricuspid velocity with RVOT VTIHigh velocity with high VTI; low TRV/VTI ratioHigh velocity with low VTI; TRV/VTI ratio >0.175
Prosthetic valveHigh gradient with normal DVI and normal acceleration timeHigh gradient with low DVI and prolonged acceleration time
Response to treating the causeGradient falls after anemia, fever, or thyrotoxicosis resolvesGradient unchanged

Separating high flow from obstruction. TRV, peak tricuspid regurgitant velocity; DVI, Doppler velocity index (dimensionless index).

The continuity equation and the dimensionless index

Flow through the LVOT in systole also crosses the aortic valve, so CSA(LVOT) × VTI(LVOT) = AVA × VTI(AV), and the effective aortic valve area (AVA) = CSA(LVOT) × VTI(LVOT) ÷ VTI(AV). The equation gives the area of the vena contracta, which is smaller than the anatomic orifice measured by planimetry. A peak-velocity version, CSA × V(LVOT) ÷ V(AV), gives a similar result. Aortic regurgitation does not invalidate the equation, because both terms measure the same systolic flow; mitral regurgitation does not affect it either. The method fails with a leak or shunt between the two sites, with mismatched beats, with an LVOT sample in the zone of acceleration (which overestimates the area), and with a misaligned continuous-wave beam (which underestimates the aortic VTI and overestimates the area).

The dimensionless index (velocity ratio, Doppler velocity index) is VTI(LVOT) ÷ VTI(AV), or the ratio of peak velocities. It removes the outflow diameter, the least reproducible input. A ratio of 0.25 or less indicates severe aortic stenosis. When the dimensionless index agrees with the velocity and gradient but the valve area does not, the outflow diameter is remeasured. For example, an LVOT diameter of 2.2 cm, an LVOT VTI of 22 cm, and an aortic VTI of 88 cm give an area of 0.95 cm² and an index of 0.25. Measuring the diameter as 2.0 cm lowers the area to 0.79 cm², and the index stays at 0.25.

In mitral stenosis, the continuity equation divides the LVOT stroke volume by the mitral stenotic VTI and is useful when the pressure half-time is unreliable; it is invalid with significant mitral or aortic regurgitation. Grading, the valve area calculator, and its sources of error are covered under aortic valve area by the continuity equation; the equivalent invasive formulas are covered under valve area by the Gorlin and Hakki formulas.

Pressure half-time in mitral stenosis and aortic regurgitation

The pressure half-time is the time for the peak pressure gradient to fall by half. Because pressure varies with velocity squared, it equals the time for the peak velocity to fall to 1/√2 of its peak value, a fall of about 30%. In an original Doppler series, the pressure half-time across the mitral valve was 20 to 60 ms in normal subjects, 35 to 80 ms in isolated mitral regurgitation, and 90 to 383 ms in mitral stenosis, and it changed little with exercise. The inverse relation between half-time and catheter valve area yielded the empirical formula mitral valve area (cm²) = 220 ÷ pressure half-time (ms), which the 2002 ASE recommendations endorse for clinical use. In the 2020 ACC/AHA valve guideline, severe mitral stenosis is a valve area of 1.5 cm² or less, which corresponds to a diastolic pressure half-time of 150 ms or more.

The formula assumes that the rate of gradient decline is governed by the orifice. It fails when other factors govern it. Tachycardia fuses the E and A waves and shortens diastole. Significant aortic regurgitation fills the left ventricle from a second source, raises its diastolic pressure quickly, shortens the half-time, and overestimates the area. Altered left atrial or left ventricular compliance or relaxation, a recent balloon valvotomy (when atrial pressure and compliance change abruptly and an iatrogenic septal defect may be present), and an atrial septal defect make the half-time unreliable. When the early deceleration is curvilinear (a ski-slope contour), the half-time is measured from the later, linear part of the descent extrapolated backward. The method is less well validated for prosthetic valves and for tricuspid stenosis.

In aortic regurgitation, the continuous-wave signal reflects the instantaneous diastolic pressure difference between aorta and left ventricle. A large regurgitant volume and a rising left ventricular diastolic pressure equalize the two pressures quickly and shorten the half-time. The 2017 ASE regurgitation guideline treats a half-time below 200 ms as supporting severe and above 500 ms as supporting mild aortic regurgitation. A complete continuous-wave envelope is required, and the 2002 ASE document specifies a peak regurgitant velocity of 4 m/s or more. The half-time also depends on left ventricular compliance and systemic vascular resistance: a stiff ventricle shortens it in moderate regurgitation, and chronic compensated severe regurgitation with a large compliant ventricle can lengthen it. Holodiastolic flow reversal in the proximal descending aorta, with an end-diastolic velocity above 20 cm/s, is a specific supportive sign of severe aortic regurgitation. A patent ductus arteriosus, an aortopulmonary window, a ruptured sinus of Valsalva aneurysm, or a large upper-limb dialysis fistula produces the same reversal through another runoff.

Regurgitant volume, flow convergence, and vena contracta

Doppler quantifies regurgitation by three methods built on the same physics. The volumetric method compares stroke volumes at two sites: in mitral regurgitation the mitral annular stroke volume carries forward and regurgitant flow, and the LVOT carries forward flow only, so regurgitant volume (RVol) = SV(mitral annulus) − SV(LVOT) and regurgitant fraction = RVol ÷ SV(mitral annulus). The reference valve must be competent, and a second regurgitant lesion or a shunt invalidates the comparison. The effective regurgitant orifice area (EROA) is then RVol ÷ VTI of the regurgitant jet.

The flow convergence (PISA) method applies conservation of mass proximal to the orifice. Blood accelerating toward a small orifice forms roughly hemispheric shells of rising velocity; at the color aliasing boundary the velocity is the aliasing velocity (Va). Regurgitant flow rate = 2πr² × Va, EROA = flow rate ÷ peak regurgitant velocity, and RVol = EROA × regurgitant VTI. The method assumes a hemispheric surface and a single round orifice; a crescentic orifice in secondary mitral regurgitation, a constrained surface needing angle correction, and a flow rate that varies through systole limit it. The vena contracta, the narrowest neck of the color jet at or just downstream of the orifice, is measured in a zoomed view perpendicular to the line of coaptation and is nearly independent of flow rate and driving pressure.

In the 2017 ASE regurgitation guideline, severe mitral regurgitation is supported by an EROA of 0.40 cm² or more, a regurgitant volume of 60 mL or more, a regurgitant fraction of 50% or more, and a vena contracta of 0.7 cm or more. Severe aortic regurgitation is supported by an EROA of 0.30 cm² or more, a regurgitant volume of 60 mL or more, a regurgitant fraction of 50% or more, and a vena contracta above 0.6 cm. Secondary mitral regurgitation, with its lower volumes and its proportionality to ventricular size, is graded separately. Technique, the PISA calculator, and the full grading tables are covered under PISA, EROA, and regurgitant volume and volumetric quantification.

Pressures from regurgitant and shunt jets

Any jet between two chambers reports the instantaneous pressure difference between them, so a known pressure in one chamber gives the pressure in the other: P(high) − P(low) = 4v². Right-sided estimates add right atrial pressure to the gradient. Left-sided and shunt estimates subtract the gradient from cuff systolic or diastolic pressure, which stands in for left ventricular systolic pressure or aortic diastolic pressure. These estimates depend on a reference pressure valid at the same instant, a beam aligned with the jet, and a complete envelope.

Pressure soughtJet and timingEquationReference pressure assumedInvalid or misleading when
Right ventricular systolic (RVSP)Peak tricuspid regurgitationRVSP = 4(TRV)² + RAPRight atrial pressure from the inferior vena cavaIncomplete or misaligned envelope; RAP misjudged; torrential TR with early equalization
Pulmonary artery systolic (PASP)As above, minus any RVOT or pulmonic gradientPASP = RVSP − 4(VPV)²No obstruction between RV and PAPulmonic stenosis, infundibular or subpulmonic obstruction, conduit stenosis
Pulmonary artery end-diastolic (PAEDP)End-diastolic pulmonary regurgitationPAEDP = 4(VPR,ED)² + RAPRV end-diastolic pressure ≈ RAPEarly diastolic velocity used; poor signal; restrictive RV physiology
Left atrial (LAP)Peak mitral regurgitationLAP = SBP − 4(VMR)²Cuff systolic pressure equals LV systolic pressureAortic stenosis or LVOT obstruction; small errors in a large gradient
Left ventricular end-diastolic (LVEDP)End-diastolic aortic regurgitationLVEDP = DBP − 4(VAR,ED)²Cuff diastolic pressure equals aortic end-diastolic pressureEarly diastolic velocity used; misaligned beam; inaccurate cuff diastolic pressure
RVSP from a ventricular septal defectPeak systolic left-to-right VSD jetRVSP = SBP − 4(VVSD)²Cuff systolic pressure equals LV systolic pressureAortic stenosis or LVOT obstruction; jet not aligned
PASP from a patent ductus arteriosusPeak systolic left-to-right ductal jetPASP = SBP − 4(VPDA)²Cuff systolic pressure equals aortic pressure at the ductCoarctation proximal to the duct; aortic obstruction

Pressures estimated from regurgitant and shunt jets. TRV, peak tricuspid regurgitant velocity; RAP, right atrial pressure; SBP and DBP, cuff systolic and diastolic blood pressure; V, peak or timed jet velocity in m/s; TR, tricuspid regurgitation; RV, right ventricle; PA, pulmonary artery; VSD, ventricular septal defect; PDA, patent ductus arteriosus.

A low-velocity septal or ductal jet indicates near-equal pressures on the two sides and therefore raised right ventricular or pulmonary pressure. Bidirectional or right-to-left flow through a defect indicates that pulmonary pressure or resistance has reached or exceeded systemic levels.

Right atrial pressure from the inferior vena cava and hepatic veins

Right atrial pressure is added to all right-sided gradients. The inferior vena cava is measured in the subcostal view just proximal to the hepatic veins, perpendicular to its long axis, at end-expiration, and its collapse is observed with a brief sniff. The 2025 ASE right heart guideline assigns 3 mm Hg to a cava of 2.1 cm or less that collapses by more than 50% and 15 mm Hg to a cava wider than 2.1 cm that collapses by less than 50%. The other combinations receive 8 mm Hg, refined by secondary signs such as hepatic venous flow and right atrial size. The same guideline grades right atrial pressure of 5 to less than 10 mm Hg as mildly, 10 to less than 15 mm Hg as moderately, and 15 mm Hg or more as severely elevated. A reappraisal against invasive measurement found that the traditional cutoffs misclassified many patients with intermediate values, which is the basis for the intermediate category of 8 mm Hg.

The inference assumes spontaneous breathing and a cava that reflects right atrial pressure. Positive-pressure ventilation distends the cava regardless of pressure; raised intra-abdominal pressure compresses it; a trained athlete may have a large cava with normal pressure; severe tricuspid regurgitation transmits a large v wave; and a poor subcostal window prevents measurement. In these settings the report states the uncertainty, and a dilated cava is not automatically assigned 15 mm Hg. Detailed caval and right atrial measurements are covered under right atrial size, inferior vena cava, and right atrial pressure.

Hepatic venous flow patterns

Pulsed-wave Doppler of a hepatic vein from the subcostal window, with flow roughly parallel to the beam, shows forward systolic (S) and diastolic (D) waves toward the heart and small reversals after atrial contraction (A) and at end-systole (V). Forward flow increases with inspiration in normal subjects. The 2002 ASE recommendations note that all waves change with respiration and that the pattern of change differs between pericardial and myocardial disease. Hepatic venous flow is not a stand-alone pressure measurement; it supports the estimate of right atrial pressure and the grading of tricuspid regurgitation.

PatternHepatic venous DopplerInterpretation
NormalSystolic forward flow ≥ diastolic forward flow; small A and V reversals; more forward flow with inspirationNormal right atrial pressure and compliance
Raised right atrial pressureSystolic blunting with diastolic predominance (S < D)Supports an intermediate or high estimate of RAP
Severe tricuspid regurgitationSystolic flow reversalSpecific supportive sign of severe TR
Atrial fibrillationBlunted systolic forward flow; no A reversalSystolic blunting is not specific in this rhythm
Constrictive pericarditisProminent diastolic flow reversal in expirationVentricular interdependence with dissociation of intrathoracic and intracardiac pressures
Restrictive cardiomyopathyDiastolic flow reversal larger in inspiration; systolic bluntingStiff right ventricle that cannot accept the inspiratory rise in venous return

Hepatic venous flow patterns in adults. Constriction and its echocardiographic criteria are covered under constrictive pericarditis.

Right ventricular and pulmonary artery systolic pressure from tricuspid regurgitation

When tricuspid regurgitation is present, the peak velocity of the regurgitant jet gives the peak systolic pressure difference between right ventricle and right atrium. Right ventricular systolic pressure (RVSP) = 4(TRV)² + RAP. Without pulmonic stenosis or outflow obstruction, RVSP equals pulmonary artery systolic pressure (PASP). With pulmonic stenosis, PASP is estimated by subtracting the peak pulmonic gradient from RVSP. Of 62 patients with clinical signs of raised right-sided pressure, 54 (87%) had a recordable tricuspid jet. The tricuspid gradient plus a clinical estimate of mean right atrial pressure correlated with catheter RVSP (r = 0.93, standard error 8 mm Hg). In a simultaneous Doppler and catheter study of 127 patients, the Doppler and catheter right ventricular–right atrial gradients correlated closely (r = 0.96, standard error 7 mm Hg). An analyzable jet was present in about 80% of patients with raised and 57% with normal right ventricular pressure.

The jet is recorded with continuous-wave Doppler from the apical, parasternal right ventricular inflow, parasternal short-axis, and subcostal windows, and the highest dense, complete envelope is reported. An incomplete envelope underestimates velocity, and agitated saline or an ultrasound-enhancing agent can complete a weak signal, provided only the dense edge is traced. Because the gradient is 4v², a 10% velocity error produces about a 21% gradient error. With a RAP of 8 mm Hg, an incomplete apical envelope peaking at 3.0 m/s gives an RVSP of 44 mm Hg, whereas a dense envelope from the right ventricular inflow view peaking at 3.5 m/s gives 57 mm Hg.

VariableNormalMildModerateSevere
Peak tricuspid regurgitant velocity (m/s)<2.82.8–3.13.2–3.5≥3.6
RVSP (mm Hg)<3535–4950–69≥70
RVOT acceleration time (ms)>10580–10560 to <80<60
Main pulmonary artery diameter (cm)≤2.5>2.5–3.0>3.0–3.5>3.5
Right atrial pressure (mm Hg)<55 to <1010 to <15≥15

Grading of right-sided hemodynamic measurements in the 2025 ASE right heart guideline. The grades describe the size of a measurement; they do not establish pulmonary hypertension or its type. An RVOT VTI above 18 cm is normal and is not graded.

Torrential tricuspid regurgitation is the main exception to the Bernoulli relation on the right side. When the coaptation gap is large, right ventricular and right atrial pressures equalize early in systole, and the envelope becomes dense, triangular, and early peaking. The velocity then underestimates the right ventricular pressure, and a low velocity does not exclude severe pulmonary hypertension. A failing right ventricle generates less pressure, so a falling RVSP with a falling RVOT VTI and a falling ratio of tricuspid annular plane systolic excursion to PASP (TAPSE/PASP) indicates deterioration despite the apparent improvement in RVSP. With the beam passing near the mitral valve, the mitral regurgitant jet can be recorded in error; its timing begins with isovolumic contraction and its velocity usually exceeds 5 m/s.

Pulmonary artery diastolic and mean pressures

Pulmonary regurgitation, present in most adults, reports the diastolic pressure difference between the pulmonary artery and the right ventricle. At end-diastole, just before the pulmonic valve opens, right ventricular pressure approximates right atrial pressure, so pulmonary artery end-diastolic pressure (PAEDP) = 4(VPR,ED)² + RAP. In patients studied against catheterization, the end-diastolic Doppler gradient correlated with the catheter end-diastolic gradient (r = 0.94) and with PAEDP (r = 0.92), and the peak early diastolic Doppler gradient correlated with mean pulmonary artery pressure (r = 0.92). The early diastolic peak therefore approximates the mean pressure gradient, and the end-diastolic velocity approximates the diastolic pressure. Substituting the early velocity for the end-diastolic velocity overestimates PAEDP. When the early peak is 2.8 m/s and the end-diastolic velocity 1.6 m/s with a RAP of 8 mm Hg, PAEDP is 4 × 1.6² + 8 = 18 mm Hg, and using the early velocity in error gives 39 mm Hg.

Several methods estimate mean pulmonary artery pressure (mPAP), and none is exact.

MethodFormulaBasis and limits
Systolic and diastolic pressuresmPAP ≈ ⅓ PASP + ⅔ PAEDPForm of the arterial mean-pressure formula used in the 2025 ASE right heart guideline; requires both tricuspid and pulmonic signals from comparable beats
Early diastolic pulmonary regurgitant gradientmPAP ≈ 4(VPR,early peak)², with RAP added in common practiceValidated against catheter mean pressure; requires a complete pulmonary regurgitant envelope
Regression on systolic pressuremPAP = 0.61 × PASP + 2 mm HgDerived from high-fidelity catheter pressures across a wide range (r² = 0.98); applied to Doppler PASP it carries the Doppler error
Mean tricuspid gradientmPAP ≈ mean RV–RA gradient (traced TR envelope) + RAPRequires a complete tricuspid envelope throughout systole
RVOT acceleration timeRegression equations on acceleration timeConfidence limits too wide for clinical estimation (2002 ASE); used as a supportive sign

Doppler estimates of mean pulmonary artery pressure. PR, pulmonary regurgitation; RV–RA, right ventricular to right atrial. The hemodynamic definition of pulmonary hypertension is a catheter mPAP above 20 mm Hg at rest.

The end-diastolic pulmonary regurgitant velocity also enters the assessment of left-sided filling. In the 2025 ASE diastolic guideline, an end-diastolic velocity of 2.0 m/s or more, or a PAEDP of 16 mm Hg or more, is an additional variable supporting raised left atrial pressure. It applies when the primary and supplemental variables are inconclusive and pulmonary vascular disease is not the cause.

Pulmonary acceleration time and mid-systolic notching

Pulsed-wave Doppler in the RVOT, with the sample just proximal to the pulmonic valve in the parasternal short-axis view, records forward flow. With normal pulmonary pressure, velocity peaks in mid-systole and the envelope is dome-shaped. As pulmonary vascular impedance rises, velocity peaks early. In the original series, the acceleration time was 137 ± 24 ms with a mean pulmonary pressure below 20 mm Hg and 97 ± 20 ms with pulmonary hypertension. The ratio of acceleration time to right ventricular ejection time correlated with the logarithm of mean pressure (r = −0.90). The 2025 ASE right heart guideline treats an acceleration time above 105 ms as normal and grades shorter times as mild, moderate, or severe abnormality. The acceleration time is unreliable at heart rates below 60 or above 100 beats/min and with a sample placed off axis or too close to the valve. The 2002 ASE recommendations judged regression equations based on it too imprecise to estimate pressure.

Mid-systolic notching is an early peak followed by abrupt deceleration and a smaller second peak. It reflects early return of reflected pressure waves from a stiff, high-resistance pulmonary vascular bed and is most often seen with high pulmonary vascular resistance. Notching and an acceleration time below 105 ms are pulmonary artery signs in the 2022 ESC/ERS probability scheme, and notching is an adjunct sign in the 2025 ASE screening rule.

Pulmonary vascular resistance by Doppler

Pressure rises when resistance rises or when flow rises, and resistance is pressure drop divided by flow. The ratio of the peak tricuspid regurgitant velocity (TRV, m/s) to the RVOT VTI (cm) separates the two: a high velocity with a short stroke distance points to resistance, and a high velocity with a long stroke distance points to flow. In 44 patients studied simultaneously by Doppler and right heart catheterization, the ratio correlated with invasive pulmonary vascular resistance (PVR; r = 0.93). The regression PVR (Wood units) = TRV ÷ RVOT VTI × 10 + 0.16 agreed with catheter values (mean difference 0 ± 0.41 Wood units). A ratio above 0.175 identified a PVR above 2 Wood units with a sensitivity of 77% and specificity of 81%.

The 2025 ASE right heart guideline includes the estimate as a screening aid. It becomes unreliable when resistance is very high, carries the errors of both inputs, and does not replace invasive PVR, which is (mPAP − pulmonary artery wedge pressure) ÷ cardiac output. No echocardiographic resistance value classifies pulmonary hypertension as pre-capillary, post-capillary, or combined. For a patient with unexplained dyspnea, a TRV of 3.8 m/s and an RVOT VTI of 11 cm give an estimate of 3.6 Wood units. For a patient with a large secundum atrial septal defect, a TRV of 3.5 m/s and an RVOT VTI of 28 cm give 1.4 Wood units, and the raised pressure reflects flow. Invasive resistance and its calculation are covered under systemic and pulmonary vascular resistance.

Right heart pressure and resistance calculator

The calculator estimates right atrial pressure from the inferior vena cava with the 2025 ASE rule, then right ventricular, pulmonary artery systolic, end-diastolic, and mean pressures and the Doppler resistance estimate. A peak pulmonic or RVOT velocity is entered only when obstruction is present.

Right heart pressures and PVR

ASE 2025
Right atrial pressure—
RVSP—
PASP—
PAEDP—
Mean PA pressure—
PVR estimate—
—

RAP: 3 mm Hg for a cava ≤2.1 cm collapsing >50%, 15 mm Hg for a cava >2.1 cm collapsing <50%, otherwise 8 mm Hg. RVSP = 4(TRV)² + RAP; PAEDP = 4(VPR,ED)² + RAP; mean pressure = ⅓ PASP + ⅔ PAEDP; PVR = TRV ÷ RVOT VTI × 10 + 0.16. The example (TRV 3.4 m/s, cava 2.0 cm without adequate collapse, end-diastolic pulmonary regurgitant velocity 2.0 m/s, RVOT VTI 12 cm) gives RAP 8 mm Hg, RVSP 54 mm Hg, PAEDP 24 mm Hg, mean pressure 34 mm Hg, and a PVR estimate of 3.0 Wood units.

Echocardiographic probability of pulmonary hypertension

Pulmonary hypertension is a catheter diagnosis, and echocardiography assigns a probability. The 2025 ASE right heart guideline treats a TRV of 2.9 m/s or more as suggesting pulmonary hypertension, and a TRV of 2.8 m/s as suggesting it when at least two adjunct signs are present. The 2022 ESC/ERS guideline grades probability from TRV bands (2.8 m/s or less or not measurable; 2.9 to 3.4 m/s; above 3.4 m/s) combined with signs from the ventricles, the pulmonary artery, and the inferior vena cava and right atrium. Both schemes grade from the measured velocity alone, because errors in RAP and velocity compound in the calculated pressure. The supporting signs, the probability calculator, the right heart phenotypes of pre-capillary and post-capillary disease, and the decision to catheterize are covered under echocardiographic probability of pulmonary hypertension.

Left atrial and left ventricular diastolic pressures from regurgitant jets

Left atrial pressure from mitral regurgitation. The peak mitral regurgitant velocity gives the systolic pressure difference between left ventricle and left atrium. Without aortic stenosis or outflow obstruction, peak left ventricular systolic pressure approximates cuff systolic pressure, so LAP = SBP − 4(VMR)². With a blood pressure of 124/68 mm Hg and a mitral velocity of 5.2 m/s, LAP is 124 − 108 = 16 mm Hg. The estimate gives left atrial pressure at peak systole, which includes any v wave and can exceed the mean pressure. Because the estimate subtracts one large number from another, small errors dominate: a mitral velocity of 5.0 m/s instead of 5.2 m/s raises the calculated LAP by 8 mm Hg. A calculated pressure below zero indicates that cuff pressure misrepresents left ventricular pressure or that the velocity is overestimated. In aortic stenosis or LVOT obstruction, left ventricular systolic pressure is cuff systolic pressure plus the outflow gradient, and the mitral velocity rises accordingly; a mitral velocity of 6 to 7 m/s is expected in severe obstruction.

Left ventricular end-diastolic pressure from aortic regurgitation. The end-diastolic aortic regurgitant velocity gives the pressure difference between aorta and left ventricle just before ejection. LVEDP = DBP − 4(VAR,ED)². With a diastolic pressure of 68 mm Hg and an end-diastolic velocity of 3.8 m/s, LVEDP is 68 − 58 = 10 mm Hg. A low end-diastolic velocity with a steep deceleration slope indicates near-equalization of aortic and ventricular pressures, as in acute severe aortic regurgitation. The early diastolic velocity does not represent end-diastole, and cuff diastolic pressure is the least accurate cuff value, so the estimate is supportive.

These jet-derived estimates are supportive and are not primary variables in the 2025 ASE diastolic algorithm.

Left ventricular dP/dt from the mitral regurgitant jet

The rate of rise of left ventricular pressure during isovolumic contraction, dP/dt, is an index of contractility. During isovolumic contraction, left atrial pressure changes little, so the rising limb of the continuous-wave mitral regurgitant envelope tracks the rise in ventricular pressure. The interval (Δt) during which the regurgitant velocity rises from 1 m/s to 3 m/s corresponds to a pressure rise of 4 × (3² − 1²) = 32 mm Hg, and dP/dt (mm Hg/s) = 32 ÷ Δt (s). In 50 patients in sinus rhythm with mitral regurgitation, the Doppler rate of pressure rise correlated with peak catheter dP/dt (r = 0.87). A rise time of 40 ms gives 800 mm Hg/s, and 20 ms gives 1,600 mm Hg/s; a shorter interval indicates a faster rise in pressure and stronger early contraction.

In 56 patients with chronic heart failure and a mean ejection fraction of 23%, a Doppler dP/dt below 600 mm Hg/s predicted death, urgent transplantation, or urgent ventricular assist device implantation. The rate of pressure fall, −dP/dt, is measured on the descending limb from 3 m/s to 1 m/s, and a −dP/dt below 450 mm Hg/s added prognostic information in the same cohort. The measurement requires a dense, complete, well-aligned upstroke recorded at a fast sweep speed; a faint or truncated upstroke lengthens Δt and underestimates dP/dt. The index is load dependent, varies with heart rate and preload, and is not used alone to classify systolic function. A slow rise of the mitral regurgitant velocity is one of the findings of a low-output state, together with a small LVOT VTI, gradual closure of the aortic valve during systole on M-mode, and beat-to-beat alternation of the outflow VTI in sinus rhythm.

Gradient, pressure recovery, and left heart pressure calculator

The calculator applies the simplified and expanded Bernoulli equations, estimates pressure recovery from the aortic diameter at the sinotubular junction and the effective orifice area, and derives left atrial pressure, LVEDP, and dP/dt from regurgitant jets.

Gradients and left heart pressures

4v² and 4(v₂² − v₁²)
Simplified gradient—
Expanded gradient—
Pressure recovery—
Left atrial pressure—
LVEDP—
dP/dt—
—

Simplified gradient = 4v²; expanded gradient = 4(v₂² − v₁²); pressure recovery = 4v² × 2(EOA ÷ AA)(1 − EOA ÷ AA), with AA the aortic area at the sinotubular junction; LAP = SBP − 4(VMR)²; LVEDP = DBP − 4(VAR,ED)²; dP/dt = 32 ÷ rise time. The example gives a simplified peak gradient of 81 mm Hg, an expanded gradient of 65 mm Hg, a pressure recovery of 21 mm Hg, an LAP of 16 mm Hg, an LVEDP of 10 mm Hg, and a dP/dt of 800 mm Hg/s.

Mitral inflow, tissue Doppler, and pulmonary venous flow

Mitral inflow is recorded with pulsed-wave Doppler from the apical four-chamber view. Velocities and time intervals that reflect the transmitral gradient (peak early diastolic [E] and atrial [A] velocities, E/A ratio, deceleration time) are measured with the sample at the leaflet tips; flow volumes are measured at the annulus, where the area is more stable. The isovolumic relaxation time is measured between the end of aortic ejection and the onset of mitral inflow, most reproducibly with a continuous-wave beam placed between the two flows. Tissue Doppler, with low gain, low scale, and a minimal wall filter, records the septal and lateral annular early diastolic velocity (e′), an index of relaxation that is relatively insensitive to left atrial pressure, so the ratio E/e′ rises with filling pressure.

The 2025 ASE diastolic guideline uses three primary variables: reduced e′ (septal 6 cm/s or less, lateral 7 cm/s or less, or average 6.5 cm/s or less), increased E/e′ (septal 15 or more, lateral 13 or more, or average 14 or more), and increased TRV (2.8 m/s or more) or PASP (35 mm Hg or more). When all three are normal, left atrial pressure is normal; when all three are abnormal, it is elevated. Mixed results are resolved with supplemental variables: a pulmonary venous S/D ratio of 0.67 or less, left atrial reservoir strain of 18% or less, and a left atrial volume index above 34 mL/m².

Pulmonary venous flow is recorded from the apical four-chamber view with the sample 1 to 2 cm inside the right upper pulmonary vein, a low color scale to locate it, and a low wall filter. The 2002 ASE recommendations measure the peak systolic (S), peak diastolic (D), and atrial reversal (Ar) velocities, the S/D ratio, and the Ar duration. They note two common errors: a sample at the venous orifice but still in the atrium, and a recording of low-velocity atrial wall motion. Systolic flow is dominant in adults with normal filling pressure, whereas a diastolic-dominant pattern is normal in young adults. An Ar duration exceeding the mitral A duration by 30 ms or more indicates a raised left ventricular end-diastolic pressure. Systolic flow reversal in the pulmonary veins is a specific sign of severe mitral regurgitation, and veins on both sides are sampled when an eccentric jet is directed into one of them.

The 2025 algorithm, its age-specific limits, grading, atrial fibrillation and special populations, and the diastolic function calculator are covered under the 2025 ASE algorithm for left atrial pressure and echocardiographic variables of diastolic function.

Shunt quantification: Qp/Qs by Doppler

The pulmonary-to-systemic flow ratio compares stroke volumes at two sites: Qp/Qs = (CSARVOT × VTIRVOT) ÷ (CSALVOT × VTILVOT), and the factor π/4 cancels. The sites depend on the level of the shunt. In an atrial septal defect or anomalous pulmonary venous return, the extra volume passes through the right heart, so the RVOT carries Qp and the LVOT carries Qs. In a ventricular septal defect, the shunted volume crosses the RVOT in systole and returns through the left heart, so the RVOT again carries Qp. In a patent ductus arteriosus, the shunt leaves the aorta beyond the LVOT and returns through the pulmonary veins, so the LVOT carries the increased flow (Qp) and the RVOT carries systemic venous return (Qs), and the ratio is inverted.

The ratio is only as reliable as the two diameters. The RVOT diameter is difficult to image, its anterior wall is often poorly defined, and the outflow tract contracts in systole. A shunt ratio of 2.0 calculated from an RVOT diameter of 3.0 cm falls to 1.5 when the diameter is remeasured as 2.6 cm. A large calculated shunt with little right ventricular enlargement is discordant and points to a diameter error. Regurgitation at either sampling site, an irregular rhythm, and beats of different cycle length also distort the ratio. For this reason, the 2015 ASE and Society for Cardiovascular Angiography and Interventions guideline relies on right heart size and septal motion together with the Doppler ratio. Cardiac magnetic resonance phase-contrast flow or oximetry at catheterization resolves discordant results. A Qp/Qs of 1.5 or more, with right heart enlargement, is the usual threshold for a hemodynamically significant left-to-right shunt.

Indications for closure, the invasive oximetry run, and operability in pulmonary hypertension are covered under transthoracic echocardiography and shunt quantification, Qp/Qs and shunt quantification at catheterization, and operability of left-to-right shunts.

Ventricular septal defect and patent ductus arteriosus jets

Ventricular septal defect. Continuous-wave Doppler aligned with the left-to-right systolic jet gives the pressure difference between the ventricles. Without outflow obstruction, RVSP = SBP − 4(VVSD)². A restrictive perimembranous defect with a jet of 4.5 m/s and a systolic pressure of 120 mm Hg has a gradient of 81 mm Hg and an RVSP of about 39 mm Hg. A peak velocity above about 4 m/s therefore implies a restrictive defect with right ventricular pressure well below systemic, and a low velocity implies a large defect, high right ventricular pressure, or both. The tricuspid jet provides an independent RVSP, and the two estimates are compared. A jet directed through or near the tricuspid valve can mimic tricuspid regurgitation, and such a signal is not used to estimate RVSP from the tricuspid side. Right ventricular outflow obstruction, such as a double-chambered right ventricle, raises right ventricular pressure without raising pulmonary pressure.

Patent ductus arteriosus. The ductal jet enters the pulmonary artery near the left pulmonary artery origin and is recorded from the high left parasternal or suprasternal window. With left-to-right flow, the jet is continuous, peaking in late systole. PASP = SBP − 4(VPDA,systolic)², and the diastolic velocity gives the diastolic aortopulmonary difference. A velocity that falls, becomes bidirectional, or reverses indicates pulmonary pressure approaching or exceeding systemic pressure. A coarctation proximal to the duct invalidates the use of arm cuff pressure. The left heart enlarges with a hemodynamically significant duct, and holodiastolic reversal in the descending aorta reflects the diastolic runoff.

Doppler gradients in coarctation of the aorta

The suprasternal long-axis view displays the arch, the isthmus, and the proximal descending aorta. Coarctation appears as focal narrowing at the isthmus with color aliasing. Continuous-wave Doppler shows a high systolic velocity and, with significant narrowing, persistent forward flow in diastole (a diastolic tail), because a pressure difference across the coarctation persists throughout the cardiac cycle. The same persistent diastolic forward flow, with low pulsatility, is seen in the abdominal aorta.

The arch velocity proximal to the narrowing is often 1.5 m/s or more, so the expanded Bernoulli equation is used. With an isthmic velocity of 3.5 m/s and a proximal velocity of 1.5 m/s, the corrected peak gradient is 40 mm Hg, about 9 mm Hg less than the simplified value. The Doppler gradient is also affected by collaterals, which carry flow around the narrowing and lower the gradient for a given anatomic severity, by the length of the narrowed segment, and by poor arterial compliance. Features suggesting hemodynamic significance in the 2018 AHA/ACC adult congenital guideline include a Doppler mean gradient above 20 mm Hg on transthoracic echocardiography, an upper-to-lower extremity systolic gradient above 20 mm Hg, and imaging evidence of significant narrowing with collateral flow. The guideline noted that after repair, Doppler gradients may be elevated without residual narrowing because of poor arterial compliance and pressure recovery. The diastolic tail supports significance even when collaterals limit the systolic gradient. CT or magnetic resonance angiography defines the anatomy, and the 2025 ACC/AHA adult congenital guideline governs management.

Dynamic left ventricular outflow tract obstruction and provocation

Dynamic obstruction arises when the outflow tract narrows during ejection, most often from systolic anterior motion of the mitral leaflets against a hypertrophied basal septum. Narrowing worsens as the ventricle empties, so velocity rises slowly and peaks late. The continuous-wave envelope is concave and dagger-shaped, and the aortic valve may show mid-systolic partial closure on M-mode. Fixed obstruction (valvular stenosis or a subaortic membrane) produces a rounded, more symmetric envelope that peaks earlier. Color Doppler identifies the site of acceleration, and pulsed-wave or high-PRF Doppler stepped from the apex toward the valve localizes the level at which velocity rises. Intracavitary or midventricular obstruction is localized the same way.

Two Doppler recordings from apical views: (a) pulsed-wave outflow tract signal with a traced velocity-time integral of 28 cm and aliased diastolic aortic regurgitation marked by asterisks; (b) continuous-wave signal through the outflow tract with a late-peaking envelope reaching 4.2 m/s and a peak gradient of 71 mm Hg.
Two sources of error in outflow Doppler. (a) In severe aortic regurgitation, the outflow tract carries forward and regurgitant volume, and the VTI of 28 cm overstates forward stroke volume; asterisks mark the aliased regurgitant signal. (b) In dynamic outflow obstruction, pulsed-wave Doppler aliases, and continuous-wave Doppler shows a late-peaking envelope of 4.2 m/s (peak gradient 71 mm Hg); the outflow VTI cannot be used for stroke volume in this setting. Credit: Blanco P, Ultrasound J 2020;12:21, Figure 7, PubMed Central, CC BY 4.0.

The mitral regurgitant jet is the most frequent contaminant of the outflow signal, because the apical beam passes close to the mitral valve. The mitral envelope begins with isovolumic contraction, continues through isovolumic relaxation, is symmetric and denser, and usually exceeds 5 m/s. Left ventricular systolic pressure in obstruction approximates cuff systolic pressure plus the outflow gradient, so a velocity implying a ventricular pressure far above that sum indicates that the mitral jet has been sampled.

Dynamic obstruction is load dependent. Maneuvers that reduce preload or afterload or increase contractility enlarge the gradient: Valsalva strain, standing from a squat, the beat after a premature contraction, vasodilators, and amyl nitrite where available. Squatting, isometric handgrip, passive leg raising, and volume expansion reduce it. The Valsalva maneuver has four phases; the gradient is measured during sustained strain (phase 2), when venous return falls and the ventricle shrinks, and an effective strain is confirmed by a fall in mitral E velocity and ventricular size. A fixed obstruction responds in the opposite direction, with a lower gradient during strain because flow falls. With a subaortic membrane, a rounded envelope of 4.0 m/s at rest can fall to 3.6 m/s during strain; with septal hypertrophy, a late-peaking envelope can rise from 2.4 m/s at rest to 4.0 m/s.

In hypertrophic cardiomyopathy, the 2024 AHA/ACC guideline and the 2022 ASE imaging recommendations define obstruction as a resting or provoked peak gradient of 30 mm Hg or more. A gradient of 50 mm Hg or more is the threshold at which septal reduction therapy is considered for drug-refractory symptoms. For a resting peak gradient below 50 mm Hg, transthoracic echocardiography with provocative maneuvers is recommended (Class 1); for a symptomatic patient who does not reach 50 mm Hg at rest or with maneuvers, exercise echocardiography is recommended (Class 1). Dobutamine is not used to provoke obstruction in hypertrophic cardiomyopathy, because it produces intracavitary gradients in normal hearts. Outside hypertrophic cardiomyopathy, dynamic obstruction occurs in hypovolemia, during inotrope infusion, in takotsubo syndrome with a hypercontractile base, after anterior infarction with hyperkinetic basal segments, and after mitral repair with a long posterior leaflet. In shock, dynamic obstruction is treated by stopping inotropes and restoring volume. Measurement and management in hypertrophic cardiomyopathy are covered under measuring and provoking the outflow gradient.

FeatureDynamic LVOT obstructionFixed obstruction (valvular AS, subaortic membrane)Mitral regurgitant jet
Envelope shapeLate-peaking, concave, dagger-shapedRounded, symmetric; peaks earlier with mild disease and later with severe diseaseSymmetric, rounded, dense
TimingEjection only; velocity rises through mid and late systoleEjection onlyBegins with isovolumic contraction; extends through isovolumic relaxation
Typical peak velocityVariable, often 3–5 m/sVariableUsually >5 m/s
Valsalva strain or standingGradient risesGradient falls or is unchangedVelocity changes with ventricular pressure
Squat, handgrip, volumeGradient fallsGradient unchanged or rises with flow—
Associated findingsSystolic anterior motion; mid-systolic aortic valve closure; posteriorly directed MRValve calcification or a discrete membrane; post-stenotic aortic changesMitral valve disease or ventricular dilation

Distinguishing continuous-wave signals in the apical five-chamber view. AS, aortic stenosis; LVOT, left ventricular outflow tract; MR, mitral regurgitation.

Prosthetic valve gradients, Doppler velocity index, and mismatch

All prostheses are mildly stenotic, and its normal gradient depends on type, size, and flow. The 2024 ASE prosthetic valve guideline grades prosthetic aortic stenosis with flow-dependent variables (peak velocity and mean gradient) and flow-independent variables (Doppler velocity index and effective orifice area), supported by the jet contour and acceleration time. For a surgical aortic prosthesis, a peak velocity of 4 m/s or more, a mean gradient of 35 mm Hg or more, a Doppler velocity index (LVOT VTI ÷ prosthetic VTI) below 0.25, a rounded symmetric contour, and an acceleration time above 100 ms suggest significant stenosis. A transcatheter valve is graded by change from its baseline study. A high gradient with a normal Doppler velocity index and a short acceleration time indicates high flow or patient–prosthesis mismatch, whereas a high gradient with a low index and a long acceleration time indicates obstruction by thrombus or pannus.

Patient–prosthesis mismatch is an effective orifice area that is too small for the patient's body size, expressed as the effective orifice area indexed to body surface area. Because of pressure recovery beyond their narrow central orifice, bileaflet mechanical valves can show Doppler gradients that exceed catheter gradients. Normal values, mismatch thresholds by body mass index, mitral and tricuspid prosthetic criteria, and a prosthetic Doppler calculator are covered under Doppler assessment of prosthetic aortic valves and patient–prosthesis mismatch.

Doppler in atrial fibrillation and other irregular rhythms

Stroke volume, velocity, and gradient vary from beat to beat with the preceding cycle length. The beat after a long pause has a larger stroke volume and a higher gradient, and the beat after a short cycle has a smaller one. The 2002 ASE recommendations call for averaging 5 to 10 cycles in atrial fibrillation, compared with 3 to 5 in sinus rhythm. Velocities and VTIs are averaged over consecutive, unselected beats, and paired measurements come from the same beats. In a stroke volume or output calculation, the VTI and the heart rate are averaged over the same cycles, because pairing the VTI of the beat after the longest cycle with an average rate overestimates output. An alternative is an index beat, one whose two preceding cycle lengths are similar, which approximates the average. Beats after a premature contraction are excluded from calculations such as the continuity equation and Qp/Qs, because their enhanced stroke volume corrupts any comparison with an ordinary beat. In atrial fibrillation, the A wave is absent, so E/A, Ar − A duration, and other A-wave-based variables are unavailable. Diastolic assessment then uses a separate multiparametric approach.

Doppler in critical care: stroke volume, fluid responsiveness, and low output

The LVOT VTI is the bedside surrogate of stroke volume. When the outflow diameter is fixed, change in VTI equals change in stroke volume, and the VTI multiplied by heart rate (minute distance) tracks cardiac output without the squared diameter error. At a normal heart rate, the LVOT VTI is about 17 to 23 cm. A VTI below 10 cm indicates a very low stroke volume and is associated with adverse outcomes in acute decompensated heart failure; in acute pulmonary embolism the association begins below 15 cm. A VTI that rises by more than about 15% after a fluid challenge indicates a positive response.

Fluid responsiveness is tested with dynamic maneuvers. In a meta-analysis of 21 studies, a rise in cardiac output of about 10% or more during passive leg raising, measured in real time by the outflow VTI or another continuous method, predicted fluid responsiveness with a pooled sensitivity of 85% and specificity of 91%. The test remains valid with spontaneous breathing and arrhythmia. In sedated patients with septic shock receiving controlled ventilation with preserved left ventricular function, a respiratory variation of 12% or more in peak aortic velocity by transesophageal Doppler separated responders from nonresponders. Respiratory variation requires controlled ventilation, regular rhythm, and adequate tidal volume, and it is invalid with spontaneous breathing efforts, atrial fibrillation, and right ventricular failure. The physiology of heart–lung interaction and pulse pressure variation is covered under fluid responsiveness in the cardiac intensive care unit, and invasive hemodynamic phenotypes of shock under hemodynamic phenotypes of cardiogenic shock.

Dynamic outflow obstruction is a Doppler finding that changes treatment in shock: a small, hyperdynamic ventricle with systolic anterior motion and a late-peaking outflow velocity during inotrope infusion indicates that the inotrope is worsening output. Doppler also identifies the mechanical causes of shock, such as a ventricular septal rupture with a left-to-right systolic jet, acute severe mitral regurgitation with a rapid fall in regurgitant velocity in late systole, and tamponade with exaggerated respiratory variation in mitral and tricuspid inflow. Tamponade is covered under pericardial effusion and cardiac tamponade.

Agreement between Doppler and right heart catheterization

Doppler and catheter measurements agree well when the Doppler signal is complete and the measurements are simultaneous, and less well in routine practice. In patients evaluated for pulmonary hypertension who had Doppler echocardiography within 1 hour of right heart catheterization, the mean difference in PASP was only −0.6 mm Hg, but the 95% limits of agreement were about ±40 mm Hg, and Doppler was inaccurate by more than 10 mm Hg in 48% of patients. Overestimation and underestimation were equally frequent, but underestimates were larger and more often misclassified severity. Cardiac output by Doppler had a mean difference of −0.1 L/min with limits of agreement of about ±2.3 L/min. Echocardiography therefore assigns probability and follows trends, and catheterization establishes the hemodynamic diagnosis.

VariableDoppler estimateInvasive counterpartMain sources of disagreement
Valve gradientPeak instantaneous and mean from CW envelopeSimultaneous LV and aortic pressures; peak-to-peak from pullbackPeak-to-peak timing; pressure recovery in a small aorta; nonsimultaneous study; misalignment
Valve areaContinuity equation (effective orifice area)Gorlin formula (anatomic-effective hybrid)LVOT diameter; low flow; regurgitation in Gorlin output; pressure recovery
Pulmonary artery systolic pressure4(TRV)² + RAPDirect PA pressureIncomplete envelope; RAP estimate; torrential TR; pulmonic obstruction
Mean PA pressure⅓ PASP + ⅔ PAEDP; early PR gradient; regressionDirect mean PA pressureErrors in two signals; pulmonary regurgitant signal absent in many patients
Left-sided filling pressureE/e′, TRV, LA volume and strain, pulmonary venous flowWedge pressure or LVEDPMitral disease, atrial fibrillation, constriction, pacing; result is categorical only
Cardiac outputLVOT CSA × VTI × heart rateThermodilution or FickDiameter squared; sample position; tricuspid regurgitation affects thermodilution; assumed oxygen consumption in Fick
Pulmonary vascular resistanceTRV ÷ RVOT VTI × 10 + 0.16(mPAP − wedge) ÷ cardiac outputUnreliable at high resistance; carries both input errors
Shunt ratioRVOT and LVOT stroke volumesOximetry Fick ratioRVOT diameter; regurgitation at a sampling site; mixed venous sampling

Doppler estimates and their invasive counterparts. LA, left atrial; PR, pulmonary regurgitant. Invasive technique and normal values are covered under echocardiographic estimates compared with invasive values and normal hemodynamic values.

Sources of error in Doppler hemodynamics

Errors propagate according to how an input enters an equation. A squared input doubles the relative error of the result, and an additive input shifts it by a fixed amount.

InputEnters asEffect of a 10% input errorDominant acquisition errorDerived values affected
Outflow or annular diameterSquareAbout 20%Unclear edges; wrong level; wrong phase; oblique planeSV, CO, AVA, Qp/Qs, regurgitant volume
Jet velocitySquareAbout 20%Beam misaligned; incomplete envelope; wrong jet sampledGradients and all jet-derived pressures
VTILinear10%Sample too close to or too far from the valve; angle; tracing the faint edgeSV, CO, AVA, DVI, Qp/Qs, PVR estimate
Heart rateLinear10%Rate from beats other than those measuredCardiac output
Right atrial pressureAdditiveFixed offset in mm HgCava misjudged; ventilation; athlete; abdominal pressureRVSP, PASP, PAEDP, mean PA pressure
Cuff pressureSubtractive referenceFixed offset, magnified when the jet gradient is largeCuff error; outflow obstruction; timingLAP, LVEDP, RVSP from VSD, PASP from PDA

Propagation of input errors into derived Doppler values. SV, stroke volume; CO, cardiac output.

Before reporting, a stroke volume is compared with ventricular size and function, a shunt ratio with the size of the receiving chambers, a valve area with the velocity, gradient, dimensionless index, and morphology, and a pulmonary pressure with right heart size and function. An implausible result most often reflects an invalid input. Review of such a result begins with the squared inputs, then sample position and alignment, then beat matching and units, and ends with the arithmetic.

References

  1. Quiñones MA, Otto CM, Stoddard M, Waggoner A, Zoghbi WA. Recommendations for quantification of Doppler echocardiography: a report from the Doppler Quantification Task Force of the Nomenclature and Standards Committee of the American Society of Echocardiography. J Am Soc Echocardiogr. 2002;15:167–184. doi:10.1067/mje.2002.120202
  2. Mitchell C, Rahko PS, Blauwet LA, et al. Guidelines for performing a comprehensive transthoracic echocardiographic examination in adults: recommendations from the American Society of Echocardiography. J Am Soc Echocardiogr. 2019;32:1–64. doi:10.1016/j.echo.2018.06.004
  3. Lang RM, Badano LP, Mor-Avi V, et al. Recommendations for cardiac chamber quantification by echocardiography in adults: an update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging. J Am Soc Echocardiogr. 2015;28:1–39.e14. doi:10.1016/j.echo.2014.10.003
  4. Baumgartner H, Hung J, Bermejo J, et al. Echocardiographic assessment of valve stenosis: EAE/ASE recommendations for clinical practice. J Am Soc Echocardiogr. 2009;22:1–23. doi:10.1016/j.echo.2008.11.029
  5. Baumgartner H, Hung J, Bermejo J, et al. Recommendations on the echocardiographic assessment of aortic valve stenosis: a focused update from the European Association of Cardiovascular Imaging and the American Society of Echocardiography. J Am Soc Echocardiogr. 2017;30:372–392. doi:10.1016/j.echo.2017.02.009
  6. Zoghbi WA, Adams D, Bonow RO, et al. Recommendations for noninvasive evaluation of native valvular regurgitation: a report from the American Society of Echocardiography developed in collaboration with the Society for Cardiovascular Magnetic Resonance. J Am Soc Echocardiogr. 2017;30:303–371. doi:10.1016/j.echo.2017.01.007
  7. Mukherjee M, Rudski LG, Addetia K, et al. Guidelines for the echocardiographic assessment of the right heart in adults and special considerations in pulmonary hypertension: recommendations from the American Society of Echocardiography. J Am Soc Echocardiogr. 2025;38:141–186. doi:10.1016/j.echo.2025.01.006. Correction: J Am Soc Echocardiogr. 2025;38:641.
  8. Nagueh SF, Sanborn DY, Oh JK, et al. Recommendations for the evaluation of left ventricular diastolic function by echocardiography and for heart failure with preserved ejection fraction diagnosis: an update from the American Society of Echocardiography. J Am Soc Echocardiogr. 2025;38:537–569. doi:10.1016/j.echo.2025.03.011
  9. Zoghbi WA, Jone PN, Chamsi-Pasha MA, et al. Guidelines for the evaluation of prosthetic valve function with cardiovascular imaging: a report from the American Society of Echocardiography developed in collaboration with the Society for Cardiovascular Magnetic Resonance and the Society of Cardiovascular Computed Tomography. J Am Soc Echocardiogr. 2024;37:2–63. doi:10.1016/j.echo.2023.10.004
  10. Silvestry FE, Cohen MS, Armsby LB, et al. Guidelines for the echocardiographic assessment of atrial septal defect and patent foramen ovale: from the American Society of Echocardiography and Society for Cardiac Angiography and Interventions. J Am Soc Echocardiogr. 2015;28:910–958. doi:10.1016/j.echo.2015.05.015
  11. Nagueh SF, Phelan D, Abraham T, et al. Recommendations for multimodality cardiovascular imaging of patients with hypertrophic cardiomyopathy: an update from the American Society of Echocardiography, in collaboration with the American Society of Nuclear Cardiology, the Society for Cardiovascular Magnetic Resonance, and the Society of Cardiovascular Computed Tomography. J Am Soc Echocardiogr. 2022;35:533–569. doi:10.1016/j.echo.2022.03.012
  12. Otto CM, Nishimura RA, Bonow RO, et al. 2020 ACC/AHA guideline for the management of patients with valvular heart disease: a report of the American College of Cardiology/American Heart Association Joint Committee on Clinical Practice Guidelines. Circulation. 2021;143:e72–e227. doi:10.1161/CIR.0000000000000923
  13. Ommen SR, Ho CY, Asif IM, et al. 2024 AHA/ACC/AMSSM/HRS/PACES/SCMR guideline for the management of hypertrophic cardiomyopathy: a report of the American Heart Association/American College of Cardiology Joint Committee on Clinical Practice Guidelines. Circulation. 2024;149:e1239–e1311. doi:10.1161/CIR.0000000000001250. Correction: Circulation. 2024;150:e198.
  14. Gurvitz M, Krieger EV, Fuller S, et al. 2025 ACC/AHA/HRS/ISACHD/SCAI guideline for the management of adults with congenital heart disease: a report of the American College of Cardiology/American Heart Association Joint Committee on Clinical Practice Guidelines. Circulation. 2026;153:e115–e251. doi:10.1161/CIR.0000000000001402. Correction: Circulation. 2026;153:e1115.
  15. Stout KK, Daniels CJ, Aboulhosn JA, et al. 2018 AHA/ACC guideline for the management of adults with congenital heart disease. Circulation. 2019;139:e698–e800. doi:10.1161/CIR.0000000000000603
  16. Humbert M, Kovacs G, Hoeper MM, et al. 2022 ESC/ERS guidelines for the diagnosis and treatment of pulmonary hypertension. Eur Heart J. 2022;43:3618–3731. doi:10.1093/eurheartj/ehac237. Corrigendum: Eur Heart J. 2023;44:1312.
  17. Hatle L, Angelsen B, Tromsdal A. Noninvasive assessment of atrioventricular pressure half-time by Doppler ultrasound. Circulation. 1979;60:1096–1104. doi:10.1161/01.cir.60.5.1096
  18. Yock PG, Popp RL. Noninvasive estimation of right ventricular systolic pressure by Doppler ultrasound in patients with tricuspid regurgitation. Circulation. 1984;70:657–662. doi:10.1161/01.cir.70.4.657
  19. Currie PJ, Seward JB, Chan KL, et al. Continuous wave Doppler determination of right ventricular pressure: a simultaneous Doppler-catheterization study in 127 patients. J Am Coll Cardiol. 1985;6:750–756. doi:10.1016/s0735-1097(85)80477-0
  20. Currie PJ, Seward JB, Reeder GS, et al. Continuous-wave Doppler echocardiographic assessment of severity of calcific aortic stenosis: a simultaneous Doppler-catheter correlative study in 100 adult patients. Circulation. 1985;71:1162–1169. doi:10.1161/01.cir.71.6.1162
  21. Masuyama T, Kodama K, Kitabatake A, et al. Continuous-wave Doppler echocardiographic detection of pulmonary regurgitation and its application to noninvasive estimation of pulmonary artery pressure. Circulation. 1986;74:484–492. doi:10.1161/01.cir.74.3.484
  22. Kitabatake A, Inoue M, Asao M, et al. Noninvasive evaluation of pulmonary hypertension by a pulsed Doppler technique. Circulation. 1983;68:302–309. doi:10.1161/01.cir.68.2.302
  23. Chemla D, Castelain V, Humbert M, et al. New formula for predicting mean pulmonary artery pressure using systolic pulmonary artery pressure. Chest. 2004;126:1313–1317. doi:10.1378/chest.126.4.1313
  24. Abbas AE, Fortuin FD, Schiller NB, et al. A simple method for noninvasive estimation of pulmonary vascular resistance. J Am Coll Cardiol. 2003;41:1021–1027. doi:10.1016/s0735-1097(02)02973-x
  25. Brennan JM, Blair JE, Goonewardena S, et al. Reappraisal of the use of inferior vena cava for estimating right atrial pressure. J Am Soc Echocardiogr. 2007;20:857–861. doi:10.1016/j.echo.2007.01.005
  26. Fisher MR, Forfia PR, Chamera E, et al. Accuracy of Doppler echocardiography in the hemodynamic assessment of pulmonary hypertension. Am J Respir Crit Care Med. 2009;179:615–621. doi:10.1164/rccm.200811-1691OC
  27. Bargiggia GS, Bertucci C, Recusani F, et al. A new method for estimating left ventricular dP/dt by continuous wave Doppler-echocardiography: validation studies at cardiac catheterization. Circulation. 1989;80:1287–1292. doi:10.1161/01.cir.80.5.1287
  28. Kolias TJ, Aaronson KD, Armstrong WF. Doppler-derived dP/dt and −dP/dt predict survival in congestive heart failure. J Am Coll Cardiol. 2000;36:1594–1599. doi:10.1016/s0735-1097(00)00908-6
  29. Baumgartner H, Stefenelli T, Niederberger J, Schima H, Maurer G. “Overestimation” of catheter gradients by Doppler ultrasound in patients with aortic stenosis: a predictable manifestation of pressure recovery. J Am Coll Cardiol. 1999;33:1655–1661. doi:10.1016/s0735-1097(99)00066-2
  30. Garcia D, Pibarot P, Dumesnil JG, et al. Assessment of aortic valve stenosis severity: a new index based on the energy loss concept. Circulation. 2000;101:765–771. doi:10.1161/01.cir.101.7.765
  31. Feissel M, Michard F, Mangin I, et al. Respiratory changes in aortic blood velocity as an indicator of fluid responsiveness in ventilated patients with septic shock. Chest. 2001;119:867–873. doi:10.1378/chest.119.3.867
  32. Monnet X, Marik P, Teboul JL. Passive leg raising for predicting fluid responsiveness: a systematic review and meta-analysis. Intensive Care Med. 2016;42:1935–1947. doi:10.1007/s00134-015-4134-1
  33. Blanco P. Rationale for using the velocity-time integral and the minute distance for assessing the stroke volume and cardiac output in point-of-care settings. Ultrasound J. 2020;12:21. doi:10.1186/s13089-020-00170-x