CardioBoardExam.com

Library › Imaging › MUGA, MIBG, and phase analysis

Radionuclide ventriculography, MIBG innervation imaging, and phase analysis

Equilibrium and first-pass radionuclide ventriculography, iodine-123 MIBG imaging of cardiac sympathetic innervation, and phase analysis of gated nuclear studies, from tracer and acquisition through quantification, clinical use, and reporting.

Equilibrium radionuclide angiography measures ejection fraction from the change in blood-pool counts between end-diastole and end-systole, without assumptions about ventricular shape, and serial measurements in one laboratory vary by less than 5 percentage points. Iodine-123 metaiodobenzylguanidine (MIBG) reports the integrity of cardiac sympathetic nerve terminals. A delayed heart-to-mediastinum ratio of 1.6 or more under the validated US acquisition identifies lower 1- and 2-year mortality in heart failure with an ejection fraction of 35% or less; lower ratios carry progressively higher mortality. Phase analysis of gated studies measures mechanical dyssynchrony, which describes contraction timing but does not by itself select patients for resynchronization.

Nuclear measurements beyond myocardial perfusion

Radionuclide ventriculography, sympathetic innervation imaging, and phase analysis share the gamma camera and the electrocardiographic gate with myocardial perfusion imaging, but none of them measures myocardial blood flow. Radionuclide ventriculography places the tracer inside the blood pool, so the ventricular cavity itself is the signal and its counts are proportional to its volume. MIBG is a norepinephrine analog that enters presynaptic sympathetic nerve terminals by the same transporter that recovers released norepinephrine, so myocardial retention reports the number and function of intact terminals. Phase analysis is a processing method applied to any gated dataset, perfusion or blood pool, that converts the regional count change through the cardiac cycle into the timing of regional contraction.

The three techniques answer different clinical questions. Radionuclide ventriculography answers how large the ventricles are and how much of their volume they eject, with a reproducibility that suits serial monitoring during cardiotoxic cancer therapy and decisions that turn on a few percentage points of ejection fraction. MIBG answers whether the sympathetic innervation of a failing or injured ventricle is preserved, a question with prognostic weight in heart failure and diagnostic weight in Lewy body disease. Phase analysis answers whether the ventricle contracts synchronously and where contraction occurs last.

TechniqueTracer and signalPrincipal outputsMain clinical uses
Equilibrium radionuclide angiography (gated blood-pool imaging, MUGA)Autologous red cells labeled with technetium-99m (Tc-99m); cavity counts through an electrocardiogram (ECG)-gated composite cycleCount-based left ventricular ejection fraction; regional wall motion; filling rates; with single-photon emission computed tomography (SPECT), biventricular volumes and right ventricular ejection fractionSerial ejection fraction during anthracycline or HER2-targeted therapy; cardiomyopathy and valve disease when echocardiography is limited
First-pass radionuclide angiographyCompact bolus of a Tc-99m agent recorded during its first transit through the heart and lungsRight and left ventricular ejection fraction separated in time; pulmonary transit; shunt detectionRight ventricular function; left-to-right shunt; function acquired at the time of a perfusion injection
I-123 MIBG imagingNorepinephrine analog taken up by the uptake-1 transporter and stored in vesiclesEarly and delayed heart-to-mediastinum ratio; washout rate; regional SPECT defectsRisk stratification in heart failure; arrhythmic risk research; Parkinson disease and dementia with Lewy bodies
Phase analysisFirst-harmonic Fourier fit of regional count change in any gated SPECT, positron emission tomography (PET), or blood-pool studyPhase histogram, phase standard deviation, histogram bandwidth, entropy; site of latest contractionMechanical dyssynchrony; left ventricular lead targeting in resynchronization research

Nuclear techniques that measure ventricular function, sympathetic innervation, and contraction timing. MUGA, multigated acquisition; HER2, human epidermal growth factor receptor 2.

Red blood cell labeling for blood-pool imaging

Technetium-99m bound to the patient's own erythrocytes remains in the vascular space for the duration of the study. Labeling requires stannous ion: tin enters the red cell and reduces pertechnetate that diffuses in afterward, and the reduced technetium binds to the beta chain of hemoglobin. The 2020 Society of Nuclear Medicine and Molecular Imaging (SNMMI) procedure standard and European Association of Nuclear Medicine (EANM) guideline for gated equilibrium radionuclide angiography gives labeling efficiencies of 60% to 70% for the in vivo method. This method uses stannous pyrophosphate at about 10 to 20 μg/kg intravenously, then pertechnetate 20 to 30 minutes later. The efficiency is about 90% for the mixed in vivo/in vitro method and above 97% for in vitro labeling with a commercial kit. The guideline strongly recommends the in vitro method for its efficiency (Farrell 2020). The recommended adult activity is 555 to 1,110 MBq (15 to 30 mCi), with up to 35 mCi for stress acquisitions with all-purpose collimators or for obese patients.

Unbound pertechnetate raises background in thyroid, gastric mucosa, salivary glands, and soft tissue, which lowers the contrast between the cavity and its surroundings and makes the background correction, and therefore the ejection fraction, less reliable. Gastric or thyroid activity on a blood-pool image indicates poor labeling. Drugs and conditions that reduce labeling (heparin, hydralazine, methyldopa, penicillin, quinidine, digoxin, prazosin, propranolol, doxorubicin, iodinated contrast, dextrose, low hematocrit, recent transfusion, red-cell antibodies) are listed in the radiation safety and radiopharmacy hub. That hub also covers the commercial kit procedure and the controls against reinjecting blood into the wrong patient. Tracer is not injected through lines that carry heparin or dextrose.

Acquisition of equilibrium radionuclide angiography

Gating. After the labeled cells equilibrate, the camera records counts while the electrocardiogram divides the R-R interval into frames. Counts from hundreds of accepted beats are summed frame by frame into one composite cardiac cycle. The gate triggers on the R wave, and electrodes are placed to give a tall monophasic R wave with small P and T waves; a T wave that triggers the gate produces an uninterpretable volume curve. The SNMMI/EANM standard requires at least 16 frames per R-R interval and prefers 24 to 32. It prefers 32 for stress images, because systolic and diastolic events occupy a short fraction of the cycle at higher heart rates (Farrell 2020).

Beat acceptance. A window of the mean R-R interval ±10% to 15% is common for planar systolic function, and ±15% to 35% for SPECT acquisitions, with wider windows in irregular rhythms. Beats outside the window are rejected. When accepted beats of different lengths are summed, late frames receive counts from fewer cycles and the end of the volume curve falls off (frame dropout). End-diastolic counts, the ejection fraction, and all diastolic indexes become unreliable. List-mode acquisition stores all beats with their timing, so the window can be set after acquisition and beats can be sorted for diastolic analysis.

Views and positioning. The left anterior oblique view at about 45°, adjusted to the angle that best separates the ventricles (the best septal view), is the single view used to calculate ejection fraction. On a correctly angled view the photopenic septum runs vertically from 12 o'clock to 6 o'clock. A caudal tilt of 10° to 15° separates the atria from the ventricles; a slant-hole collimator serves the same purpose. The anterior view (about 45° more anterior) displays the anterolateral wall and apex, and the lateral or left posterior oblique view displays the inferior and basal anterior walls. The zoom is set so that the heart fills about half of the field of view, and the camera is placed as close to the chest as habitus allows.

Counts and collimation. A low-energy high-resolution collimator is usual for rest-only studies. A low-energy all-purpose collimator is common for stress studies, and when rest and stress are compared, both are acquired with the same collimator. A total of 3 to 7 million counts is typical, and at least 200,000 counts per frame is recommended for a 16-frame resting study with a high-resolution collimator. The energy window is centered on 140 keV with a ±10% width.

SPECT blood-pool imaging. Tomographic acquisition (commonly 60 to 64 projections over 180° with a dual-head camera, 16 frames per cycle) isolates both ventricles from the atria and great vessels and allows volumetric left and right ventricular ejection fractions without background subtraction. Cadmium-zinc-telluride (CZT) cameras shorten acquisition or lower the administered activity. Planar and SPECT ejection fractions correlate well but are not interchangeable, and serial studies use one method.

ParameterPlanar equilibrium studySPECT equilibrium study
Administered activity (adult)555–1,110 MBq (15–30 mCi) Tc-99m red cellsSame; lower with CZT cameras
Frames per R-R interval≥16 (24–32 preferred; 32 at stress)16
Beat acceptance windowMean R-R ±10%–15%Mean R-R ±15%–35%
Views or projectionsBest septal left anterior oblique (about 45°, caudal tilt 10°–15°); anterior; lateral or left posterior oblique60–64 projections over 180° (dual head)
Counts3–7 million total; ≥200,000 per frame (16 frames, high-resolution collimator)Per protocol and camera
Ejection fraction methodBackground-corrected counts in end-diastolic and end-systolic regionsVolumetric from three-dimensional boundaries; no background correction
Right ventricular ejection fractionNot reliably quantifiedQuantified; lower limit about 40%

Acquisition parameters for gated equilibrium radionuclide angiography from the 2020 SNMMI procedure standard/EANM guideline (Farrell 2020). CZT, cadmium-zinc-telluride.

Count-based ejection fraction and background correction

Because counts in the left ventricular region are proportional to the blood volume within it, ejection fraction follows from counts alone:

Left ventricular ejection fraction (LVEF, %) = (background-corrected end-diastolic counts − background-corrected end-systolic counts) ÷ background-corrected end-diastolic counts × 100.

No geometric model of the ventricle is involved, which is why the method remains valid in a dilated, spherical, or aneurysmal ventricle. Such a ventricle violates the ellipsoid assumptions of two-dimensional echocardiography and the surface-fitting assumptions of gated perfusion imaging. The measurement still depends on four inputs:

Background. Counts in the left ventricular region include activity in the lung, chest wall, and myocardium in front of and behind the cavity. That background does not change with ventricular volume, so it is subtracted from both end-diastolic and end-systolic counts, scaled by the number of pixels in the corresponding region. The background region is placed adjacent to the lateral or inferoapical wall, between the 2 o'clock and 5 o'clock positions, a few pixels outside the end-systolic border. A background region over the spleen or descending aorta overestimates background and therefore overestimates ejection fraction; a background region placed outside the body underestimates background and underestimates ejection fraction. Including the left atrium in the ventricular region lowers ejection fraction, because atrial counts rise in ventricular systole.

Volumes. Planar studies can estimate absolute volumes from counts by measuring the count rate in a blood sample of known volume and correcting for attenuation, but the method is cumbersome and rarely used clinically. SPECT blood-pool imaging measures end-diastolic and end-systolic volumes from three-dimensional boundaries.

Normal values and interpretation of the gated blood-pool study

The cine displays of all views are reviewed before any number is accepted. Interpretation covers the relative size of the ventricles, the atria, and the great vessels, and the regional wall motion of the individual segments, graded as normal, mildly, moderately, or severely hypokinetic, akinetic, or dyskinetic. It also covers the thickness of the photopenic rim between the cavity and the lungs, which separates left ventricular hypertrophy from a pericardial effusion, and extracardiac activity in the stomach, thyroid, spleen, or a hemangioma.

MeasurementReference value or criterionSource and comment
Left ventricular ejection fraction (planar)≥50%SNMMI/EANM 2020; laboratory-specific normal limits are preferred
Right ventricular ejection fraction (SPECT)≥40%Generally regarded as the lower limit; not systematically validated
Peak filling rate (planar)>2.5 end-diastolic volumes per secondRequires adequate framing and a consistent rhythm
Exercise responseRise in LVEF of ≥5 percentage pointsA smaller rise or a fall, or a new regional abnormality, is abnormal
Significant change between serial studies≥5 percentage pointsSame laboratory, camera, labeling method, and processing

Reference values for equilibrium radionuclide angiography (Farrell 2020). Ejection fraction thresholds for cancer therapy–related cardiac dysfunction are defined separately and are listed below.

Regional function and aneurysm. The left anterior oblique view shows the septum, inferolateral wall, and apex; the anterior and lateral views show the remaining walls, as described above. A left ventricular aneurysm appears as a dyskinetic segment whose counts rise in systole, and its timing on phase imaging is about 180° from the rest of the ventricle. Because the method is count-based, a large aneurysm does not distort the ejection fraction calculation; it lowers the true global value, and the regional display shows where.

Stroke count ratio. In the absence of shunting, left and right ventricular stroke volumes are equal. The ratio of left to right ventricular stroke counts rises with mitral or aortic regurgitation and was used historically to estimate regurgitant volume. Chamber overlap on planar images limits its accuracy, and echocardiography and magnetic resonance have replaced it.

Diastolic indices from the time–activity curve

The left ventricular time–activity curve, displayed from end-diastole through ejection and filling, carries diastolic information in its shape. The peak filling rate is the steepest upslope of the curve in early diastole, normalized to end-diastolic counts and expressed in end-diastolic volumes per second; a value above 2.5 is normal on planar studies. The time to peak filling, the fraction of filling completed in the first third of diastole, and the atrial contribution to filling are other indices. Slower and later filling reflects impaired relaxation and reduced compliance and can precede a fall in ejection fraction in cardiomyopathy, hypertrophy, and coronary disease.

Filling indices depend on heart rate, age, loading conditions, and medications, and they demand more of the acquisition than ejection fraction does. At least 24 to 32 frames, or list-mode data, are needed to sample the rapid filling phase; arrhythmias and frame dropout corrupt the late part of the curve first; and correlation between planar and SPECT diastolic measurements is only modest. The 2014 American Society of Echocardiography and European Association of Cardiovascular Imaging (ASE/EACVI) consensus noted that the variability of radionuclide diastolic measurements limits their use in cardio-oncology (Plana 2014). Diastolic function is now graded by echocardiography in most patients, as described in the heart failure with preserved ejection fraction hub.

Right ventricular function and first-pass radionuclide angiography

Why the right ventricle is difficult on equilibrium images. On a planar left anterior oblique view the right ventricle overlaps the right atrium and pulmonary outflow tract, its irregular crescentic shape makes the region of interest uncertain, and background is hard to define. The SNMMI/EANM standard states that right ventricular ejection fraction cannot be reliably quantified from planar equilibrium images. SPECT blood-pool imaging separates the chambers and measures right ventricular volumes and ejection fraction, with about 40% as the lower limit of normal (Farrell 2020).

First-pass method. First-pass radionuclide angiography records a compact intravenous bolus during its initial transit through the superior vena cava, right atrium, right ventricle, lungs, left atrium, and left ventricle, before the tracer mixes in the blood pool. Because the chambers are opaque at different times, the right ventricle is measured while the left heart contains little activity, which makes first pass the radionuclide method of choice for right ventricular ejection fraction (Friedman 2006). The study needs a tight bolus injected into a large proximal vein, a camera with a high count-rate capability, and acquisition in the anterior or shallow right anterior oblique view. A fragmented bolus, a peripheral injection, or count-rate losses at the bolus peak degrade it. Any Tc-99m agent can be used, so a first-pass study can be acquired at the moment of a perfusion tracer injection, and the left ventricular ejection fraction can be measured at peak exercise. Dedicated multicrystal and solid-state cameras handle the count rate best.

Shunts and transit. A time–activity curve over the lung normally rises and falls smoothly before systemic recirculation. In a left-to-right shunt, early recirculation of tracer through the lungs distorts the downslope, and fitting the first and recirculation components estimates the pulmonary-to-systemic flow ratio. A right-to-left shunt produces early systemic activity, for example in the kidneys or brain on macroaggregated albumin studies. Echocardiography and magnetic resonance now quantify most shunts.

Clinical use. Right ventricular assessment before implantation of a left ventricular assist device is a current indication listed by the SNMMI/EANM standard, because right ventricular failure is a major complication of left ventricular support. Right ventricular ejection fraction also carries prognostic information in pulmonary hypertension and heart failure; cardiac magnetic resonance is the reference method when it is available.

Exercise and pharmacologic stress radionuclide angiography

Stress equilibrium imaging is acquired during supine (most often) or upright bicycle exercise. Acquisition begins about 1 minute into a stage and continues for at least 2 to 3 minutes at peak stress, with the patient held in the best septal view throughout. A normal response is a rise in left ventricular ejection fraction of at least 5 percentage points; a smaller rise, a fall, or a new regional wall motion abnormality indicates ischemia or impaired contractile reserve. Dobutamine is the pharmacologic agent; vasodilator stress has low accuracy for blood-pool imaging and is rarely used. Contraindications follow those of exercise and dobutamine stress testing, and stress blood-pool imaging is not performed in acute coronary syndromes.

Before perfusion imaging and stress echocardiography became widespread, exercise radionuclide angiography was a standard test for coronary disease, and submaximal exercise studies within 2 weeks of myocardial infarction carried prognostic value. Motion between rest and stress positions, the impossibility of recording true peak function after treadmill exercise, and lower diagnostic performance have confined it to research and occasional clinical use (Farrell 2020). Measurement of contractile reserve was also proposed to detect anthracycline cardiotoxicity earlier than resting ejection fraction, but limited exercise capacity, the need for a supine bicycle, and low specificity have kept it from routine use (Plana 2014). Stress testing for ischemia is covered in the exercise stress testing and pharmacologic stress testing hubs.

Accuracy and reproducibility compared with echocardiography and cardiac magnetic resonance

Reproducibility. Inter- and intraobserver variability of the equilibrium ejection fraction is below 5 percentage points, so a change of 5 points between two studies in one laboratory represents a real change (Farrell 2020). The ASE/EACVI consensus attributes this to a count-based, three-dimensional measurement made largely by software, and notes that serial radionuclide measurements have lower variability than qualitative two-dimensional echocardiographic estimates (Plana 2014). Among echocardiographic methods, noncontrast three-dimensional echocardiography had the lowest temporal variability in women receiving chemotherapy, about 6 percentage points, compared with more than 10 points for two-dimensional methods (Thavendiranathan 2013).

Accuracy. Reproducibility is not the same as accuracy. In 75 patients with cancer who had a clinical radionuclide study and cardiac magnetic resonance within 30 days, the mean radionuclide ejection fraction was only 1.5 points lower than the magnetic resonance value (48.5% and 50.0%). The 95% limits of agreement, however, were wide, from −19.4 to 16.5 points, and 35% of patients were classified differently at a 50% threshold and 20% at a 55% threshold (Huang 2017). The ASE/EACVI document adds that early reproducibility data came from small-field, single-head cameras that could be angled for the best septal and caudal views. Current large-field dual-head cameras often cannot be positioned as well, so historical reproducibility may not transfer to all contemporary laboratories (Plana 2014).

Serial comparison across modalities. Ejection fractions from different modalities are not interchangeable. Serial decisions are made from one modality, ideally in one laboratory with one camera, one labeling method, and one processing approach. A change in ejection fraction that coincides with a change of method is not interpreted as a change in the patient until it is confirmed by the original method.

FeatureEquilibrium radionuclide angiographyTwo-dimensional echocardiographyThree-dimensional echocardiography with strainCardiac magnetic resonance
Basis of ejection fractionCounts; no geometric assumptionBiplane disk summation; geometric assumptionsVolumetric; semiautomated bordersVolumetric short-axis stack; reference standard
Serial variability<5 points (same laboratory)More than 10 pointsAbout 6 pointsLow; reference standard for volumes
Additional informationRegional motion, filling rate, phase; little structural detailValves, pericardium, diastolic function, right ventricle, strainGlobal longitudinal strain detects subclinical dysfunctionTissue characterization (edema, fibrosis, infiltration)
Ionizing radiationYes (about 3.5–5.2 mSv per study)NoNoNo
Main limitationsRadiation; camera positioning; labeling; arrhythmiaAcoustic windows; foreshortening; observer variabilityImage quality; availability; expertiseCost; availability; some devices; claustrophobia

Comparison of methods for serial left ventricular ejection fraction. Variability figures from Farrell 2020 and Thavendiranathan 2013; dose from the SNMMI/EANM effective dose coefficient of 0.0047 mSv/MBq at 20 to 30 mCi.

Sources of error in radionuclide ventriculography

Radiation dose of blood-pool imaging

The effective dose coefficient of Tc-99m-labeled red cells is 0.0047 mSv/MBq in adults, with the urinary bladder wall receiving the highest organ dose (Farrell 2020). An administered activity of 740 MBq (20 mCi) therefore gives about 3.5 mSv and 1,110 MBq (30 mCi) about 5.2 mSv; the ASE/EACVI consensus cites 5 to 10 mSv for 20 to 30 mCi using older coefficients (Plana 2014). The label schedule for adjuvant trastuzumab implies about 9 studies over 3 years, roughly 30 to 45 mSv if all are blood-pool studies, which is one reason echocardiography is the first-line monitoring method in cardio-oncology. In pregnancy, echocardiography or magnetic resonance is used for ventricular function. After a blood-pool study, the SNMMI/EANM standard advises interruption of breastfeeding for 12 to 24 hours. Dose estimation and comparison with other nuclear protocols are covered in the radiation safety hub.

Definitions of cancer therapy–related cardiac dysfunction

Serial imaging during cancer therapy exists to detect cancer therapy–related cardiac dysfunction (CTRCD) early enough to change treatment. The definitions have changed over time, and the threshold applied depends on the document used. The International Cardio-Oncology Society (IC-OS) consensus of 2022 grades asymptomatic CTRCD by ejection fraction, global longitudinal strain, and cardiac biomarkers, and symptomatic CTRCD by heart failure severity. The 2022 European Society of Cardiology (ESC) cardio-oncology guideline adopted these definitions (Herrmann 2022; Lyon 2022). The 2014 ASE/EACVI consensus defined CTRCD as a decrease in ejection fraction of more than 10 percentage points to a value below 53%, the lower limit for two-dimensional echocardiography, confirmed by repeat imaging 2 to 3 weeks later (Plana 2014).

CategoryIC-OS 2022 and ESC 2022 definition
Asymptomatic, mildLVEF ≥50% with a new relative decline in global longitudinal strain of more than 15% from baseline and/or a new rise in cardiac troponin or natriuretic peptide
Asymptomatic, moderateNew LVEF reduction of ≥10 percentage points to 40%–49%; or a reduction of <10 points to 40%–49% with a new relative decline in global longitudinal strain of more than 15% and/or a new rise in biomarkers
Asymptomatic, severeNew LVEF reduction to <40%
Symptomatic, mild to very severeHeart failure with supportive ejection fraction and biomarkers, graded from mild symptoms without intensified therapy (mild), through outpatient intensification of diuretic and heart failure therapy (moderate) and hospitalization (severe), to inotropic or mechanical support or transplant evaluation (very severe)

Definitions of cancer therapy–related cardiac dysfunction (Herrmann 2022; Lyon 2022). The IC-OS document bases ejection fraction values on two-dimensional echocardiography. Strain is not measured on blood-pool images, so a radionuclide study cannot apply the strain criterion. It can classify moderate and severe asymptomatic dysfunction by ejection fraction, and mild dysfunction only with a new rise in troponin or natriuretic peptide.

The ejection fraction categories were written for echocardiography, so a laboratory that monitors with blood-pool imaging applies them to its own baseline with its own method and does not mix values from different modalities. Recovery is classified against baseline in the ASE/EACVI consensus. Recovery to within 5 points of baseline is classified as reversible. Improvement of 10 or more points from the nadir, with the value remaining more than 5 points below baseline, is classified as partially reversible. Improvement of less than 10 points from the nadir, with the value remaining more than 5 points below baseline, is classified as irreversible.

Serial ejection fraction monitoring during anthracycline and HER2-targeted therapy

Origins. Radionuclide angiography was used from the late 1970s to detect anthracycline injury before heart failure appeared. In 1,487 patients monitored with serial resting studies over 7 years, monitoring and discontinuation criteria were derived for doxorubicin. In a retrospective analysis of 282 high-risk patients from that cohort, those managed in agreement with the criteria had a lower incidence of clinical heart failure than those managed otherwise (2.9% and 20.8%), a fourfold reduction after adjustment for other predictors (Schwartz 1987). These criteria remain in the SNMMI/EANM standard as the basis for blood-pool monitoring of anthracycline therapy.

Baseline LVEFMonitoring scheduleDiscontinuation criterion
Normal (≥50%)Baseline study; repeat at a cumulative doxorubicin dose of 250–300 mg/m²; repeat at 450 mg/m² (400 mg/m² with high-risk features); then before any dose above 450 mg/m²LVEF decrease of ≥10 percentage points from baseline to a value below 50%
Abnormal (>30% to <50%)Baseline study; repeat before all subsequent dosesLVEF decrease of ≥10 points from baseline, or LVEF ≤30%
≤30%Therapy not startedNot applicable

Criteria for serial radionuclide monitoring of doxorubicin therapy, as reproduced in the 2020 SNMMI/EANM standard (Schwartz 1987; Farrell 2020). High-risk features: cyclophosphamide, heart disease, mediastinal radiation, and an abnormal electrocardiogram. These criteria predate current definitions and modern cardioprotective therapy.

HER2-targeted therapy. The US trastuzumab label requires measurement of LVEF by echocardiogram or radionuclide angiography at these times: immediately before treatment; at 3-month intervals during treatment and at its completion; at 4-week intervals while the drug is withheld for left ventricular dysfunction; and at 6-month intervals for at least 2 years after completion of adjuvant therapy. Trastuzumab is withheld for at least 4 weeks after an absolute decrease in LVEF of 16 percentage points or more from the pretreatment value. It is also withheld for at least 4 weeks when the LVEF falls below the institutional lower limit of normal with an absolute decrease of 10 points or more. It may be resumed if, within 4 to 8 weeks, the LVEF returns to normal limits and the absolute decrease from baseline is 15 points or less. It is permanently discontinued for a decline persisting more than 8 weeks or for more than 3 interruptions for cardiomyopathy (Herceptin prescribing information). The 2022 ESC guideline supports continuing HER2-targeted therapy in asymptomatic mild CTRCD and, with heart failure therapy and close cardiac monitoring, in asymptomatic moderate CTRCD (LVEF 40% to 49%), which is more permissive than the label.

Choice of modality. The 2017 American Society of Clinical Oncology (ASCO) guideline recommends echocardiography as the imaging test for monitoring and for diagnosis. It names cardiac magnetic resonance or radionuclide angiography as alternatives when echocardiography is unavailable or technically inadequate and prefers magnetic resonance between the two (Armenian 2017). The 2022 ESC guideline places echocardiography, with global longitudinal strain, and cardiac biomarkers first, and magnetic resonance when echocardiography is unavailable or nondiagnostic. Multigated acquisition imaging is a third-line modality when both are unavailable and is avoided where possible because of radiation (Lyon 2022). Blood-pool imaging is chosen when acoustic windows are poor (after mastectomy, reconstruction, or chest radiation) or when magnetic resonance is unavailable or contraindicated. It is also chosen when a device or body habitus limits other methods, or when a laboratory has years of radionuclide baselines in a patient whose management depends on small serial changes. It provides little information on valves, the pericardium, strain, or tissue composition, and it adds radiation.

Phase analysis in cardio-oncology. In 177 women with breast cancer, the approximate entropy of the baseline radionuclide phase image was higher in the 11 who later had a decline in LVEF of more than 10 points to below 50%. Combining entropy with baseline LVEF improved discrimination (Jones 2022). This single-center retrospective finding has not entered guidelines.

The heart failure with reduced ejection fraction hub covers treatment once dysfunction is established; immune checkpoint inhibitor myocarditis is imaged with magnetic resonance and fluorodeoxyglucose (FDG) PET, as described in the cardiac FDG PET hub.

Other indications for blood-pool imaging

The SNMMI/EANM standard lists these indications beyond cardio-oncology: timing of surgery and assessment of treatment in valvular heart disease; biventricular function, type and severity of dysfunction, and diastolic function in cardiomyopathy; identification of candidates for a defibrillator or resynchronization therapy; ventricular function before and after heart transplantation; evaluation of right ventricular function; and determination of ventricular dyssynchrony. Diagnosis and prognosis of stable coronary disease with rest-stress studies are uncommon indications (Farrell 2020).

Blood-pool imaging is unaffected by acoustic windows, obesity, chest deformity, or pacing and defibrillator leads, and it gives a reproducible ejection fraction near a decision threshold, such as 35% for primary-prevention defibrillator eligibility. When echocardiography and magnetic resonance disagree or are nondiagnostic near such a threshold, a count-based measurement is a reasonable arbiter. Eligibility criteria for defibrillators are covered in the implantable cardioverter-defibrillator hub.

Cardiac sympathetic innervation and the norepinephrine analog MIBG

Physiology. Postganglionic sympathetic fibers from the stellate and thoracic ganglia run with the epicardial coronary arteries and penetrate the myocardium from the epicardium, densely innervating both ventricles. Norepinephrine is synthesized in the nerve terminal, stored in vesicles, and released into the synaptic cleft, where it binds beta-1, beta-2, and alpha-1 receptors on myocytes. Most released norepinephrine is recovered by the uptake-1 transporter, a sodium-dependent carrier on the presynaptic membrane, and repackaged into vesicles; the remainder is metabolized or spills into the circulation.

MIBG uptake and storage. Metaiodobenzylguanidine (iobenguane), a guanethidine analog, is accepted by the uptake-1 transporter and stored in vesicles like norepinephrine. It does not bind postsynaptic receptors and is not metabolized by monoamine oxidase or catechol-O-methyltransferase, so it accumulates and remains. Myocardial MIBG activity therefore reflects the number of intact, functioning terminals and the efficiency of transport and storage, without serving as a measure of myocardial blood flow. Labeled with iodine-123 (physical half-life about 13.2 hours, principal photon 159 keV), it can be imaged early and several hours later on the same day.

Disease states. In heart failure, sustained sympathetic activation increases norepinephrine release, reduces uptake-1 density and function, and depletes vesicular stores. The result is reduced cardiac MIBG retention and faster washout, both of which scale with the severity of the neurohormonal derangement. After myocardial infarction, sympathetic nerves are more sensitive to ischemia than myocytes, so the denervated territory extends beyond the scar into viable myocardium. Viable but denervated myocardium is supersensitive to circulating catecholamines and electrically heterogeneous, which is the rationale for studying innervation as a marker of arrhythmic risk. Denervation also occurs in diabetes, Parkinson disease, dementia with Lewy bodies, amyloidosis, and after heart transplantation.

Two anterior planar chest scintigrams after iodine-123 MIBG. On the left, the left ventricular myocardium is clearly visible above the liver. On the right, the heart is barely distinguishable from the mediastinum and lungs, while the liver is intense.
Anterior planar I-123 MIBG images. Left: normal cardiac uptake, with the left ventricular myocardium clearly above mediastinal and lung background. Right: severely reduced cardiac uptake, with the heart barely separable from background. Liver activity is prominent and thyroid activity is visible in both images. The images come from a multicenter study that compared dementia with Lewy bodies with Alzheimer disease. Credit: Yoshita M, Arai H, Arai H, et al. PLoS One 2015;10:e0120540, via Wikimedia Commons; CC BY 2.5.

Patient preparation: thyroid blockade and interfering medications

Thyroid blockade. Free radioiodine concentrates in the thyroid. The US label for iobenguane I-123 specifies potassium iodide oral solution or Lugol solution equivalent to 100 mg of iodide, or potassium perchlorate 400 mg, in adults at least 1 hour before injection. Blockade is individualized and may be omitted after thyroidectomy or in patients with very limited life expectancy (AdreView prescribing information).

Interfering medications. Any drug that blocks uptake-1, depletes vesicular stores, or competes for transport lowers myocardial MIBG retention regardless of the state of the nerves, and a higher tracer dose does not overcome the effect. The label names antihypertensives that deplete norepinephrine stores or inhibit reuptake (reserpine, labetalol), antidepressants that inhibit the norepinephrine transporter (tricyclics and their derivatives, and selective serotonin reuptake inhibitors), sympathomimetic amines (phenylephrine, phenylpropanolamine, pseudoephedrine, ephedrine), and cocaine. It advises discontinuation for at least 5 biological half-lives when clinically tolerated. It also states that many cardiovascular, pulmonary, and neuropsychiatric drugs interfere and that imaging is not performed when stopping them carries more risk than benefit. Heart failure therapy was continued in the AdreView Myocardial Imaging for Risk Evaluation in Heart Failure (ADMIRE-HF) study, in which 92% of patients took a beta-blocker and 93% an angiotensin-converting enzyme inhibitor or angiotensin receptor blocker.

Drug classExamplesMechanismTypical withdrawal interval
Tricyclic and related antidepressantsAmitriptyline, imipramine, nortriptyline, doxepin; venlafaxine; mirtazapineUptake-1 inhibition24–48 h (mirtazapine 8 days)
AntipsychoticsChlorpromazine, haloperidol, quetiapine, risperidone, olanzapine, clozapineUptake-1 inhibition24 h to 10 days; 1 month for depot preparations
Combined alpha- and beta-blockersLabetalolUptake-1 inhibition and vesicular depletion72 h
Adrenergic neuron blockersReserpine, guanethidineVesicular uptake inhibition and depletion48 h
Sympathomimetics and decongestantsPseudoephedrine, phenylephrine, ephedrine; brimonidineVesicular depletion24–48 h
Inotropes and vasopressorsDobutamine, dopamine, norepinephrineVesicular depletion24 h
Calcium channel blockersDiltiazem, nifedipine; amlodipine, felodipine, verapamilIncreased uptake and retention24–48 h
Opioid and stimulant drugsTramadol; cocaineUptake-1 inhibitionTramadol 24 h; cocaine 7–14 days
Antiarrhythmic drugsAmiodaroneUptake inhibition and depletionWithdrawal not practical; result reported with the limitation

Medications that alter myocardial MIBG uptake, after the EANM standardization proposal (Flotats 2010) and the 2025 review of cardiac MIBG practice (Peacock 2025). Intervals are guides; the US label specifies at least 5 biological half-lives for drugs known to reduce norepinephrine uptake.

Diet, kidney failure, pregnancy, and lactation. Foods containing vanillin or catecholamine-like compounds (chocolate, blue cheese) are avoided for several days in some protocols. Iobenguane is cleared by glomerular filtration and is not removed by dialysis, so severe kidney failure prolongs exposure and raises background. Radioiodine crosses the placenta and can impair fetal thyroid function; the label advises pumping and discarding breast milk for at least 6 days. The US product contains benzyl alcohol (10.3 mg/mL).

MIBG acquisition: activity, timing, collimator, and tomography

The adult activity is 370 MBq (10 mCi) of iobenguane I-123, injected intravenously over 1 to 2 minutes. The label gives an effective dose of 5.07 mSv for this activity. Anterior planar images of the chest are acquired early, at about 15 minutes, and late, at about 4 hours. For heart failure the label specifies the late image at 4 hours ±10 minutes with a low-energy high-resolution collimator and a 128 × 128 matrix, with the field including the heart and as much of the upper chest as possible (AdreView prescribing information). The ADMIRE-HF readers measured the heart-to-mediastinum ratio on images acquired 3 hours 50 minutes after injection. SPECT, with or without computed tomography, follows the late planar image when regional uptake is of interest.

Early and late images. The early image is recorded while tracer remains in the blood and transport into terminals is under way, so the early ratio reflects delivery and uptake-1 function. The late image follows blood-pool clearance, so remaining myocardial activity represents tracer taken up and retained in vesicles. The delayed ratio is the primary prognostic measurement; washout between the two images reflects sympathetic drive.

Collimator choice. I-123 emits a small fraction of higher-energy photons (above 400 keV) that penetrate the thin septa of low-energy collimators and scatter into the image. Penetration adds counts to the mediastinal background, which lowers the measured heart-to-mediastinum ratio and compresses the range between normal and abnormal hearts. Medium-energy collimators reduce penetration and give higher ratios with a wider range (Okuda 2023). The US label and the ADMIRE-HF threshold of 1.6, however, were defined with a low-energy high-resolution collimator, so the threshold applies only to that acquisition. Septal penetration and collimator design are covered in the nuclear cardiology physics hub.

Cross-calibration. Phantom-based conversion coefficients allow a ratio measured on one camera-collimator system to be converted to a standard reference condition. Measured coefficients were about 0.54 for low-energy, 0.74 for low-medium-energy, and 0.88 for medium-energy collimators, and machine-learning estimates from collimator geometry agreed with phantom values (Okuda 2023). Without such calibration, ratios from different laboratories or collimators are not compared, and serial studies preserve the original acquisition and analysis.

Heart-to-mediastinum ratio and washout rate

Heart-to-mediastinum ratio. The ratio is the mean counts per pixel in a cardiac region divided by the mean counts per pixel in an upper mediastinal region on the anterior planar image. The label method draws an irregular region along the epicardial border of the whole heart (or over its presumed location when the myocardium is not seen). A 7 × 7 pixel square is then placed in the upper mediastinum centered on the lowest-count pixel along a midline vertical line, starting 4 pixels below the level of the lung apices. Other laboratories use a circular cardiac region or a rectangular mediastinal region below the clavicular heads. The methods give slightly different values, so the method that defined a threshold is the method used to apply it.

Washout rate. The washout rate is the percentage of myocardial activity lost between the early and late images. It is commonly calculated with correction for background and for I-123 decay over the interval:

Washout (%) = [(Hearly − Mearly) − (Hlate − Mlate) ÷ decay factor] ÷ (Hearly − Mearly) × 100,

where H and M are mean counts per pixel in the heart and mediastinum, and the decay factor is 2−t/13.2 for an interval of t hours. Uncorrected and background-only formulas give different values, and washout is less reproducible than the delayed ratio because it combines the noise of two measurements.

IndexNormal range or thresholdPopulation and method
Delayed H/M, normalAbout 1.9 to 3.0Depends on collimator, region method, age; lower with low-energy collimators
Delayed H/M, ADMIRE-HF controlsMean 1.8 ± 0.2 (range 1.1–2.4)94 controls without heart disease; low-energy high-resolution collimator
Delayed H/M, ADMIRE-HF patientsMean 1.4 ± 0.2 (range 1.0–2.4)NYHA class II–III, LVEF ≤35%
Delayed H/M, prognostic threshold (US label)≥1.6 identifies lower 1- and 2-year mortalityLabel method; 4-hour image; low-energy high-resolution collimator
Delayed H/M, pooled Japanese cohorts≤1.68 higher risk; <1.25 mortality >7%/year; ≥1.95 <2%/year1,322 patients; values standardized across centers
Washout rate, normalAbout 21% to 37%Method-dependent; rises with age and sympathetic drive

Quantitative MIBG indices (AdreView prescribing information; Jacobson 2010; Nakata 2013; Peacock 2025). H/M, heart-to-mediastinum ratio; NYHA, New York Heart Association.

Visual reading. The label's visual criteria precede quantification: normal uptake shows the left ventricular myocardium distinctly in the left lower chest with more activity in the heart than in the adjacent lungs and mediastinum; reduced uptake shows the heart faintly or not at all. Liver activity below the heart and thyroid activity in the neck are expected; intense lung activity raises the apparent background.

Count-based ejection fraction, heart-to-mediastinum ratio, and washout calculator

The calculator applies the background-corrected count formula for ejection fraction, the heart-to-mediastinum ratio, and the background- and decay-corrected washout rate. Counts for the ejection fraction are total counts in a region with the number of pixels in the region; MIBG values are mean counts per pixel.

LVEF (count-based)—
Early H/M ratio—
Late H/M ratio—
Washout rate—
—

LVEF = (ED counts − background × ED pixels − [ES counts − background × ES pixels]) ÷ (ED counts − background × ED pixels) × 100. H/M = heart ÷ mediastinum mean counts per pixel. Washout = [(Hearly − Mearly) − (Hlate − Mlate) ÷ 2−t/13.2] ÷ (Hearly − Mearly) × 100. The 1.6 threshold applies only to the label acquisition with a low-energy high-resolution collimator and the label region method. ED, end-diastolic; ES, end-systolic; H, heart; M, mediastinum.

Prognosis in heart failure: ADMIRE-HF and pooled cohorts

ADMIRE-HF. The prospective multicenter ADMIRE-HF study imaged 961 patients with NYHA class II or III heart failure and an LVEF of 35% or less, on stable therapy, and followed them for up to 2 years with the imaging results withheld from clinicians (Jacobson 2010). The composite end point of NYHA class progression, potentially life-threatening arrhythmic event, or cardiac death occurred in 237 patients (25%) over a median of 17 months. The 2-year event rate was 15% with a delayed heart-to-mediastinum ratio of 1.60 or more and 37% below 1.60 (hazard ratio for a ratio ≥1.60, 0.40). Hazard ratios for the components were 0.49 for heart failure progression, 0.37 for arrhythmic events, and 0.14 for cardiac death. In multivariable analysis the ratio, LVEF, B-type natriuretic peptide, and NYHA class all contributed, and the ratio added discrimination across levels of natriuretic peptide and ejection fraction.

Label mortality data. The pooled ADMIRE-HF data underlie the US approval of iobenguane I-123 for "scintigraphic assessment of sympathetic innervation of the myocardium" in NYHA class II or III heart failure with an LVEF of 35% or less. The indication is to help identify patients with lower 1- and 2-year mortality risk by a ratio of 1.6 or more. The label states that utility has not been established for selecting a therapeutic intervention, for monitoring response to therapy, or for using the ratio to identify a patient at high risk of death (AdreView prescribing information).

Delayed H/M ratioPatients1-year mortality (95% CI)2-year mortality (95% CI)
≥1.62011.0% (0.0–2.4)3.3% (0.7–5.9)
1.2 to <1.66685.5% (3.8–7.3)11.5% (9.0–14.0)
<1.29213.4% (6.4–20.5)22.0% (13.2–30.8)

Mortality by delayed heart-to-mediastinum ratio in the two ADMIRE-HF trials (964 patients enrolled and 961 analyzed; 80% men; 66% ischemic heart disease), from the US iobenguane I-123 label. The trials excluded myocardial infarction within 30 days, functioning ventricular pacemakers, and prior defibrillation for an arrhythmic event. CI, confidence interval.

Pooled cohorts. A patient-level pool of 6 Japanese prospective cohorts (1,322 patients followed for a mean of 78 months) found age, NYHA class, delayed ratio, and LVEF to be independent predictors of all-cause death. In the subgroup with natriuretic peptide values, the ratio remained independent while LVEF did not. A ratio of 1.68 or less identified higher risk in all ejection fraction categories. Annual mortality exceeded 7% below 1.25 and was under 2% at 1.95 or more, and adding the ratio to clinical data gave a net reclassification improvement of 0.175 (Nakata 2013). A pooled individual-patient meta-analysis of 636 patients from European and US studies found the delayed ratio predictive over its full range for death, cardiac death, and transplantation, but not independently for arrhythmic events (Verschure 2014).

Place in practice. MIBG imaging provides prognostic information in heart failure. No appropriate use criteria have been developed for cardiac MIBG imaging (Peacock 2025), and no trial has shown that therapy selected by MIBG improves outcome. A low ratio identifies a patient whose risk exceeds that predicted by ejection fraction and natriuretic peptide alone and can inform the timing of advanced therapy evaluation. A high ratio indicates lower short-term mortality but does not remove an indication for guideline-directed therapy or a device. The 2021 EACVI/EANM expert document describes its use for risk stratification across heart failure and other conditions (Gimelli 2021).

Arrhythmic risk and regional denervation

The hypothesis that denervated but viable myocardium generates ventricular arrhythmias has been tested with both planar and tomographic innervation imaging. In ADMIRE-HF, a ratio of 1.60 or more carried a hazard ratio of 0.37 for potentially life-threatening arrhythmic events. In 116 patients referred for a defibrillator, a summed late MIBG SPECT defect score above 26 predicted appropriate device therapy (52% compared with 5% at 3 years) and the composite of appropriate therapy or cardiac death (57% compared with 10%) (Boogers 2010). The pooled individual-patient analysis, however, did not find the delayed ratio to be an independent predictor of arrhythmic events (Verschure 2014).

PET with carbon-11 hydroxyephedrine (HED) quantifies regional denervation with higher resolution. In the PAREPET study of 204 patients with ischemic cardiomyopathy and LVEF of 35% or less eligible for a primary-prevention defibrillator, the extent of denervated myocardium predicted sudden cardiac arrest independently of LVEF and infarct volume. Patients with sudden arrest had denervation of 33% of the left ventricle compared with 26% in those without. The highest tertile of denervation had a sudden arrest rate of 6.7% per year compared with 1.2% and 2.2% per year in the lower tertiles, whereas infarct volume and LVEF did not predict events (Fallavollita 2014).

Mismatch between innervation and perfusion, a region with preserved perfusion and absent MIBG or HED uptake, identifies viable denervated myocardium at the border of an infarct. No randomized trial has used innervation imaging to withhold or allocate a defibrillator, and current defibrillator indications remain based on ejection fraction, NYHA class, and clinical context.

PET tracers of sympathetic innervation

Positron emission tomography offers absolute quantification, attenuation correction, and higher spatial resolution than single-photon imaging. Carbon-11 hydroxyephedrine, the most widely used PET tracer for presynaptic function, is retained by uptake-1 and quantified as a retention index; its 20-minute half-life restricts it to centers with an on-site cyclotron. Carbon-11 epinephrine, which is stored in vesicles, and carbon-11 CGP-12177, which binds postsynaptic beta-receptors, are research tracers. Fluorine-18 flubrobenguane, a benzylguanidine with a 110-minute half-life suited to distribution from a regional cyclotron, gave global and regional innervation measures closely correlated with HED in 25 participants with and without cardiomyopathy (Zelt 2021). None of these tracers is approved for cardiac use in the United States.

MIBG in neurodegenerative disease, diabetes, amyloidosis, takotsubo syndrome, and transplantation

Parkinson disease and dementia with Lewy bodies. Lewy body disorders involve postganglionic cardiac sympathetic neurons early, so cardiac MIBG uptake falls in Parkinson disease and dementia with Lewy bodies, whereas multiple system atrophy and progressive supranuclear palsy, which affect preganglionic or central pathways, preserve it. The fourth consensus report of the Dementia with Lewy Bodies Consortium lists low MIBG uptake on myocardial scintigraphy as an indicative biomarker for dementia with Lewy bodies (McKeith 2017). In a multicenter study of 133 patients, the delayed ratio separated probable dementia with Lewy bodies from probable Alzheimer disease with a sensitivity of 68.9% and a specificity of 89.1%. In mild dementia, sensitivity was 77.4% and specificity 93.8% (Yoshita 2015). A low ratio in a patient with heart failure and parkinsonism therefore has two possible causes.

Diabetes. Cardiac autonomic neuropathy reduces MIBG uptake regionally or globally, and reduced uptake has been associated with mortality in observational cohorts. It is a research measurement; cardiovascular autonomic reflex tests remain the clinical standard.

Amyloidosis. Sympathetic denervation is frequent in hereditary transthyretin and light-chain amyloidosis, and reduced uptake has been reported before bone-avid tracer uptake becomes abnormal in hereditary transthyretin carriers. MIBG does not type amyloid; diagnosis follows the pathway in the cardiac amyloidosis hub.

Takotsubo syndrome and other conditions. In takotsubo syndrome, MIBG uptake is reduced in the dysfunctional apical and midventricular segments, often more extensively than perfusion, and recovers over months. Reduced or heterogeneous uptake has also been described in arrhythmogenic right ventricular cardiomyopathy, Brugada syndrome, idiopathic ventricular tachycardia, hypertrophic cardiomyopathy, and chemotherapy cardiotoxicity (Gimelli 2021). After heart transplantation the graft is denervated; partial, regional reinnervation develops over years, begins at the base and anterior wall, and is associated with recovery of chronotropic response and anginal perception.

Phase analysis of gated SPECT and PET

Method. In a gated perfusion study, the count density of a myocardial sample rises with wall thickening through the partial-volume effect. Phase analysis fits the first harmonic of a Fourier series to the count curve of the sample across the gated frames. The phase of that harmonic, expressed in degrees from 0 to 360 of the R-R interval, marks the onset of mechanical contraction of the sample (Chen 2005). The phases of all samples are displayed as a polar map and as a histogram. A synchronous ventricle produces a narrow, single-peaked histogram; a dyssynchronous ventricle produces a wide histogram, and a ventricle with an aneurysm produces two peaks separated by about 180°.

Indices. Phase standard deviation is the standard deviation of the phase distribution. Histogram bandwidth is the range containing 95% of the samples. Skewness and kurtosis describe the shape of the histogram, and phase entropy describes its disorder. In early validation, bandwidth and phase standard deviation correlated well with tissue Doppler dyssynchrony (r = 0.89 and 0.80), whereas skewness and kurtosis correlated less well (Henneman, JACC 2007). The site of latest mechanical activation is the segment with the latest mean phase and is used for lead targeting.

Acquisition requirements. Phase analysis uses 8 or 16 frames per cycle. The first-harmonic fit resolves phase to about 1/64 of the cycle with either framing. The choice depends on myocardial counts: an 8-frame study carries twice the counts per frame of a 16-frame study and can give the more precise phase measurement when counts are limited (Jimenez-Heffernan 2021). Values depend on frame number, counts, reconstruction, base and apex selection, segmentation, and software; the VISION-CRT technical report describes base and apex selection and gating quality control as major sources of phase artifact (Jimenez-Heffernan 2021). Only normal limits validated for the software in use apply, and serial comparisons use the same software and framing. Phase analysis is also available for gated PET and gated blood-pool studies and does not require extra imaging or radiation.

MeasurementValueSource and context
Phase standard deviation, normalMen 14.2° ± 5.1°; women 11.8° ± 5.2°90 normal subjects, Tc-99m sestamibi gated SPECT, one software package (Chen 2005)
Histogram bandwidth, normalMen 38.7° ± 11.8°; women 30.6° ± 9.6°Same normal database
Phase standard deviation, CRT response cutoff43° (sensitivity and specificity 74%)42 patients with standard CRT indications (Henneman, J Nucl Med 2007)
Histogram bandwidth, CRT response cutoff135° (sensitivity and specificity 70%)Same study
Blood-pool phase indices, normalPhase standard deviation 59.4°; synchrony 0.73; entropy 0.77Planar equilibrium phase analysis, as reported in the 2020 SNMMI/EANM standard

Phase analysis reference values and response cutoffs. Values are specific to the acquisition and software in which they were derived and are not transferable without validation. CRT, cardiac resynchronization therapy.

Phase analysis of the gated blood pool

Phase analysis began with blood-pool imaging, in which first-harmonic analysis of the time–activity curve of individual pixels produces phase and amplitude images. Ventricular pixels empty in systole and atrial pixels fill, so normal ventricles share one phase and the atria lie about 180° away. The phase image localizes the earliest ventricular activation, which made it an early noninvasive method for locating accessory pathways and the origin of ventricular tachycardia. It also displays bundle branch block as progressive phase delay from one ventricle to the other. The SNMMI/EANM standard describes two indices derived from planar blood-pool phase: synchrony, the efficiency of contraction within a region, and entropy, the randomness of phase from 0 for a single phase to 1 for complete dyssynchrony (Farrell 2020). SPECT blood-pool imaging adds three-dimensional phase for both ventricles, including right ventricular synchrony.

Four blood-pool phase images in the left anterior oblique view, each beside its left ventricular phase histogram: a normal ventricle with a narrow single peak; a ventricle after myocardial infarction with a tail of late phases; left bundle branch block with a gradual change in phase across the ventricle; and an aneurysm with two separate peaks about 180 degrees apart.
Phase images from planar radionuclide ventriculography with left ventricular phase histograms. (a) Normal: uniform phase and a narrow histogram. (b) Apical myocardial infarction: late phases in the infarct region widen the histogram. (c) Left bundle branch block: a gradual change of phase across the left ventricle. (d) Large aneurysm: two regions contracting at different times produce two separate peaks. LA, left atrium; LV, left ventricle; MI, myocardial infarction; RA, right atrium; RV, right ventricle. Credit: Jones KA, Small AD, Ray S, et al. J Nucl Cardiol 2022;29:581–589, figure 1, PubMed Central; CC BY 4.0.

Dyssynchrony, selection for resynchronization, and left ventricular lead guidance

Selection for resynchronization. In early single-center studies, patients who responded to resynchronization had wider baseline histograms (bandwidth 175° compared with 117°; phase standard deviation 56.3° compared with 37.1°) (Henneman, J Nucl Med 2007). Larger studies did not confirm baseline mechanical dyssynchrony as a selection tool. In the multicenter VISION-CRT cohort, 195 patients from 10 centers in 8 countries were enrolled and 179 completed follow-up. Of those 179, 84.9% met the composite primary outcome of improvement in NYHA class, LVEF, end-systolic volume, or quality of life. Baseline phase standard deviation was not associated with the outcome (odds ratio 0.66; 95% CI 0.25 to 1.76). In contrast, a 1° reduction in phase standard deviation at 6 months was associated with it (odds ratio 1.04), with an area under the curve of 0.78 (Peix 2021). Echocardiographic dyssynchrony measures also failed to select responders in PROSPECT and EchoCRT. The 2023 Heart Rhythm Society, Asia Pacific Heart Rhythm Society, and Latin American Heart Rhythm Society (HRS/APHRS/LAHRS) guideline assigns Class 3 (No Benefit) to resynchronization in patients with a QRS duration under 120 ms. It assigns the same class to preprocedural echocardiographic dyssynchrony assessment for predicting the outcome of biventricular pacing in any patient being considered for resynchronization (Chung 2023). Selection rests on QRS duration and morphology, as described in the cardiac resynchronization therapy hub. Nuclear phase indices are not part of US selection criteria.

Lead position. Phase analysis identifies the segment of latest mechanical activation and, from the perfusion images, whether that segment is viable. In 90 patients, a left ventricular lead placed at the site of latest activation (concordant) was associated with more responders than a discordant lead (79% and 26%). Patients with a concordant lead improved volumes and ejection fraction at 6 months while those with a discordant lead did not (Boogers 2011). A meta-analysis of 8 studies of image-guided lead placement (echocardiography, magnetic resonance, or nuclear imaging; 1,075 patients, including a randomized SPECT-guided study) found a higher response rate (risk ratio 1.33) and greater reduction in end-systolic volume with guidance. It found no difference in heart failure hospitalization or mortality (Hu 2021). In VISION-CRT, a lead in the viable segment of latest activation was achieved in only 23% and was not associated with outcome (Peix 2021). Targeting the site of latest activation may be considered under the 2023 guideline (Class 2b), and outcome-based randomized trials of electrically targeted placement have been neutral, as summarized in the lead position section of the CRT hub. Image fusion of phase maps with fluoroscopic venography is under study.

Prognostic use of phase dispersion and entropy. Wide phase dispersion on gated SPECT has been associated with death independently of ejection fraction and perfusion in some cohorts (Uebleis 2012) but not in others (Hess 2017). In 3,963 patients undergoing rubidium-82 PET, stress phase entropy added prognostic value to standard perfusion and flow variables (Kuronuma 2023). These measurements are reported as descriptive findings and do not yet carry guideline-defined thresholds. Gated function and its sources of error in perfusion studies are covered in the myocardial perfusion imaging hub.

Reporting blood-pool, innervation, and phase studies

A structured report states the study type and the limitations that change its meaning. For blood-pool imaging, the SNMMI/EANM standard lists as standard elements the labeling technique, radiopharmaceutical and activity, indication, ventricular size and regional wall motion, quantitative LVEF, qualitative diastolic function (with peak filling rate preferred), right ventricular size and motion, and comparison with prior studies. At stress, the report adds the protocol, symptoms, heart rate and blood pressure response, workload, and the change in ejection fraction and wall motion from rest (Farrell 2020).

StudyElements that determine interpretation
Equilibrium radionuclide angiographyLabeling method and quality (free pertechnetate); rhythm, beat histogram, and accepted-beat fraction; frames per cycle; view quality and chamber separation; LVEF with method (planar count-based or SPECT volumetric); regional motion; change from prior study and whether the method was identical
First-pass angiographyInjection site and bolus quality; count rate; right and left ventricular ejection fractions; transit and shunt findings
I-123 MIBGThyroid blockade; interfering medications and neurologic disease; collimator and matrix; injection-to-image times; early and delayed heart-to-mediastinum ratio with region method; washout formula (background and decay correction); SPECT defects and relation to perfusion; comparability with prior studies
Phase analysisSoftware and frame number; phase standard deviation and bandwidth with the software's normal limits; site of latest activation and its viability; gating quality and base-apex selection

Report elements for function, innervation, and phase studies (Farrell 2020; Flotats 2010; Jimenez-Heffernan 2021).

A serial cardio-oncology report states the current and baseline ejection fractions, the absolute change in percentage points, whether the change exceeds the laboratory's reproducibility, and whether the acquisition and processing match those of the baseline study. When the change crosses a threshold that alters cancer therapy, the result is communicated to the treating team, with repeat imaging in 2 to 3 weeks when confirmation is required.

References

  1. Farrell MB, Galt JR, Georgoulias P, et al. SNMMI procedure standard/EANM guideline for gated equilibrium radionuclide angiography. J Nucl Med Technol. 2020;48:126–135. doi:10.2967/jnmt.120.246405
  2. Corbett JR, Akinboboye OO, Bacharach SL, et al. Equilibrium radionuclide angiocardiography. J Nucl Cardiol. 2006;13:e56–e79. doi:10.1016/j.nuclcard.2006.08.007
  3. Friedman JD, Berman DS, Borges-Neto S, et al. First-pass radionuclide angiography. J Nucl Cardiol. 2006;13:e42–e55. doi:10.1016/j.nuclcard.2006.08.006
  4. Hesse B, Lindhardt TB, Acampa W, et al. EANM/ESC guidelines for radionuclide imaging of cardiac function. Eur J Nucl Med Mol Imaging. 2008;35:851–885. doi:10.1007/s00259-007-0694-9
  5. Dorbala S, Ananthasubramaniam K, Armstrong IS, et al. Single photon emission computed tomography (SPECT) myocardial perfusion imaging guidelines: instrumentation, acquisition, processing, and interpretation. J Nucl Cardiol. 2018;25:1784–1846. doi:10.1007/s12350-018-1283-y
  6. Huang H, Nijjar PS, Misialek JR, et al. Accuracy of left ventricular ejection fraction by contemporary multiple gated acquisition scanning in patients with cancer: comparison with cardiovascular magnetic resonance. J Cardiovasc Magn Reson. 2017;19:34. doi:10.1186/s12968-017-0348-4
  7. Thavendiranathan P, Grant AD, Negishi T, et al. Reproducibility of echocardiographic techniques for sequential assessment of left ventricular ejection fraction and volumes: application to patients undergoing cancer chemotherapy. J Am Coll Cardiol. 2013;61:77–84. doi:10.1016/j.jacc.2012.09.035
  8. Plana JC, Galderisi M, Barac A, et al. Expert consensus for multimodality imaging evaluation of adult patients during and after cancer therapy: a report from the American Society of Echocardiography and the European Association of Cardiovascular Imaging. Eur Heart J Cardiovasc Imaging. 2014;15:1063–1093. doi:10.1093/ehjci/jeu192
  9. Herrmann J, Lenihan D, Armenian S, et al. Defining cardiovascular toxicities of cancer therapies: an International Cardio-Oncology Society (IC-OS) consensus statement. Eur Heart J. 2022;43:280–299. doi:10.1093/eurheartj/ehab674
  10. Lyon AR, López-Fernández T, Couch LS, et al. 2022 ESC guidelines on cardio-oncology developed in collaboration with the European Hematology Association (EHA), the European Society for Therapeutic Radiology and Oncology (ESTRO) and the International Cardio-Oncology Society (IC-OS). Eur Heart J. 2022;43:4229–4361. doi:10.1093/eurheartj/ehac244
  11. Armenian SH, Lacchetti C, Barac A, et al. Prevention and monitoring of cardiac dysfunction in survivors of adult cancers: American Society of Clinical Oncology clinical practice guideline. J Clin Oncol. 2017;35:893–911. doi:10.1200/JCO.2016.70.5400
  12. Schwartz RG, McKenzie WB, Alexander J, et al. Congestive heart failure and left ventricular dysfunction complicating doxorubicin therapy: seven-year experience using serial radionuclide angiocardiography. Am J Med. 1987;82:1109–1118. doi:10.1016/0002-9343(87)90212-9
  13. HERCEPTIN (trastuzumab) for injection, for intravenous use. US prescribing information. South San Francisco, CA: Genentech, Inc. DailyMed set ID 492dbdb2-077e-4064-bff3-372d6af0a7a2. dailymed.nlm.nih.gov
  14. Jones KA, Small AD, Ray S, et al. Radionuclide ventriculography phase analysis for risk stratification of patients undergoing cardiotoxic cancer therapy. J Nucl Cardiol. 2022;29:581–589. doi:10.1007/s12350-020-02277-z
  15. ADREVIEW (iobenguane I 123 injection). US prescribing information. Arlington Heights, IL: Medi-Physics, Inc. (GE HealthCare). DailyMed set ID c89d3ecc-4f4c-4566-8808-79152344194d. dailymed.nlm.nih.gov
  16. Jacobson AF, Senior R, Cerqueira MD, et al. Myocardial iodine-123 meta-iodobenzylguanidine imaging and cardiac events in heart failure: results of the prospective ADMIRE-HF (AdreView Myocardial Imaging for Risk Evaluation in Heart Failure) study. J Am Coll Cardiol. 2010;55:2212–2221. doi:10.1016/j.jacc.2010.01.014
  17. Nakata T, Nakajima K, Yamashina S, et al. A pooled analysis of multicenter cohort studies of 123I-mIBG imaging of sympathetic innervation for assessment of long-term prognosis in heart failure. JACC Cardiovasc Imaging. 2013;6:772–784. doi:10.1016/j.jcmg.2013.02.007
  18. Verschure DO, Veltman CE, Manrique A, et al. For what endpoint does myocardial 123I-MIBG scintigraphy have the greatest prognostic value in patients with chronic heart failure? Results of a pooled individual patient data meta-analysis. Eur Heart J Cardiovasc Imaging. 2014;15:996–1003. doi:10.1093/ehjci/jeu044
  19. Flotats A, Carrió I, Agostini D, et al. Proposal for standardization of 123I-metaiodobenzylguanidine (MIBG) cardiac sympathetic imaging by the EANM Cardiovascular Committee and the European Council of Nuclear Cardiology. Eur J Nucl Med Mol Imaging. 2010;37:1802–1812. doi:10.1007/s00259-010-1491-4
  20. Peacock JG, Majot H, Bansal AT, et al. Illuminating the hidden: standardizing cardiac MIBG imaging for sympathetic dysfunction. J Nucl Med Technol. 2025;53:90–100. doi:10.2967/jnmt.124.269436
  21. Okuda K, Nakajima K, Kitamura C, et al. Machine learning-based prediction of conversion coefficients for I-123 metaiodobenzylguanidine heart-to-mediastinum ratio. J Nucl Cardiol. 2023;30:1630–1641. doi:10.1007/s12350-023-03198-3
  22. Gimelli A, Liga R, Agostini D, et al. The role of myocardial innervation imaging in different clinical scenarios: an expert document of the European Association of Cardiovascular Imaging and Cardiovascular Committee of the European Association of Nuclear Medicine. Eur Heart J Cardiovasc Imaging. 2021;22:480–490. doi:10.1093/ehjci/jeab007
  23. Boogers MJ, Borleffs CJ, Henneman MM, et al. Cardiac sympathetic denervation assessed with 123-iodine metaiodobenzylguanidine imaging predicts ventricular arrhythmias in implantable cardioverter-defibrillator patients. J Am Coll Cardiol. 2010;55:2769–2777. doi:10.1016/j.jacc.2009.12.066
  24. Fallavollita JA, Heavey BM, Luisi AJ, et al. Regional myocardial sympathetic denervation predicts the risk of sudden cardiac arrest in ischemic cardiomyopathy. J Am Coll Cardiol. 2014;63:141–149. doi:10.1016/j.jacc.2013.07.096
  25. Zelt JGE, Britt D, Mair BA, et al. Regional distribution of fluorine-18-flubrobenguane and carbon-11-hydroxyephedrine for cardiac PET imaging of sympathetic innervation. JACC Cardiovasc Imaging. 2021;14:1425–1436. doi:10.1016/j.jcmg.2020.09.026
  26. McKeith IG, Boeve BF, Dickson DW, et al. Diagnosis and management of dementia with Lewy bodies: fourth consensus report of the DLB Consortium. Neurology. 2017;89:88–100. doi:10.1212/WNL.0000000000004058
  27. Yoshita M, Arai H, Arai H, et al. Diagnostic accuracy of 123I-meta-iodobenzylguanidine myocardial scintigraphy in dementia with Lewy bodies: a multicenter study. PLoS One. 2015;10:e0120540. doi:10.1371/journal.pone.0120540
  28. Chen J, Garcia EV, Folks RD, et al. Onset of left ventricular mechanical contraction as determined by phase analysis of ECG-gated myocardial perfusion SPECT imaging: development of a diagnostic tool for assessment of cardiac mechanical dyssynchrony. J Nucl Cardiol. 2005;12:687–695. doi:10.1016/j.nuclcard.2005.06.088
  29. Henneman MM, Chen J, Ypenburg C, et al. Phase analysis of gated myocardial perfusion single-photon emission computed tomography compared with tissue Doppler imaging for the assessment of left ventricular dyssynchrony. J Am Coll Cardiol. 2007;49:1708–1714. doi:10.1016/j.jacc.2007.01.063
  30. Henneman MM, Chen J, Dibbets-Schneider P, et al. Can LV dyssynchrony as assessed with phase analysis on gated myocardial perfusion SPECT predict response to CRT? J Nucl Med. 2007;48:1104–1111. doi:10.2967/jnumed.107.039925
  31. Boogers MJ, Chen J, van Bommel RJ, et al. Optimal left ventricular lead position assessed with phase analysis on gated myocardial perfusion SPECT. Eur J Nucl Med Mol Imaging. 2011;38:230–238. doi:10.1007/s00259-010-1621-z
  32. Peix A, Karthikeyan G, Massardo T, et al. Value of intraventricular dyssynchrony assessment by gated-SPECT myocardial perfusion imaging in the management of heart failure patients undergoing cardiac resynchronization therapy (VISION-CRT). J Nucl Cardiol. 2021;28:55–64. doi:10.1007/s12350-018-01589-5
  33. Jimenez-Heffernan A, Butt S, Mesquita CT, et al. Technical aspects of gated SPECT MPI assessment of left ventricular dyssynchrony used in the VISION-CRT study. J Nucl Cardiol. 2021;28:1165–1171. doi:10.1007/s12350-020-02122-3
  34. Hu X, Xu H, Hassea SRA, et al. Comparative efficacy of image-guided techniques in cardiac resynchronization therapy: a meta-analysis. BMC Cardiovasc Disord. 2021;21:255. doi:10.1186/s12872-021-02061-y
  35. Chung MK, Patton KK, Lau CP, et al. 2023 HRS/APHRS/LAHRS guideline on cardiac physiologic pacing for the avoidance and mitigation of heart failure. Heart Rhythm. 2023;20:e17–e91. doi:10.1016/j.hrthm.2023.03.1538
  36. Uebleis C, Hellweger S, Laubender RP, et al. Left ventricular dyssynchrony assessed by gated SPECT phase analysis is an independent predictor of death in patients with advanced coronary artery disease and reduced left ventricular function not undergoing cardiac resynchronization therapy. Eur J Nucl Med Mol Imaging. 2012;39:1561–1569. doi:10.1007/s00259-012-2157-1
  37. Hess PL, Shaw LK, Fudim M, et al. The prognostic value of mechanical left ventricular dyssynchrony defined by phase analysis from gated single-photon emission computed tomography myocardial perfusion imaging among patients with coronary heart disease. J Nucl Cardiol. 2017;24:482–490. doi:10.1007/s12350-015-0388-9
  38. Kuronuma K, Miller RJH, Van Kriekinge SD, et al. Incremental prognostic value of stress phase entropy over standard PET myocardial perfusion imaging variables. Eur J Nucl Med Mol Imaging. 2023;50:3619–3629. doi:10.1007/s00259-023-06323-z